ASSEMBLY & INSTALLATION
INSTRUCTIONS
Providence 32" Vanity with Wood Top
9432.200
VANITY TOP RECOMMENDED SINKS
WOOD TOP (SUPPLIED) SEBRING 0573
MARBLE TOP (OPTIONAL)
9432.495
Thank you for selecting our products...products which have been the benchmarks of fine quality for over 100 years.
To help insure that the installation process will proceed smoothly, please read these instructions carefully before you
begin. Also, review the recommended tools and materials list; carefully unpack and examine your new plumbing fixture.
To maintain the beauty of the finish, avoid placing the furniture in direct sunlight, as sunlight causes fading. Also avoid
extreme changes in temperature by arranging furniture away from radiators, heat and air vents, and air conditioning units.
Avoid placing furniture directly under windows.
COVENTRY 0575
TOWN SQUARE 0700
OVALYN 0495.221
Recommended Tools & Materials
Adjustable Wrench
Basin Wrench
Tubing Cutter
Channel Locks
Plumbers' Putty or
Caulking
Roughing-in Dimensions
32"
WASTE
813mm
6"
(152mm)
ANCHORING HOLES
5"
(127mm)5"TYP
1-1/4" O.D.
32-1/2"
826mm
A
FINISHED FLOOR
SUPPLIES
AS REQ'D
Hacksaw
10'
Tape
Saber Saw
Measure
A = 35"(889mm) for Wood top
A = 35-1/4"(895mm) for Marble top
24-3/4"
629mm
22-3/4"
578mm
DOOR SWING 180°
DEPTH WITH DOORS
1/2 OPEN = 33-1/2"
WIDTH WITH BOTH DOORS
FULL OPEN= 53"
Pipe Wrench
Putty Knife
Drill
Phillips Screwdriver
Regular Screwdriver
Level
21-1/2"
546mm
Product names listed herein are trademarks of American Standard Inc.
© American Standard Inc. 2005
730544-100 Rev. C
- 1 -
VANITY INSTALLATION
Provide suitable reinforcement required for anchoring the vanity to the wall. Centerline of reinforcement should be 321/2" up from the floor (see Figure 1).
Back legs are set inward from the rear of the vanity which allows the vanity to sit flush against the wall over most types of
molding. If the vanity interferes with the molding, the molding needs to be notched to seat the vanity flush against the
wall (see Figure 2).
Rough in supply lines and waste per rough in dimensions.
NOTE: If current supply lines are greater than 6" on center, they may interfere with cutout in rear of vanity or vanity shelf.
Remove the wood top from the vanity. The top is held in place from the underside by 4 screws, 1 through each of the 4
angled corner braces.
Move the vanity into place and level with the adjustable glides on the bottom of the feet. The glides can be adjusted
outward up to 1" but it is recommended not to exceed 1/2" if possible. Anchor it to the wall through at least 2 of the
anchoring holes in the rear of the vanity (see Figure 2).
21-1/2"
Continue with installation appropriate for top and sink options chosen.
C/L of 2 x 6
Reinforcement
FIGURE 1
32-1/2"
FIGURE 2
ADJUSTABLE GLIDES
(LOCATED UNDER
EACH FOOT)
Finished
Floor
546mm
ANCHORING
HOLES
32-1/2"
826mm
Wood Top with Recommended Sinks...
Two people recommended for this installation
Determine which sink is being installed and follow the instructions printed on the
appropriate template supplied with vanity.
NOTE: American Standard is not responsible for cut-out errors when the
incorrect cut-out template is used.
If Installing: Use Template:
Sebring 0573 730541-400
Coventry 0575 730542-400
Town Square 0700 730543-400
After top is replaced, connect the trap to the drain assembly hand tight to check
alignment. It may be necessary to cut off part of the tailpiece (area "A") or part
horizontal leg of the trap (area "B").
Connect hot and cold supply lines to the shut off valves. Tighten trap joints for
watertight assembly.
WOOD V ANITY T OP
IMPORTANT: BE SURE TO CENTER SINK
CUT OUT HORIZONTALLY ON VANITY TOP.
MOLDING
P APER TEMPLATE
B
A
- 2 -
730544-100 Rev. C