American Standard 9205.024.339 User Manual

ASSEMBLY & INSTALLATION INSTRUCTIONS
Studio 22" RTU Vanity
9205.024.339
VANITY TOP
9205.124 Laminated 22" Marble Top
0978.000.321 Frosted Glass Round Vessel
RECOMMENDED SINKS RECOMMENDED FAUCETS
0978.000.200 Clear Glass Round Vessel
No top required for Rectangular
0960.000.020 China Round Vessel
0621.001.020 Rectangular Vessel Sink
2506.101 Moments Faucet
Vessel Sink
Thank you for selecting our products...products which have been the benchmarks of fine quality for over 100 years. To help insure that the installation process will proceed smoothly, please read these instructions carefully before you begin. Also, review the recommended tools and materials list; carefully unpack and examine your new plumbing fixture.
To maintain the beauty of the finish, avoid placing the furniture in direct sunlight, as sunlight causes fading. Also avoid extreme changes in temperature by arranging furniture away from radiators, heat and air vents, and air conditioning units. Avoid placing furniture directly under windows.
Recommended Tools & Materials
Adjustable Wrench
Basin Wrench
Tubing Cutter
Plumbers’ Putty or Caulking
Hacksaw
Tape Measure
Pipe Wrench
Putty Knife
Drill
Phillips Screwdriver
Regular Screwdriver
Level
Roughing-in Dimensions
Product names listed herein are trademarks of AS America, Inc. © AS America, Inc. 2008
SQUARE
CHINA
30-1/4"
(768mm)
SINK
6-3/8"
(162mm)
21-3/4"
(552mm)
8"
(203mm)
1-1/4"(32mm) O.D. WASTE
FINISHED
FLOOR
- 1 -
OPTIONAL:
LAMINATED MARBLE TOP WITH VESSEL
18"
(456mm)
16"
(406mm)
18-3/16"
(462mm)
FINISHED
FLOOR
REAR STRINGER WITH ANCHORING HOLES TO SECURE VANITY TO WALL
3-7/8"
(98mm)
FINISHED
WALL
770015-100
RTU (Ready to Unfold) VANITY INSTALLATION
Unpack unit carefully, taking care that bottom shelf does not drop and damage front legs (see Figure 2).
Provide suitable reinforcement for anchoring the vanity to the wall. Centerline of reinforcement should be 28-1/2" up from the floor (see Figure 1).
Rough in supply lines and waste per rough-in dimensions.
Unfold the vanity and position in desired location. The molding needs to be notched to seat the vanity flush against the wall.
Move the vanity into place and level with the adjustable glides on the bottom of the feet. The glides can be adjusted outward up to 1" but it is recommended not to exceed 1/2" if possible.
Drill at least two 3/8" O.D. anchoring holes through the centerline of the rear stringer of the vessel stand, located 3/4" down from the top of the table (see Figure 2).
Anchor the vanity to the wall through at least 2 of the anchoring holes in the rear of the vanity (see Figure 2).
Continue with installation appropriate for top and sink options chosen.
FIGURE 1
C/L of 2 x 6 Reinforcement
FIGURE 2
28-1/2"
(724mm)
Finished Floor
ANCHORING
HOLES IN REAR
STRINGER
(NOT SHOWN)
- 2 -
ADJUSTABLE
LEVELLERS
(under each foot)
770015-100
Loading...
+ 2 hidden pages