American Standard T373.742, T373.740, T373.741 User Manual

Page 1
Installation
Instructions
ENFIELD
BATH/SHOWER TRIM KITS
Thank you for selecting American-Standard...the benchmark of fine quality for over 100 years.
T373.742 T373.741 T373.740
To ensure that your installation proceeds smoothly--please read these instructions carefully before you begin.
ATTENTION:
If TRIM T373.742 or diverter tub spout is used make sure TWIN ELL (B) P/N 8888.120 is connected to valve body as indicated in roughing­in sketch.
TWIN ELL
TWIN ELL P/N 8888.120 can be ordered as shown in the American Standard List Price Book
ROUGHING-IN DIMENSIONS Installation for Bath/Shower, Shower only, or Valve only Trim.
Dimensions are for reference.
FINISHED WALL
1/2" NPT
1" MIN.
5-1/8" REF.
INSTALL
1
TRIM
When finished tiling the wall, remove PLASTER GUARD (A) and turn off water supply.
Attach STEM ADAPTER (1) to TEMPERATURE CONTROL (2) valve stem with SELF TAPPING SCREW (3). Attach HANDLE SCREW (4) to VOLUME CONTROL ADAPTER (5).
Push CAPS (6) onto TEMPERATURE CONTROL (2) and VOLUME CONTROL ADAPTER (5).
Mount ESCUTCHEON (7) to valve body with SCREWS (8).
Push DIAL PLATE (9) over CAPS (6) and into the four alignment holes in ESCUTCHEON (7) and snap into place.
Remove PIPE CAP (10) and PIPE CAP (11) from shower pipe and tub filler pipe.
Install SHOWER ARM (17) with SHOWER ARM ESCUTCHEON (18), SHOWER HEAD (12) and TUB FILLER SPOUT (13) by threading onto pipe nipples. Use teflon tape or pipe sealant on pipe threads.
Certified to comply with ANSI A112.18.1
M968294 REV 1.1
CAUTION: Protect finish on SHOWER ARM, SHOWER HEAD and TUB SPOUT when installing.
18
9-1/2"
4"
1/2" NPT
Required Tools
Phillips Screwdriver
Adjustable Wrench
7-7/8" REF.
4"
18" OPTIONAL
1" MIN.
5-3/4" REF.
BOTTOM OF TUB
OPTIONAL TO FINISHED
FLOOR USUALLY
BETWEEN 74'' AND 80''
FOR HEAD CLEARANCE
TOP OF TUB RIM
Flat Blade Screwdriver
Channel Locks
TWIN ELL (B)
11
10
17
12
5
4
2
3
1
8
13
PLASTER GUARD (A)
6
7
TOP
(4) ALIGNMENT
HOLES FOR DIAL PLATE
9
Page 2
INSTALL HANDLES
2
Align CROSS HANDLE (1) and push onto VOLUME CONTROL ADAPTER (2). Tighten set screw in CROSS HANDLE (1) securley with HEX WRENCH (3) supplied.
Align LEVER HANDLE (4) and push onto TEMPERATURE CONTROL ADAPTER (5). Tighten set screw in LEVER HANDLE (4) securley with HEX WRENCH (3) supplied.
2
1
4
5
CHECK STOP
(BLUE TO RED)
TRANSPOSED SUPPLY PIPING OR BACK TO BACK INSTALLATION
3
Should the hot and cold water supply pipes have been transposed making
3
adjustment impossible, proceed as follows:
Shut off water supply. Remove handle and rim
Remove check stops and re-install them transposed.
Important note: RED CHECK STOP is now on the right of the mixer body and the BLUE CHECK STOP is now on the left.
Turn the water supply back on and perform the temperature adjustment in step 2.
TEMPERATURE ADJUSTMENT
4
Loosen set screw in LEVER HANDLE ASSEMBLY (1) with HEX WRENCH (2) supplied and pull off LEVER HANDLE ASSEMBLY (1).
Check that arrow marking B points vertically upward. If not, push the BLACK CLAMP on the SECURING RING to the right, pull off KNOB MOUNT (3) and reinstall KNOB MOUNT (3) with arrow "B" vertically upward. See Figure 1.
SET HOT LIMIT STOP
The maximum mixed water temperature is set at 109 F at the factory. This setting can be changed if desired.
Remove the TEMPERATURE LIMIT STOP (H shaped Black Plastic part). Reinstall it at the desired notch as indicated in the diagram to limit the maximum mixed water temperature to 104 F or 112 F.
For 100 F adjustment, turn the water supply on. Turn KNOB MOUNT (3) until the spout temperature is 100 F. Check that arrow "A" on the KNOB MOUNT (3) still points vertically upward after adjusting the thermostat to 100 F. If not, pull out the RED LOCKING DEVICE. Remove KNOB MOUNT (3) by pulling it towards you while standing directly in front of the valve.
