This water heater complies with ANSI Z21.10.1-current
edition regarding the accidental or unintended ignition of
fl ammable vapors, such as those emitted by gasoline.
For Your Safety
AN ODORANT IS ADDED TO THE GAS USED
BY THIS WATER HEATER.
• Safety Instructions
• Installation
• Operation
INSTALLER:
• AFFIX THESE INSTRUCTIONS TO OR ADJACENT
TO THE WATER HEATER.
OWNER:
• RETAIN THESE INSTRUCTIONS AND WARRANTY
FOR FUTURE REFERENCE. RETAIN THE
ORIGINAL RECEIPT AS PROOF OF PURCHASE.
WARNING: Gas leaks can not always be detected by
smell.
Gas suppliers recommend that you use a gas detector
approved by UL or CSA.
For more information, contact the your gas supplier.
If a gas leak is detected, follow the “WHAT TO DO IF YOU
SMELL GAS” instructions.
• Care and Maintenance
• Troubleshooting
• Parts List
WARNING: If the information in these
instructions is not followed exactly, a fire
or explosion may result causing property
damage, personal injury or death.
— Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch;
do not use any phone in your
building.
• Immediately call your gas supplier
from a neighbor’s phone. Follow the
gas supplier’s instructions.
• If you cannot reach your gas supplier, call the fire department.
— Installation and service must be
performed by a qualified installer,
service agency or the gas supplier.
ALL TECHNICAL AND WARRANTY QUESTIONS: SHOULD BE DIRECTED TO THE LOCAL DEALER FROM WHOM THE WATER HEATER WAS PURCHASED.
IF YOU ARE UNSUCCESSFUL, CONTACT RESIDENTIAL TECHNICAL ASSISTANCE AT 1-800-999-9515 OR WWW.AMERICANWATERHEATER.COM.
PRINTED IN THE U.S.A 0410 PART NO. 317994-002
1
TABLE OF CONTENTS
Water Heater Safety ........................................................................................................................................................................... 1-4
Safe Installation, Use and Service ...................................................................................................................................................... 3
Installing Your Gas Water Heater ..................................................................................................................................................... 6-8
Important Information About Your Water Heater ...................................................................................................................... 6
Consumer Information ............................................................................................................................................................. 6
Unpacking the Water Heater ................................................................................................................................................... 6
Site Locations .......................................................................................................................................................................... 7
Clearances and Accessibility ................................................................................................................................................... 8
State of California .................................................................................................................................................................... 8
Gas Supply ....................................................................................................................................................................................... 9-10
Gas Requirements .................................................................................................................................................................... 9
Gas Piping ............................................................................................................................................................................... 9
Gas Pressure ........................................................................................................................................................................... 9
Gas Pressure Testing ............................................................................................................................................................... 9
Gas Pipe Capacity Table ........................................................................................................................................................ 10
Combustion Air and Ventilation ....................................................................................................................................................11-15
Unconfined Space ...................................................................................................................................................................11
Confined Space ......................................................................................................................................................................11
All Air from Inside the Building ............................................................................................................................................... 12
All Air from Outdoors .............................................................................................................................................................. 12
Louvers and Grilles ........................................................................................................................................................... 12-13
Vent Pipe System .................................................................................................................................................................. 13
Vertical Exhaust Gas Vent ................................................................................................................................................ 14-15
Water System Piping ..................................................................................................................................................................... 15-18
Temperature & Pressure Relief Valve ............................................................................................................................... 16-17
T&P Relief Valve and Pipe Installation .................................................................................................................................. 17
Combination Space Heating/Potable Water System ........................................................................................................ 17-18
Solar Installation .................................................................................................................................................................... 18
Electrical Connections and Wiring Diagram .......................................................................................................................... 18
Important Information About this Water Heater ..............................................................................................................................19
Operating Your Water Heater ....................................................................................................................................................... 20-25
Gas Valve/Thermostat - Lighting Instructions ........................................................................................................................ 20
Checking the Draft ................................................................................................................................................................. 21
Water Temperature Regulation ......................................................................................................................................... 22-23
Temperature and Pressure Relief Valve ................................................................................................................................ 25
Maintenance of Your Water Heater .............................................................................................................................................. 25-27
Replacement Parts ................................................................................................................................................................ 25
Removing the Burner from the Manifold/Burner Assembly ................................................................................................... 25
Replacing the Flame Sense/Hot Surface Igniter Assembly ................................................................................................... 26
External Inspection & Cleaning of the Air Intake Chamber Louvers ..................................................................................... 26
Cleaning the Combustion Chamber andAir Diverter Assembly ............................................................................................. 26
Replacing the Manifold Burner/Assembly ......................................................................................................................... 26-27
Removing and Replacing the Gas Control Valve/Thermostat ............................................................................................... 27
FVIR System Operational Checklist ...................................................................................................................................... 28
Control Display Troubleshooting ................................................................................................................................................ 30-33
Repair Parts Illustration ..................................................................................................................................................................... 34
Listed Parts Kits and Illustrations............................................................................................................................................ 35
2
SAFE INSTALLATION, USE AND SERVICE
Your safety and the safety of others is extremely important in the installation, use and servicing of this water heater.
