American Standard 7A0018A100A, 7A0024A100A, 7A0030A100A, 7A0036A100A, 7A0042A100A Product Data

...
SPLIT SYSTEM COOLING
MODELS 7A0018-060
© American Standard Inc. 1999
ALLEGIANCE® 10
PUB. NO . 12-1112-03
Tab 1 — December 1999
PRODUCT DA TA
American Standard Inc., Tyler, TX 75711-9010
Features and Benefits
Split System Cooling Units . . . Designed With Your Needs In Mind.
®
Allegiance a new approach to designing products for American-Standard. The design team’s mission is “.. . to br ing a system to the marketplace that will meet your job requirements ever y time” .. . And at a competitive price.
High efficiency Duration™ compressor
Attractive warm gray color
Brazed refrigerant connections
Multi-use service valves
Sculpted, contoured top
Recessed fan grille
Screw covers on fan grille
Steel cabinet, full coil protection
Powder paint covers uniformly to resist r ust & corrosion
Fast draining base pan assembly
Liquid line filter-drier
Single side ser vice access
7A0 cor ner shipping blocks used for base spacers
Cavities in base pan designed for standard
heat pump legs
10 split systems represent
American-Standard’s experienced design team used the newest computer technology and an entirely new manufacturing process to develop a new standard in split systems. Couple the American-Standard reputation for quality and reliability in split system air conditioners with improvements in efficiency, flexibility and installation ease . . . and you have systems that are “Built To A Higher Standard.”
Vertical air discharge
Direct drive propeller fan
Factory supplied charge of HCFC
Weatherproof electrical controls
Low ambient cooling to 55°F. as shipped
Low ambient cooling to 40°F. with EDC accessory
AY28X079
Low ambient cooling to 30°F. with EDC accessory AY28X079 and TXV
5-year limited warranty on compressor & coil, 1-year on parts
Optional extended warranties
A.R.I. STANDARD CAPACITY RATING CONDITIONS
A.R.I. STANDARD 210 RATING CONDITIONS — (A) Cooling 80°F. D.B., 67°F. W.B. air entering indoor coil, 95°F. D.B. air
entering outdoor coil. A.R.I. STANDARD 270 RATING CONDITIONS — (Noise rating numbers are determined with the unit in cooling operation.)
Standard Noise Rating number is at 95°F. outdoor air.
2
DATA SUBJECT TO CHANGE WITHOUT NOTICE
Contents
PRODUCT DA TA
American Standard Inc., Tyler, TX 75711-9010
Manufacturing Control
American-Standard’s exclusive control over the design and manufacturing of all major components is unique in the industry. This approach assures us total control over both the quality and reliability of these components. It also allows us to custom match components to deliver the best in split system performance.
Designing the Details
Careful attention was given to designing the details — from control wiring to the access panels. These units feature time­saving color-coded wiring and removable panels which allow complete access to all major components and controls. All outdoor units feature external high and low pressure gauge port connections. Service valves for easy diagnosing and servicing of the unit are provided.
Standardized Cabinets
In addition all cabinets have been standardized; so when you are ser vicing an outdoor unit or an air handler all components are in the same location from unit to unit.
UL Listed
American-Standard meets or exceeds all nationally recognized agency safety and design standards. Each condensing unit is designed, approved, and labeled in accordance to UL Standards: UL 1995 for central cooling air conditioners and for refrigeration and air conditioning condensing and compressor units, including approval for use in Canada. Each unit is rated in accordance with ARI Standard 210 and 270.
Features and Benefits 2
Model Number Description 4
Optional Equipment 4
General Data
7A0018A100A 5 7A0024A100A 7 7A0030A100A 9 7A0036A100A 12 7A0042A100A 14 7A0048B100A 16
7A0060B100A 18
Ratings with
Auxiliary Devices 20
T ypical Wiring 24
Dimensional Data 26
DATA SUBJECT TO CHANGE WITHOUT NOTICE
Mechanical Specifications 27
DATA SUBJECT
TO CHANGE
WITHOUT NOTICE
3
PRODUCT DA TA
American Standard Inc., Tyler, TX 75711-9010
1234*56789101112
7A0042A100A0
Model Number Description
Outdoor Product Type Split Cooling - 7A, 7B, 7C
Split Heat Pump - 6H, 6C
Efficiency 0 - 10 SEER
1 - 11 SEER 2 - 12 SEER 4 - 14 SEER
Primary Capacity Example: 042 = 42 MBTUH = 4 Tons
Secondary Functions
Voltage/Power Supply 1 - 200-230 Volts 1 Phase
3 - 208-230 Volts 3 Phase 4 - 460 Volts 3 Phase
Major Design Modification
Product/Service/Parts
Minor Design Modifications
OPTIONAL EQUIPMENT
OPTIONAL EQUIPMENT FOR CONDENSING UNITS (Check mark [
Indoor Thermostats — Prog. Electronic Setback 3 Heating/2 Cooling...................................................................................ASYSTAT620 [ ]
Outdoor Thermostat ............................................................................................................................................................... TAYSTAT250A [ ]
Evaporator Defrost Control .......................................................................................................................................................... AY28X079 [ ]
Indoor Fan Delay Relay Kit ........................................................................................................................................................ BAY24X045 [ ]
Humidistat.................................................................................................................................................................................ASYSTAT625 [ ]
5 Minute Delay Relay1 ......................................................................................................................................................... TAYASCT501A [ ]
Quick Start Kit (7A0018,024,036,042A) .............................................................................................................................. BAYKSKT250A [ ]
Quick Start Kit (7A0048-60B) .............................................................................................................................................. BAYKSKT252A [ ]
Rubber Isolators ........................................................................................................................................................................ BAYISLT100 [ ]
Crankcase Heater Kit (7A0048B)2 ..................................................................................................................................... BAYCCHT200A [ ]
Crankcase Heater Kit (7A0060B)2 ..................................................................................................................................... BAYCCHT201A [ ]
1
Do not use with programmable thermostats.