Reinstall the KNOB MOUNT (3) with arrow marking "A" vertically upward.
Reinstall RED LOCKING DEVICE.
CHECK STOP
(RED TO BLUE)
ARROWS AT 12 O'CLOCK
POSITION
(Vertically Upward)
3
Figure 1
BLACK CLAMP
ARROW
"B"
104
109
112
TEMPERATURE
LIMIT STOP
RED LOCKING
DEVICE
KNOB MOUNT
ARROW
"A"
2
3
1
CARE INSTRUCTIONS:
DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.
DO NOT: CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A CLOTH WITH A COARSE SURFACE
M968294 REV 1.1
Page 3
ESCUTCHEON AND SCREWS
M962365-YYY0A
M962289-YYY0A
SHOWER ARM AND ESCUTCHEON
ENFIELD
BATH/SHOWER
MODEL NUMBER
T373.742 T373.741 T373.740
M953565-YYY0A
SHOWER HEAD
M909625-YYY0A
DIAL PLATE
M918318-0070A
HANDLE SCREW
907090-YYY0A
ESCUTCHEON CAP
ESCUTCHEON SCREWS
M950220-YYY0A
DIVERTER SPOUT (IPS)
M950119-YYY0A
CROSS HANDLE ASSEMBLY
A918434-YYY0A
M950118-YYY0A
LEVER HANDLE ASSEMBLY
M918990-0070A
SELF TAPPING HANDLE SCREW
M918038-0070A
HANDLE ADAPTER
M962256-YYY0A
DIVERTER SPOUT REPAIR KIT
For toll-free information and answers to your questions, call:
IN CANADA 1-800-387-0369 (TORONTO 1-905-306-1093)
Product names listed herein are trademarks of American Standard Inc. © American Standard Inc. 2003
HOT LINE FOR HELP
1-800 442-1902
Weekdays 8:00 a.m. to 8:00 p.m. EST
Weekdays 8:00 a.m. to 7:00 p.m. EST
Replace the "YYY" with appropriate finish code
CHROME POLISHED NICKEL BLACKENED BRONZE POLISHED BRASS SATIN
002 008 068 099 295
M968294 REV 1.1
Page 4
T
O
P
3/4" C ENTRAL THERM OSTAT WITH V OLUME CONTRO L
Installation
Instructions
M 9 6 8 4 8 0
R540
Thank you for selecting American-Standard...the benchmark of fine quality for over 100 years.
To ensure that your installation proceeds smoothly--please read these instructions carefully before you begin.
Certified to comply with ANSI A112.18.1M ASSE 1016
ROUGHING-IN DIMENSIONS
CONNECTIONS ARE: 3/4" NPT
5-7/8
II II
3-15/16
7
3-5/8
3/4" NPT TUB
3/4" NPT INLET
3/4" NPT INLET
3/4" NPT SHOWER
IMPORTANT: WHEN NOT USING A DIVERTER SPOUT A SEPARATE DIVERTER VALVE MUST BE USED.
NOTE: MINIMUM FLOWING PRESSURE REQUIRED FOR THIS SYSTEM OPERATING WITH ONE SHOWER HEAD AND 2 BODY SPRAYS IS 40 PSI
TUB PORT MUST BE PLUGGED
HOT
3/4" 3/4"
COLD
TUB PORT MUST BE PLUGGED
HOT
3/4" 3/4"
COLD
THERMOSTATIC BATH/ SHOWER INSTALLATION USING A TWIN ELL, DIVERTER SPOUT AND FIXED SHOWER
THERMOSTATIC SHOWER INSTALLATION USING A DIVERTER VALVE, FIXED SHOWER HEAD AND ADJUSTABLE HAND HELD SHOWER
THERMOSTATIC SHOWER INSTALLATION USING A DIVERTER VALVE, FIXED SHOWER HEAD, ADJUSTABLE HAND HELD SHOWER, ON/OFF VALVE AND TWO BODY SPRAYS
TWIN
ELL
TOP OF TUB RIM
BOTTOM OF TUB
TUB PORT
MUST BE
PLUGGED
DIVERTER
VALVE
DIVERTER
VALVE
ON/OFF
VALVE
C/L
4"
18"
(OPTIONAL)
80"-86"
6-1/4
1-5/8 - 2-1/2
Page 5
T
O
P
TEMPERATURE ADJUSTMENT
2
WARNING
Prepare water supplies per ROUGHING-IN DIMENSIONS. Make sure the finished wall is between the minimum and maximum rough dimension.
1
ROUGHING-IN THE VALVE
Install VALVE at indicated height and depth. Make sure the "TOP" marking on the PLASTER GUARD is up.
Connect the hot and cold water supplies. Assemble all connecting pipes. Flush lines to remove any dirt. Connections are 3/4" NPT.