Many safety-related messages and instructions have been provided in this manual and on your water heater to warn you and
others of a potential hazard. Read and obey all safety messages and instructions throughout this manual. It is very important
that the meaning of each safety message is understood by you and others who install, use or service this water heater.
This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety
messages that follow this symbol to avoid possible injury or death.
DANGER indicates an imminently hazardous situation which, if not avoided, will
DANGER
WARNING
CAUTION
CAUTION
All safety messages will generally tell you about the type of hazard, what can happen if you do not follow the safety message
and how to avoid the risk of injury.
The California Safe Drinking Water and Toxic Enforcement Act requires the Governor of California to publish a list of
substances known to the State of California to cause cancer, birth defects, or other reproductive harm, and requires businesses
to warn of potential exposure to such substances.
WARNING: This product contains a chemical known to the State of California to cause cancer, birth defects, or other
reproductive harm.
This appliance can cause low-level exposure to some of the substances included in the Act.
result in death or injury.
WARNING indicates a potentially hazardous situation which, if not avoided, could
result in death or injury.
CAUTION indicates a potentially hazardous situation which, if not avoided, could
result in minor or moderate injury.
CAUTION used without the safety alert symbol indicates a potentially hazardous
situation which, if not avoided, could result in property damage
IMPORTANT DEFINITIONS
• Qualified Technician: A qualified technician must have ability equivalent to a licensed tradesman in the fields of
plumbing, air supply, venting, and gas supply, including a thorough understanding of the requirements of the National
Fuel Gas Code as it relates to the installation of gas fired water heaters. The qualified technician must also be
familiar with the design features and use of flammable vapor ignition resistant water heaters, and have a thorough
understanding of this instruction manual.
• Service Agency: A service agency also must have ability equivalent to a licensed tradesman in the fields of
plumbing, air supply, venting and gas supply, including a thorough understanding of the requirements of the National
Fuel Gas Code as it relates to the installation of gas fired water heaters. The service agency must also have a
thorough understanding of this instruction manual, and be able to perform repairs strictly in accordance with the
service guidelines provided by the manufacturer.
• Gas Supplier: The Natural Gas or Propane Utility or service who supplies gas for utilization by the gas burning
appliances within this application. The gas supplier typically has responsibility for the inspection and code approval of
gas piping up to and including the Natural Gas meter or Propane storage tank of a building. Many gas suppliers also
offer service and inspection of appliances within the building.
FLAMMABLES
SAFETY PRECAUTIONS
WARNING
FIRE AND EXPLOSION HAZARD
Can result in serious injury or death
Do not store or use gasoline or other
flammable vapors and liquids in the vicinity of this
or any other appliance. Storage of or use of
Flammable Vapors
Read and follow water heater warnings and instructions.
gasoline or other flammable vapors or liquids in the
vicinity of this or any other appliance can result in
serious injury or death.
3
Fire or Explosion Hazard
Do not store or use gasoline or other flammable vapors and
liquids in the vicinity of this or any other appliance.
Avoid all ignition sources if you smell Natural or LP gas.
