American Standard T385.5XX User Manual

Installation
Instructions
Reliant 3
T385.5XX
BATH AND SHOWER TRIM KITS
with EverClean™ Finish
Congratulations on purchasing your American Standard faucet with EverClean finish found only on American Standard faucets.
EverClean Finish
• One wipe effortlessly removes spots.
• Eliminates the need for cleaners and scrubbing.
• Permanent surface protectant remains beautiful for the life of the faucet.
To ensure that your installation proceeds smoothly-please read these instructions carefully before you begin.
Required Tools
Phillips Screwdriver
ROUGHING-IN DIMENSIONS
To assure proper positioning in relation to wall, note roughing-in dimensions.
FINISHED WALL
4-1/4" REF.
"SEE ILLUSTRATION "
74" FOR HEAD CLEARANCE
18" OPTIONAL
TOP OF TUB RIM
Flat Blade Screwdriver
6" REF.
5-1/2" REF.
3/4"" TO 2-3/8"
OPTIONAL TO FINISHED
FLOOR USUALLY
BETWEEN 65'' AND 80''
SHR
7-5/8”
TUB
1-1/2" REF.
1/2" COPPER
Plumbers' Putty or Caulking
3-3/8"
3-3/8"
OUTLETS 1/2" NPT
4"
SHR. 1/2" NOM.
COPPER SWEAT
SWEAT INLETS
TUB 1/2" NOM.
COPPER SWEAT
SWEAT INLETS (STOPS)
SHR. 1/2" NOM.
COPPER SWEAT
TUB 1/2" NOM. COPPER SWEAT
INLETS 1/2" NPT
Channel Locks
INLETS
4-1/16"
5-7/8"
3-3/8"
Certified to comply with ANSI A112.18.1
M968898
Teflon Tape
INLETS 1/2" NOM. COPPER SWEAT
2"
4-1/16"
4-1/16"
INLETS 1/2" NOM. COPPER SWEAT
OUTLETS 1/2" NPT
5-7/8"
INLETS
BOTTOM OF TUB
THREADED INLETS
THREADED INLETS (STOPS)
EverClean™ Finish Care Instructions
American Standard’s EverClean finish will wipe clean with a soft, dry cloth. A soft cloth with clean water may also be used, if desired. No additional cleaning products are required.
DO NOT USE: Soaps, acid, polish, abrasives, harsh cleaners, or a cloth with a coarse surface.
INSTALL TRIM
1
13
When finished tiling the wall, remove PLASTER GUARD (3). Push on CAP (1).
Mount ESCUTCHEON (2) and with SCREWS (7).
Install HANDLE (8) by pushing it onto CARTRIDGE STEM (9) and tightening SET SCREW (10) from below with 2.5mm Hex Wrench supplied. Insert INDEX BUTTON (11).
Remove cap from tub supply and plug from shower pipe.
Install SHOWER ARM (4) and FLANGE (13).
Tighten SET SCREW (12) onto FLANGE (13) using 5/64” hex wrench.
Install SHOWER HEAD (5) onto SHOWER ARM (4).
Install DIVERTER SPOUT (6).
ADJUST HOT LIMIT STOP
2
1-1/2" REF.
12
4
3
5
2
9
7
1
8
10
11
6
HOT LIMIT SAFETY STOP ADJUSTMENT
By restricting handle rotation and limiting the amount of hot water allowed to mix with the cold, the HOT LIMIT SAFETY STOP reduces risk of accidental scalding. To set the maximum hot water temperature of your faucets, all you need to do is adjust the setting on the HOT LIMIT SAFETY STOP.
Use a flat blade screwdriver or your fingers to pull up and rotate red HOT LIMIT SAFETY STOP (1). Follow Step "A" or "B" to adjust min./max. discharge temperature. "0" being the hottest to "7" the coldest temperature setting. Factory set at "0".
"A"
ADJUSTMENT WHEN WATER IS TOO HOT
TEMPERATURE SETTING NUMBERS
"B"
ADJUSTMENT WHEN WATER IS TOO COLD
PRY RED RING FORWARD AND ROTATE CLOCKWISE
"B"
0
1
2
3
4
5
6
"A"
PRY RED RING FORWARD AND ROTATE
COUNTER-CLOCKWISE ONE CLICK
1
"RED RING"- HOT LIMIT SAFETY STOP
SERVICE
3
If faucet drips, operate handle several times from "off" to "on". Do not apply excessive force.
Clogged CARTRIDGE (4) inlets may cause reduced flow in "full on" hot or cold. To clean inlets, first turn off water supply, then:
4
2
3
1
Remove HANDLE (1), CAP (2) and CARTRIDGE (4). Clean inlets and MANIFOLD (5). Reassemble CARTRIDGE (4), alternately tightening SCREWS (3). Replace CAP (2) and HANDLE (1). Check flow.
5
M968898