Assemble the connection pipe to one of the MIXED OUTLETS of the VALVE. Cap the other MIXED OUTLET. (Tub port is fitted with a plug at the factory).
IMPORTANT! INSTALL ANY REQUIRED SHUT OFF OR DIVERTER VALVES INTO THE PIPING SYSTEM.
DO NOT SOLDER DIRECTLY TO THE VALVE BODY; THIS WILL DAMAGE THE TEMPERATURE CONTROL ELEMENT AND CHECK STOP VALVES.
Unscrew PLASTER GUARD SCREWS and remove PLASTER GUARD.
Check that arrow marking B points vertically upwards. If not, push the BLACK CLAMP on the SECURING RING to the right, pull off KNOB MOUNT and reinstall KNOB MOUNT with arrow "B" pointing upwards.
For 100 F adjustment, turn the water supply on. Turn KNOB MOUNT until the spout temperature is 100 F. Check that arrow marking A on the KNOB MOUNT still points upward after adjusting the thermostat to 100 F. If not, pull out the RED LOCKING DEVICE. Remove KNOB MOUNT by pulling it towards you while standing directly in front of the valve.
Reinstall the KNOB MOUNT so that the arrow marking A points upwards.
The maximum mixed water temperature is set at 109 F at the factory. This setting can be changed if desired.
Remove the TEMPERATURE LIMIT STOP (H shaped Black Plastic part). Reinstall it at the desired notch as indicated in the diagram to limit the maximum mixed water temperature to 104 F or 112 F.
Reinstall RED LOCKING DEVICE.
KNOB
MOUNT
ARROW
"A"
BLACK CLAMP
ARROW
"B"
RED LOCKING
DEVICE
SECURING
RING
104
109
112
TEMPERATURE
LIMIT STOP
T
O
P
CHECK STOP
(HOT RED)
PLUG
TUB
PORT
CHECK STOP (COLD BLUE)
COLD
HOT
3
2
4
WOOD BRACE
5
6
If the CHECK STOPS (4, 5) were removed during installation, ensure the hot and cold CHECK STOPS (4, 5) are not reversed. The hot CHECK STOP (4) has a red top and the cold CHECK STOP (5) has a blue top.
CHECK STOPS (4,5) are supplied in the open position. Closing using 5/32" (4 mm) hex wrench to pressure test and to check for leaks.
Reassemble PLASTER GUARD (2) and FINISH WALL.
Beware of Freezing. No water should remain in the MIXING VALVE if freezing is a possibility. Remove the CHECK STOPS (4,5) to completely drain the MIXER UNIT (1).
Remove PLASTER GUARD (2) if still installed. Turn on water supplies and check for leaks.
To flush lines, remove the CHECK STOPS (4,5) and run water. If desired, the TEMPERATURE CONTROL UNIT can be removed. Reinstall CHECK STOPS (4,5) and CONTROL UNIT (6), if it was removed.
MIXED
PLUG TUB
PORT
COLD
Should the hot and cold water supply pipes have been transposed making adjustment impossible, proceed as follows:
TRANSPOSED SUPPLY PIPING OR BACK TO BACK INSTALLATION
3
Remove check stops and re-install them transposed.
Shut off water supply. Remove handle and rim
CHECK STOP
(RED TO BLUE)
Important note: RED CHECK STOP is now on the right of the mixer body and the BLUE CHECK STOP is now on the left.
Turn the water supply back on and perform the temperature adjustment in step 2.
CHECK STOP
(BLUE TO RED)
HOT
1
Page 6
3/4" C ENTRAL THERM OSTAT
WITH V OLUME CONTRO L
MODEL NUMBER
M 9 6 8 4 8 0M 9 6 8 4 8 0
R540
HOT LINE FOR HELP
For toll-free information and answers to your questions, call:
1-800 442-1902
Weekdays 8:00 a.m. to 8:00 p.m. EST
IN CANADA 1-800-387-0369 (TORONTO 1-905-306-1093)
Weekdays 8:00 a.m. to 7:00 p.m. EST
Pr od uct n am es li s te d he r ei n ar e t ra de mar ks o f A me ri can S t an da rd In c. © Am eri ca n Sta nd a rd I nc . 2 00 3
923348-0070A
HANDLE ADAPTER
A994352-0070A
CARTRIDGE
954040-0070A
THERMOSTAT
CARTRIDGE
912647-0070A
O-RING
953963-0070A
HANDLE EXTENSION
953957-0070A
TEMPERATURE CALIBRATION UNIT
A953971-0070A
CHECK STOP (COLD BLUE)
A953972-0070A
CHECK STOP (HOT RED)
918428-0070A
CARTRIDGE SCREW
9 6 3 4 3 4 - Y Y Y 0 A D E E P R O U G H K I T ( S O L D S E PAR ATE LY )
912647-0070A
O-RING
Loading...