American Standard 9210.224.329 User Manual

ASSEMBLY & INSTALLATION INSTRUCTIONS
- 1 -
Recommended Tools & Materials
Roughing-in Dimensions
Product names listed herein are trademarks of American Standard Inc. © American Standard Inc. 2008
Hacksaw
Channel Locks
Adjustable Wrench
Tubing Cutter
Basin Wrench
Putty Knife
Tape Measure
Plumbers’ Putty or Caulking
Regular Screwdriver
Phillips Screwdriver
Drill
Level
Pipe Wrench
Generations 24" Washstand
9210.224.329
770 0 0 2-1 0 0 770 0 0 2-1 0 0 770 0 0 2-1 0 0 770 0 0 2-1 0 0
Thank you for selecting our products...products which have been the benchmarks of fine quality for over 100 years. To help insure that the installation process will proceed smoothly, please read these instructions carefully before you begin. Also, review the recommended tools and materials list; carefully unpack and examine your new plumbing fixture.
To maintain the beauty of the finish, avoid placing the furniture in direct sunlight, as sunlight causes fading. Also avoid extreme changes in temperature by arranging furniture away from radiators, heat and air vents, and air conditioning units. Avoid placing furniture directly under windows.
22-1/2"
(570mm)
18"
(457mm)
33"
(838mm)
14-1/8"
(359mm)
16"
(406mm)
18"
(457mm)
TOWNSEND
SINK
SUPPLIES AS
REQUIRED
FINISHED
FLOOR
FINISHED
FLOOR
FINISHED
WALL
VANITY TOP
No top required for Townsend Vanity Top (sink)
0555.104 Townsend Vanity Top (4" centers)
0555.108 Townsend Vanity Top (8" centers)
7005.201 Copeland Center Spread
7005.801 Copeland Wide Spread
RECOMMENDED SINKS RECOMMENDED FAUCETS
1-1/4" O.D.
WASTE
8"
(203mm)
- 2 -
WASHSTAND INSTALLATION
Unpack unit carefully, taking care that bottom shelf does not drop and damage front legs (see Figure 2).
Provide suitable reinforcement for anchoring the washstand to the wall. Centerline of reinforcement should be 27-3/4" up from the floor (see Figure 1).
Rough in supply lines and waste per rough-in dimensions.
The molding needs to be notched to seat the washstand flush against the wall.
Move the washstand into place and level with the adjustable glides on the bottom of the feet. The glides can be adjusted outward up to 1" but it is recommended not to exceed 1/2" if possible.
Drill at least two 3/8" O.D. anchoring holes through the centerline of the rear stringer of the vessel stand, located 3/4" down from the top of the table (see Figure 2).
Anchor the washstand to the wall through at least 2 of the anchoring holes in the rear of the washstand (see Figure 2).
Continue with installation appropriate for top and sink options chosen.
C/L of 2 x 6 Reinforcement
Finished Floor
27-3/4"
(705mm)
FIGURE 1
ADJUSTABLE
LEVELLERS
(under each foot)
FINISHED
FLOOR
FINISHED
WALL
REAR STRINGER
WITH ANCHORING
HOLES TO SECURE
VANITY TO WALL
FIGURE 2
ANCHORING HOLES IN REAR STRINGER [NOT SHOWN]
33"
(838mm)
2-1/2"
(64mm)
4"
(102mm)
Loading...
+ 2 hidden pages