Do not expose water heater control to excessive gas
pressure.
Use only gas shown on rating plate.
Maintain required clearances to combustibles.
Keep ignition sources away from faucets after extended
period of non-use.
Read instruction manual before
installing, using or servicing
water heater.
4
TYPICAL INSTALLATION
GET TO KNOW YOUR WATER HEATER - GAS MODELS
A Vent Pipe
B Draft hood
C Anode (Not Shown)
D Hot Water Outlet
E Insulation
F Gas Supply Piping
G Manual Gas Shut-off Valve
H Ground Joint Union
I Drip Leg (Sediment Trap)
J Inner Door
* INSTALL IN ACCORDANCE
WITH LOCAL CODES.
* DRIP LEG AS REQUIRED
BY LOCAL CODES.
* ALL PIPING MATERIALS
TO BE SUPPLIED BY
CUSTOMERS.
TO VENT TERMINATION
ON ROOF
A
D
R
F
G
H
I
W
B
E
Z
V
U
J
ZZ
INSTALL THERMAL EXPANSION
L
X
S
K Outer door
L Union
M Inlet Water Shut-off Valve
N Cold Water Inlet
O Inlet Dip Tube
P Temperature & Pressure Relief Valve
Q Rating Plate
R Flue Baffl e
S Gas Control Valve/Thermostat
T Drain Valve
TANK IF WATER HEATER IS
INSTALLED IN A CLOSED
WATER SYSTEM
M
N
VACUUM RELIEF
O
Q
T
YY
VALV E
*INSTALL PER
LOCAL CODES
P
DISCHARGE PIPE
(DO NOT CAP OR PLUG.)
FLOOR DRAIN
6” MAXIMUM
AIR GAP
IMPORTANT:
WHEN BRUSHING ON AN
APPROVED NONCORROSIVE
LEAK DETECTION SOLUTION,
DO NOT SPLASH SOLUTION
ONTO ELECTRICAL CONNECTIONS (SEE PAGE 27).
(S) GAS CONTROL VALVE/THERMOSTAT
MANIFOLD TUBE
POWER SUPPLY
TRANSFORMER
CONNECTOR
(U) NATURAL GAS BURNER ASSEMBLY
MANIFOLD DOOR GASKET
MANIFOLD COMPONENT
BLOCK W/ RETAINER CLIP
BURNER
BURNER
FLAME SENSE
HOT SURFACE
IGNITER
MANIFOLD DOOR ASSEMBLY
U Main Burner
V Flue
W Suitable Metal Drain Pan
X Control Display
Y Power Supply Transformer
(
Shown detached from Heater)
YY Pressure Switch
(
Shown detached from Heater)
Z Air Intake Chamber
ZZ FV Sensor (
IGNITER/
FLAME
SENSE
CONNECTOR
MANIFOLD DOOR ASSEMBLY
MANIFOLD
Shown without Bracket)
IGNITER / FLAME SENSE
CONNECTOR WIRE
TUBE
VIEW PORT
IGNITER / FLAME SENSE
CONNECTOR WIRE
PRESSURE
SWITCH/FAN,
FV SENSOR
CONNECTOR
DISPLAY, ANODE
ROD CONNECTOR
MANIFOLD TUBE
Y
IMPORTANT: DO NOT USE AN E XTEN SION CORD TO CONNECT
THE WATER HEATER TO AN ELECTRICAL OUTLET.
K
FIGURE 1.
5
INSTALLING YOUR GAS WATER HEATER
Important Information About This Water Heater
This gas water heater was manufactured to voluntary
safety standards to reduce the likelihood of a flammable
vapor ignition incident. New technology used in meeting
these standards makes this product more sensitive to
installation errors or improper installation environments.
Please review the Installation Checklist found at the end of
the installation instructions section and make any required
installation upgrades or changes.
Consumer Information
This water heater is design-certified by CSA International
as a Category I, non-direct vented water heater which
takes its combustion air either from the installation area or
from air ducted to the unit from the outside.
This water heater must be installed according to all local
and state codes or, in the absence of local and state
codes, the “National Fuel Gas Code”, ANSI Z223.1(NFPA
54)-current edition. This is available from the following:
CSA America, Inc.