2
When field inner connecting lines exceed 60 linear ft. of length consult refrigerant piping software (Pub. No. 12-3312-01).
Prog. Electronic Setback 1 Heating/1 Cooling................................................................................... ASYSTAT621 [ ]
Cooling Only with Fan Switch ............................................................................................................ ASYSTAT603 [ ]
Heating/Cooling — Vertical ................................................................................................................ ASYSTAT604 [ ]
Heating/Cooling — Horizontal............................................................................................................ ASYSTAT605 [ ]
Manual 2 Heating/1 Cooling...............................................................................................................ASYSTAT606 [ ]
Thermostat Locking Cover................................................................................................................... BAY28X190 [ ]
✓✓
] indicates accessories included).
✓✓
BRAZED TUBING REFRIGERANT LINE SETS (All Suction Lines are Insulated.)
5/8" ODM (90° bend, one end), 5/8" & 1/4" tubing ............................................................................................................. TAYREFLN1__* [ ]
3/4" ODM (90° bend, one end), 3/4" & 5/16" tubing ........................................................................................................... TAYREFLN2__* [ ]
7/8" ODM (90° bend, one end), 7/8" & 3/8" tubing ............................................................................................................. TAYREFLN3__* [ ]
1-1/8" ODM (90° bend, one end), 1-1/8" & 3/8" tubing....................................................................................................... TAYREFLN4__ * [ ]
*Line lengths: 15, 20, 25, 30, 40 & 50 ft. Insert desired line length in catalog number at right for the complete number. Example: TAYREFLN220.
LOW OUTDOOR AMBIENT COOLING
Low Ambient As Evaporator Cooling Manufactured Defrost Control
FCCV Accutron 55°F 40°F Thermal Expansion Valve (TXV) 45°F 30°F
4
DATA SUBJECT TO CHANGE WITHOUT NOTICE
American Standard Inc., Tyler, TX 75711-9010
General Data — 7A0018A100A
PRODUCT DA TA
OUTDOOR UNIT
POWER CONNS. — V/PH/HZ MIN. BRCH. CIR. AMP A CITY 11 BR. CIR. MAX. (AMPS) 15 PROT. RTG.
NOISE RATING (DECIBELS) COMPRESSOR DURATION™
NO. USED - NO. SPEEDS 1 - 1 VOL TS/PH/HZ 200/230/1/60 R.L. AMPS F ACT ORY INST ALLED
START COMPONENTS INSULA TION/SOUND BLANKET NO COMPRESSOR HEAT NO
OUTDOOR F AN — TYPE PROPELLER DIA. (IN.) - NO. USED 18 - 1 TYPE DRIVE - NO. SPEEDS DIRECT - 1 CFM @ 0.0 IN. W.G. NO. MOTORS - HP 1 - 1/8 MOT OR SPEED R.P.M. 1075 VOL TS/PH/HZ 200/230/1/60 F.L. AMPS 0.75
OUTDOOR COIL — TYPE SPINE FIN™ ROWS - F.P.I. 1 - 24 F ACE AREA (SQ. FT.) 10.61 TUBE SIZE (IN.) 3/8
REFRIGERANT LBS. — R-22 (O.D. UNIT) FA CT ORY SUPPLIED YES LINE SIZE - IN. O.D. GAS LINE SIZE - IN. O .D. LIQ.
FCCV RESTRICTOR ORIFICE SIZE 0.049
DIMENSIONS H X W X D OUTDOOR UNIT - CRATED (IN.) 27-3/8 X 31-1/2 X 27-5/8 UNCRATED SEE OUTLINE DWG.
WEIGHT SHIPPING (LBS.) 166 NET (LBS.) 148
12
3
}
MIN. (AMPS) 15
2
7
- L.R. AMPS 8.0 - 45
8
4
5
6
6
7A0018A100A
200/230/1/60
3-LBS., 13-OZ.
80
NO
1960
5/8 1/4
1
CERTIFIED IN ACCORD ANCE WITH THE UNITARY AIR-CONDITIONER EQUIPMENT CERTIFICATION PROGRAM, WHICH IS BASED ON A.R.I. ST AND ARD 210/240.
