American Standard A112.19.9M, 9960.403, 9960.803, 9960.001 User Manual

MEZZO™ SEMI - COUNTERTOP SINK
19"
(482mm)
1-3/8" (35mm) Dia.
1 Hole for CHO
9960 001
1-3/8" (35mm) Dia. 3 Holes for 8" (203mm) centres 9960 803
1-1/4" (32mm) Dia. 3 Holes for 4" (102mm) centres 9960 403
2-3/4"
(70mm)
8"
(203mm)
22"
(559mm)
4"
(102mm)
8"
(203mm)
15"
(381mm)
21-1/2"
(546mm)
Countertop
10-1/2"
(267mm)
11"
(279mm)
13" min. (330mm)
10-1/2"
(267mm)
2-1/2"
(64mm)
10-1/2"
(267mm)
(cut out size)
Countertop By Others
Finished Floor
Finished Wall
8-1/4"
(210mm)
6"
(152mm)
34"
(864mm)
IN ONTARIO
33"
(838mm)
1-3/8"
(35mm)
4-3/8"
(111mm)
*
10-5/8"
(270mm)
*
12-7/8"
(327mm)
1-1/4 O.D.
WASTE
SUPPLY
SCREW NUT FLAT WASHER
#10 SCREW
MOUNTING BRACKET
COUNTERTOP -
BY OTHERS
WATERPROOF SEALANT
BASIN
• Space saving design installs on a minimum countertop depth of 13"
• Made from reclay china
• Rear overow
• Recessed self-draining deck
• Barrier-free design
• Self rimming with sealant
• Cutout template and mounting kit provided (Faucet shown not included)
9960.803 Faucet holes on 8" (203mm) centers
(illustrated)
9960.403 Faucet holes on 4" (102mm) centers ❏ 9960.001 Center hole only
Nominal Dimensions: 22" (559mm) wide, 21-1/2" (546mm) deep
Bowl sizes:
19" (482mm) wide 15" (381mm) front to back 6-7/8" (175mm) deep
Fixture Dimensions conform to ANSI Standard A112.19.9M
Compliance Certications ­Meets or Exceeds the Following Specications:
• ASME A112.19.9M for Non-Vitreous
• CAN/CSA B45 series
• A1995 National Building Code, section 3.7 and CAN/CSA-B651-02 and OBC 3.8
Ceramic Fixtures
MEZZO™
SEMI-COUNTERTOP SINK
FIRECLAY
To Be Specied:
Color: White Bone Linen Black Faucet*: Faucet Finish: Supplies & Stops: Trap 1-1/4" (32 mm):
* See faucet section for additional models available
NOTES:
*
ARE SUGGESTED. FOR COUNTERTOP CUTOUT AND INSTALLATION INSTRUCTIONS USE TEMPLATE SUPPLIED WITH SINK . FITTINGS NOT INCLUDED AND MUST BE ORDERED SEPARATELY. INSTALLATION INSTRUCTIONS SUPPLIED WITH LAVATORY.
IMPORTANT: Dimensions of xtures are nominal and may vary within the range of tolerances established by ANSI Standard A112.19.9M.
These measurements are subject to change or cancellation. No responsibility is assumed for use of superseded or voided pages.
© 2008 AS America Inc.
DIMENSIONS SHOWN FOR LOCATION OF SUPPLIES AND “P" TR AP
J28