8501 East Pleasant Valley Road
Cleveland, OH 44131
National Fire Protection Agency
1 Batterymarch Park
Quincy, MA 02269
Check your phone listings for the local authorities having
jurisdiction over your installation.
Consumer Responsibilities
Unpacking the Water Heater
WARNING
Excessive Weight Hazard
Use two or more people to move and install the water heater.
Failure to do so can result in injury (including back injury).
IMPORTANT: Do not remove any permanent instructions,
labels, or the data label from either the outside of the
water heater or on the inside of water heater panels.
• Remove exterior packaging and place installation components aside.
• Inspect all parts for damage prior to installation and
start-up.
• Completely read all instructions before attempting to
assemble and install this product.
• After installation, dispose of/recycle all packaging
materials.
This manual has been prepared to acquaint you with the
installation, operation, and maintenance of your gas water
heater and provide important safety information in these
areas.
Read all of the instructions thoroughly before attempting
the installation or operation of this water heater.
Do not discard this manual. You or future users of this
water heater will need it for future reference.
Service to the FVIR System should only be performed by a
qualified technician.
Examples of a qualified technician include: licensed
plumbers, authorized gas company personnel, and
authorized service personnel.
IMPORTANT: The manufacturer and seller of this water
heater will not be liable for any damages, injuries, or
deaths caused by failure to comply with the installation and
operating instructions outlined in this manual.
If you lack the necessary skills required to properly install
this water heater, or you have difficulty following the
instructions, you should not proceed but have a qualified
technician perform the installation of this water heater.
Massachusetts code requires this water heater to be
installed in accordance with Massachusetts Plumbing and
Fuel Gas Code 248 CMR Section 2.00 and 5.00.
A rating plate identifying your water heater can be found
on the front of your water heater. When referring to your
water heater, always have the information listed on the
rating plate readily available. Retain your original receipt
as proof of purchase.
6
Location Requirements
WARNING
Carbon Monoxide Poisoning Hazard
Do not install in a mobile home.
Doing so can result in carbon monoxide poisoning and death.
The FVIR System is designed to reduce the risk of
flammable vapor-related fires. Flammable liquids (such as
gasoline, solvents, propane, etc,) emit flammable vapors
which can be ignited by a gas water heater’s hot surface
igniter or main burner. The resulting flashback and fire can
cause death or serious burns to anyone in the area.
FIGURE 1A.
FV Sensor
This heater is equipped with a FV sensor for detecting the
presence of flammable vapors. When the sensor detects
those vapors, the unit will shut down and not operate.
Should this happen, please refer to the troubleshooting
guide on pages 31-32 (numbers 9,11,12). Even though this
water heater is a flammable vapors ignition resistant water
heater and is designed to reduce the chances of flammable vapors being ignited, gasoline and other flammable
substances should never be stored or used in the same
vicinity or area containing a gas water heater or other open
flame or spark producing appliance.
WARNING
FLAMMABLES
FIRE AND EXPLOSION HAZARD
Can result in serious injury or death
Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any other
appliance. Storage of or use of gasoline or other
flammable vapors or liquids in the vicinity of this or
any other appliance can result in serious injury or
death.
Read and follow water heater warnings and
instructions
Do not use or store flammable products such as gasoline,
solvents, or adhesives in the same room or area near the
water heater. If such flammables must be used, all gas
burning appliances in the vicinity must be shut off and their
pilot lights extinguished. Open the doors and windows for
ventilation while flammable substances are in use.
Flammable Vapors
If flammable liquids or vapors have spilled or leaked in
the area of the water heater, leave the area immediately
and call the fire department from a neighbor’s home. Do
not attempt to clean the spill until all ignition sources have
been extinguished.
WARNING
Fire or Explosion Hazard
• Read instruction manual before installing, using or
servicing water heater.
• Improper use may result in fire or explosion.
• Maintain required clearances to combustibles.
Keep combustibles such as boxes, magazines, clothes, etc. away
from the water heater area.
