American Standard Moments T506.60X User Manual

Page 1
AMrieoM Skmiofd
Installation
Instructions

MOMENTS

T506.60X
BATH/SHOWER TRIM KIT WITH DIVERTER
Congratulations on purchasing your American Standard faucet with EverClean™ finish a features found only on American Standard faucets.
• One wipe effortlessly removes spots
• Eliminates the need for cleaners and scrubbing
• Permanent surface protectant remains beautiful
for the life of the faucet
• EverClean™ available on: Polished Chrome, Satin Nickel, Stainless Steel, Polished Brass (or any combination of these finishes)
To ensure that your installation proceeds smoothly-please read these instructions carefully before you begin.
Recommended Tools
Flat Blade Screwdriver
^03
Pipe Wrench
ROUGHING-IN DIMENSIONS
■ To assure proper positioning in relation to wall, note
roughing-in dimensions.
Phillips Screwdriver
Plumbers' Putty or Caulking
-^1-5/8" TO 3-1/4"
Adjustable Wrench
Certified to comply with ANSI A112.18.1
Mg68952
Channel Locks
74"FOR
HEAD CLEARANCE
TUB RIM \ ,,
TOP OF^
- BOTTOM OF
TUB
OPTIONAL TO
FINISHED FLOOR
USUALLY BETWEEN
80" AND SB'
1/2" NPT
1-1/2" REF.
"SEE ILLUSTRATION"
INLETS
1/2" NPT
OUTLETS 1/2" NPT
THREADED INLETS (STOPS)
Page 2
INSTALL DIVERTER
When finished tiling the wall, remove PLASTER GUARD (1). Remove two screws that secure the DIVERTER LID [2) and remove Lid. Inspect the inside surface of diverter port. Diverter port must be free of any dirt. Clean if necessary.
Install DIVERTER (3) with SCREWS (4) removed with
DIVERTER LID (2). Operate DIVERTER (3). DIVERTER (3) should slide in
and out smoothly.
INSTALL VALVE TRIM
DIVERTER
PORT
Figure 1. Push CAP (1J over VALVE CARTRIDGE (2) until
seated against stop. Push CAP (3) over DIVERTER (4) until seated against stop.
Figure 2. Push ESCUTCHEON HOLDER (5) onto CAP(1J
and attach with SCREWS [S). Mount ESCUTCHEON SUPPORT (7) to ESCUTCHEON HOLDER (5) with SCREWS (8).
Figure 3. Align PINS (10) on back side of ESCUTCHEON (11)
with the FOUR HOLES (12) in ESCUTCHEON SUPPORT (7) and press ESCUTCHEON (11) flush against finished wall.
Figure 2.
M968952
Page 3
ADJUST HOT LIMIT STOP
HOT LIMIT SAFETY STOP ADJUSTMENT
By restricting handle rotation and limiting the amount of hot water allowed to mix with the cold, the HOT LIMIT SAFETY STOP reduces risk of accidental scalding. To set the maximum hot water temperature of your faucets, all you need to do is adjust the setting on the HOT LIMIT SAFETY STOP
■ Use a flat blade screwdriver or your fingers to pull
up and rotate red HOT LIMIT SAFETY STOP И).
Follow Step "A" or "B" to adjust min./max. discharge
temperature. "0" being the hottest to "7" the coldest temperature setting. Factory set at "0".
INSTALL DIVERTER KNOB, TUB SPOUT, SHOWER HEAD, SHOWER ARM WITH FLANGE
D
Thread DIVERTER KNOB (1) onto DIVERTER STEM [2].
Remove pipe cap and plug from shower and tub rough piping.
Install SPOUT ESCLfTCHEON (3) onto TUB SPOLfT (5).
Apply sealant or Teflon tape to threads of tub filler
nipple. Thread TUB SPOUT (5) onto tub nipple.
CAUTION: Protect finish on TUB SPOUT when insteiiing.
Install SHOWER ESCUTCHEON (S) onto SHOWER
ARM (7). Apply sealant or Teflon tape to threads on
both ends of SHOWER ARM I7J and thread longer leg of SHOWER ARM (7) into shower elbow.
Thread SHOWER HEAD (8) onto SHOWER ARM (7J.
CAUTION: Protect finish on SHOWER HEAD and ARM when instaiiing.
PLUG
TUB FILLER NIPPLE
M968952
Page 4
HANDLE INSTALLATION, INSTALL HANDLE ADAPTER
5a
INSTALL ADAPTER SCREW
Push HANDLE ADAPTER (1J onto VALVE STEM (2). Tighten set screw (3) with 2.5mm hex wrench supplied.
2.5MM HEX WRENCH
5b
INSTALL ADPATER
With a flat blade screwdriver thread ADAPTER (5) onto SET SCREW (4) and tighten.
With a flat blade screwdriver thread ADAPTER SCREW (4) into HANDLE STEM ADAPTER (2) and tighten.
5c
INSTALL HANDLE
Align HANDLE [6) and install onto HANDLE ADAPTER ASSEMBLY (7J. Tighten set screw (8) with 2.5mm hex wrench supplied to secure HANDLE.
Push PLUG BUTTDN (S) into set screw access hole in HANDLE (6).
Z.SMM HEX WRENCH
SERVICE
If faucet drips, operate handle several times
from "off" to "on". Do not apply excessive force.
Clogged CARTRIDGE (4) inlets may cause reduced flow in "full on" hot or cold. To clean inlets, first turn off water supply, then:
■ Remove HANDLE (1J, CAP (2) and CARTRIDGE (4).
■ Clean inlets and MANIFDLD (5).
Reassemble CARTRIDGE (4J, alternately tightening
SCREWS (3). Replace CAP (2) and HANDLE (1). Check flow.
EverClean™ Finish Care Instructions
American Standard’s EverClean finish will wipe clean with a soft, dry cloth. A soft cloth with clean water may also be used, if desired. IMo additional cleaning products are required.
DO NOT USE: Soaps, acid, polish, abrasives, harsh cleaners, or a cloth with a coarse surface. M968952
Page 5
Аш^1сам Shmùmi

MOMENTS

BATH/SHOWER TRIM KIT
WITH DIVERTER
MODEL NUMBER
T506.60X
M96E493-YYY0A
SHOWER ARM & FLANGE
M953540-YYY0A
SHOWER HEAD
Replace the "YYY" with appropriate finish code
CHROME STAINLESS STEEL □75
□Q2
M9B2557-YYY0A
SPOUT KIT
A910070-YYY0A
DIVERTER KNOB
910209-YYYOA
STREAM STRAIGHTENER
© American Standard Inc. 2007
Product names listed herein are trademarks of American Standard Inc.
For tolFfree information and answers to your questions, call:
IN CANADA 1-800387-0369 (TORONTO 1-905-306-1093]
HOT LINE FOR HELP
1 (BOO] 442-1902
Weekdays 8:00 a.m. to 6:00 p.m. EST
IN MEXICO 01-80CFB39-12-00
Weekdays 8:00 a.m. to 7:00 p.m. EST
M968952
Loading...