Site Location
• Select a location near the center of the water piping
system. The water heater must be installed indoors
and in a vertical position on a level surface. DO NOT
install in bathrooms, bedrooms, or any occupied room
normally kept closed.
• Locate the water heater as close to the chimney or gas
vent as practical. Consider the vent system piping and
combustion air supply requirements when selecting the
water heater location. The venting system must be able
to run from the water heater to termination with minimal
length and elbows.
• Locate the water heater near the existing gas piping.
If installing a new gas line, locate the water heater to
minimize the pipe length and elbows.
• The water heater should be located in an area not
subject to freezing temperatures. Water heaters
located in unconditioned spaces (i.e., attics,
basements, etc.) may require insulation of the water
piping and drain piping to protect against freezing.
The drain and controls must be easily accessible for
operation and service. Maintain proper clearances as
specified on the water heater.
• Do not locate the water heater near an air-moving
device. The operation of air-moving devices such
as exhaust fans, ventilation systems, clothes dryers,
fireplaces, etc., can affect the proper operation of the
water heater. Special attention must be given to conditions these devices may create. Flow reversal of flue
gases may cause an increase of carbon monoxide
inside of the dwelling (Figure 1).
• The water heater is to be located as close as possible
to a 120VAC outlet. NOTE: all electrical wiring should
be in accordance to the NEC and all local/state
electrical codes (extension cord is not allowed).
NOTE: This water heater must be installed according to all
local and state codes or, in the absence of local and state
codes, the “National Fuel Gas Code”, ANSI Z223.1(NFPA
54)-current edition and the “National Electrical Code”, ANSI/
NFPS 70 current edition.
7
IMPORTANT: The water heater should be located in an area
where leakage of the tank or connections will not result in
damage to the area adjacent to the water heater or to lower
floors of the structure. Due to the normal corrosive action of
water, the tank will eventually leak after an extended period
of time. Also any external plumbing leak, including those
from improper installation, may cause early failure of the
tank due to corrosion if not repaired. If the homeowner is
uncomfortable with making the repair a qualified technician
should be contacted. A suitable metal drain pan should be
installed under the water heater as shown below, to help
protect the property from damage which may occur from
condensate formation or leaks in the piping connections
or tank. The pan must limit the water level to a maximum
depth of 1-3/4” and be two inches wider than the heater and
piped to an adequate drain. Locate the water heater near a
suitable indoor drain. Outside drains are subject to freezing
temperatures which can obstruct the drain line. The piping
should be at least 3/4” ID and pitched for proper drainage.
FIGURE 1B.
1-3/4”
max.
Pipe to an
adequate drain
EXHAUST FAN
REVERSE FLOW
OF GASES
FIGURE 2.
Clearances and Accessibility
NOTE: Minimum clearances from combustible materials
are stated on the label on the front of the heater adjacent
to the gas control valve/thermostat of the water heater.
The water heater is certified for installation on a
combustible floor.
• IMPORTANT: If installing over carpeting, the carpeting
must be protected by a metal or wood panel beneath
the water heater. The protective panel must extend
beyond the full width and depth of the water heater by
at least five inches (127mm) in any direction; or if in an
alcove or closet installation, the entire floor must be
covered by the panel.
• Figure 2A may be used as a reference guide to locate
the specific clearance locations. A minimum of 5 inches of front clearance should be provided for inspection
and service.
6” min. at
Single Wall
12” min.
Top to
Ceiling
Vent Pipe
At least 2” greater
than the water heater.
Water heater life depends upon water quality, water usage,
water temperature and the environment in which the
water heater is installed. Water heaters are sometimes
installed in locations where leakage may result in property
damage, even with the use of a metal drain pan piped to a
drain. However, unanticipated damage can be reduced or
prevented by a leak detector or water shut-off device used
in conjunction with a piped metal drain pan. These devices
are available from some plumbing supply wholesalers and
retailers, and detect and react to leakage in various ways:
• Sensors mounted in the metal drain pan that trigger an
alarm or turn off the incoming water to the water heater
when water is detected.
• Sensors mounted in the metal drain pan that turn off
the water supply to the entire home when water is
detected in the metal drain pan.
• Water supply shut-off devices that activate based on
the water pressure differential between the cold water
and hot water pipes connected to the water heater.
• Devices that will turn off the gas supply to a gas water
heater while at the same time shutting off its water
supply.
0” min.
Back
0” min.
Sides
0” min.
Air Inlet
Chamber
5” min.
Front
Top View
Minimum Clearance Locations
FIGURE 2A.
State of California
NOTE: The water heater must be braced, anchored, or
strapped to avoid moving during an earthquake. Contact
local utilities for code requirements in your area, visit http://
www.dsa.dgs.ca.gov, or call 1-916-445-8100 and request
instructions.
8
GAS SUPPLY
WARNING
Explosion Hazard
• Use a new CSA approved gas supply line.
• Install a shut-off valve.
• Do not connect a natural gas water heater to an L.P. gas
supply.
• Do not connect an L.P. gas water heater to a natural gas
supply.
• Failure to follow these instructions can result in death,
explosion, or carbon monoxide poisoning.
Gas Requirements
IMPORTANT: Read the rating plate to be sure the water
heater is made for the type of gas you will be using in
your home. This information will be found on the rating
plate located near the gas control valve/thermostat. If the
information does not agree with the type of gas available,
do not install or light. Call your dealer.
NOTE: An odorant is added by the gas supplier to the gas
used by this water heater. This odorant may fade over an
extended period of time. Do not depend upon this odorant
as an indication of leaking gas.
Gas Piping
The gas piping must be installed according to all local and
state codes or, in the absence of local and state codes, the
“National Fuel Gas Code”, ANSI Z223.1(NFPA 54)-current
edition.
Tables 1 and 2 on the following page provide a sizing
reference for commonly used gas pipe materials. Consult
the “National Fuel Gas Code” for the recommended gas
pipe size of other materials.
NOTE: Use pipe joint compound or teflon tape marked as
being resistant to the action of petroleum [Propane (L.P.)]
gases (See Figure 3.)
1. Install a readily accessible manual shut-off valve in the
gas supply line as recommended by the local utility.
Know the location of this valve and how to turn off the
gas to this unit.
2. Install a drip leg (if not already incorporated as part of
the water heater) as shown. The drip leg must be no
less than three inches long for the accumulation of dirt,
foreign material, and water droplets.
3. Install a ground joint union between the gas control
valve/thermostat and the manual shut-off valve. This
is to allow easy removal of the gas control valve/
thermostat.
4. Turn the gas supply on and check for leaks. Test all
connections by brushing on an approved noncorrosive
leak-detection solution. Bubbles will show a leak.
Correct any leak found.
Manual Gas
Shut-Off Valve
Ground Joint Union
Install a readily accessible manual shut-off
valve in the gas supply
line as recommended
by the local utility.
Check with local utility
for minimum height.
3” Minimum
Drip Leg
FIGURE 3.
Discharge Pipe
(Do Not plug or cap)
6” Max. Air Gap
Suitable Drain
Gas Pressure
WARNING
Explosion Hazard
• Gas leaks can not always be detected by smell.
• Gas suppliers recommend that you use a gas
detector approved by UL or CSA.
• For more information, contact your gas supplier.
• If a gas leak is detected, follow the “What to do if you
smell gas” instructions on the cover of this manual.
IMPORTANT: The gas supply pressure must not exceed the
maximum supply pressure as stated on the water heater’s rating
plate. The minimum supply pressure is for the purpose of input
adjustment.
Gas Pressure Testing
IMPORTANT: This water heater and its gas connection must
be leak tested before placing the appliance in operation.
• If the code requires the gas lines to be tested at a
pressure exceeding 14” W.C., the water heater and its
manual shut-off valve must be disconnected from the gas
supply piping system and the line capped.
• If the gas lines are to be tested at a pressure less than
14” W.C., the water heater must be isolated from the gas
supply piping system by closing its manual shut-off valve.
NOTE: Air may be present in the gas lines and could prevent
the burner from lighting on initial start-up. The gas lines should
be purged of air by a qualified technician after installation of
the gas piping system. While purging the gas piping system
of air, insure that the fuel is not spilled in the area of the
water heater installation, or any source of ignition (NOTE:
spilled fuel may trip the FV Sensor preventing heater from
starting). If the fuel is spilled while purging the piping
system of air follow the “WHAT TO DO IF YOU SMELL
GAS” instructions on the cover of this manual.
9
Gas Pipe Capacity Table
WARNING
Explosion Hazard
• Use a new CSA approved gas supply line.
• Install a shut-off valve.
• Do not connect a natural gas water heater to an L.P. gas
supply.
• Do not connect an L.P. gas water heater to a natural gas
supply.
• Failure to follow these instructions can result in death,
explosion, or carbon monoxide poisoning.
WARNING
Explosion Hazard
• Gas leaks can not always be detected by smell.
• Gas suppliers recommend that you use a gas
detector approved by UL or CSA.
• For more information, contact your gas supplier.
• If a gas leak is detected, follow the “What to do if you
smell gas” instructions on the cover of this manual.
10
COMBUSTION AIR & VENTILATION
WARNING
Carbon Monoxide Warning
Water heater must be vented to outdoors.
Vent must be installed by a qualified technician using
the installation instructions.
Examples of a qualified technican include: gas
technicians, authorized gas company personel, and
authorized service persons.
Failure to so do can result in death or carbon monoxide
poisoning.
IMPORTANT: Air for combustion and ventilation must not
come from a corrosive atmosphere. Any failure due to
corrosive elements in the atmosphere is excluded from
warranty coverage.
The following types of installation (not limited to the
following) will require outdoor air for combustion due to
chemical exposure and may reduce but not eliminate the
presence of corrosive chemicals in the air:
• beauty shops
• photo processing labs
• buildings with indoor pools
• water heaters installed in laundry, hobby, or craft
rooms
• water heaters installed near chemical storage areas
Combustion air must be free of acid-forming chemicals such
as sulfur, fluorine, and chlorine. These elements are found
in aerosol sprays, detergents, bleaches, cleaning solvents,
air fresheners, paint, and varnish removers, refrigerants,
and many other commercial and household products. When
burned, vapors from these products form highly corrosive acid
compounds. These products should not be stored or used
near the water heater or air inlet.
Combustion and ventilation air requirements are determined
by the location of the water heater. The water heater may
be located in either an open (unconfined) area or in a
confined area or small enclosure such as a closet or small
room. Confined spaces are areas with less than 50 cubic
feet for each 1,000 BTUH of the total input for all gas-using
appliances.
Unconfined Space
A water heater in an unconfined space uses indoor air for
combustion and requires at least 50 cubic feet for each
1,000 BTUH of the total input for all gas appliances. The
table below shows a few examples of the minimum square
footage (area) required for various BTUH inputs.
TABLE 3
Minimum
BTUH Input
30,0001889 x 21
45,00028114 x 20
60,00037515 x 25
75,00046915 x 31
90,00056320 x 28
105,00065720 x 33
120,00075025 x 30
135,00084428 x 30
IMPORTANT:
• The area must be open and be able to provide the
proper air requirements to the water heater. Areas that
are being used for storage or contain large objects
may not be suitable for water heater installation.
• Water heaters installed in open spaces in buildings
with unusually tight construction may still require outdoor air to function properly. In this situation, outside
air openings should be sized the same as for a confined space.
• Modern home construction usually requires supplying
outside air into the water heater area.
Square
Feet with
8’ Ceiling
Typical Room
with 8’ Ceiling
Confined Space
For the correct and proper operation of this water heater,
ample air must be supplied for the combustion, ventilation,
and dilution of flue gases. Small enclosures and confined
areas must have two permanent openings so that sufficient
fresh air can be drawn from outside of the enclosure. One
opening shall be within 12 inches of the top and one within
12 inches of the bottom of the enclosure as shown in
Figure 4.
The size of each opening (free area) is determined by the
total BTUH input of all gas utilization equipment (i.e., water
heaters, furnaces, clothes dryers, etc.) and the method by
which the air is provided. The BTUH input can be found
on the water heater rating plate. Additional air can be
provided by two methods:
1. All air from inside the building.
2. All air from outdoors.