2
RA TED IN A CCORD ANCE WITH A.R.I. STANDARD 270.
SPLIT SYSTEM
3
CALCULATED IN ACCORDANCE WITH NATL. ELECTRIC CODE. ONLY USE HACR CIRCUIT BREAKERS OR FUSES.
4
STANDARD AIR - DRY COIL - OUTDOOR
5
THIS VALUE APPROXIMATE. FOR MORE PRECISE V ALUE SEE UNIT NAMEPLATE AND SERVICE INSTR UCTION.
6
MAX. LINEAR LENGTH: 80 FT WITH RECIPROCA TING COMPRESSOR ­60 FT WITH SCROLL. MAX. LIFT - SUCTION 60 FT; MAX LIFT - LIQUID 60 FT. FOR GREATER LENGTH REFER TO REFRIGERANT PIPING SOFTWARE PUB. NO . 12-3312-01.
7
THE VALUE SHOWN FOR COMPRESSOR RLA ON THE UNIT NAMEPLATE AND ON THIS SPECIFICATION SHEET IS USED TO COMPUTE MINIMUM BRANCH CIRCUIT AMPACITY AND MAXIMUM FUSE SIZE. THE V ALUE SHOWN IS THE BRANCH CIRCUIT SELECTION CURRENT.
8
NO MEANS NO START COMPONENTS. YES MEANS QUICK START KIT COMPONENTS. PTC MEANS POSITIVE TEMPERATURE COEFFICIENT STARTER.
CONDENSING UNIT WITH COOLING COILS
CCBA18A4ACC CCBA24A4ACC CUBA18A4ACC CUBA24A4ACC TXA018C4 TXA024C4 TXA025C4
EXPANSION TYPE FIXED ORIFICE FIXED ORIFICE FIXED ORIFICE FIXED ORIFICE FA CT INS 49 CHG T O 49 CHG T O 49 RA TINGS (COOLING)
BTUH (TO TAL) 17200 17100 17200 17100 17200 17300 17600 BTUH (SENSIBLE) 11400 11800 11400 11800 11400 11900 12800 INDOOR AIRFLOW (CFM) 600 640 600 640 600 645 660 SYSTEM POWER (KW) 1.74 1.68 1.74 1.68 1.74 1.74 1.75
SEER (BTU/WATT-HR.) 10.00 10.50 10.00 10.50 10.00 10.15 10.20
EXPANSION TYPE FA CT INS 49 CHG TO 49 CHG TO 49 CHG TO 49 CHG TO 49 CHG TO 49 RA TINGS (COOLING)
BTUH (TO TAL) 17200 17300 17300 17600 17600 17900 BTUH (SENSIBLE) 11400 11900 11900 12800 12800 12400 INDOOR AIRFLOW (CFM) 600 645 645 660 660 670 SYSTEM POWER (KW) 1.73 1.74 1.74 1.75 1.75 1.79
SEER (BTU/WATT-HR.) 10.00 10.15 10.15 10.20 10.20 10.50
1
TXC018C4 TXC024C4 TXC024D4 TXC025C4 TXC025D4 TXH025A4
1
CONDENSING UNIT WITH AIR HANDLERS
TVF018A14 TVF024A14 TVF025A14 TWE018C14 TWE024C14 TWG018A14 TWG025A14
EXPANSION TYPE FA CT INS 49 CHG TO 49 CHG T O 49 FACT INS 49 CHG TO 49 FACT INS 49 CHG TO 49 RA TINGS (COOLING)
BTUH (TO TAL) 17800 17900 18000 17000 16800 17000 16600 BTUH (SENSIBLE) 12800 13400 13500 11400 11700 11600 11900 INDOOR AIRFLOW (CFM) 600 670 675 600 630 600 620 SYSTEM POWER (KW) 1.71 1.79 1.76 1.63 1.72 1.70 1.61
SEER (BTU/WATT-HR.) 10.80 10.35 10.60 10.85 10.10 10.75 10.20
See page 20 for combinations with Auxiliary Devices .
1
DATA SUBJECT TO CHANGE WITHOUT NOTICE
5
PRODUCT DA TA
American Standard Inc., Tyler, TX 75711-9010
CONDENSING UNIT WITH AIR HANDLERS
TWG030A14
EXP ANSION TYPE CHG TO 49 RA TINGS (COOLING)
BTUH (TO TAL) 18100 BTUH (SENSIBLE) 13000 INDOOR AIRFLOW (CFM) 675 SYSTEM POWER (KW) 1.80
SEER (BTU/WATT-HR.) 10.75
EXP ANSION TYPE TXV-B RA TINGS (COOLING)
BTUH (TO TAL) 18800 BTUH (SENSIBLE) 13300 INDOOR AIRFLOW (CFM) 575 SYSTEM POWER (KW) 1.59
SEER (BTU/WATT-HR.) 10.90
See page 20 for combinations with Auxiliary Devices.
1
CONDENSING UNIT WITH FURNA CES & COILS
AUY080R9V3
+TXC031E5
1
General Data — 7A0018A100A
6
DATA SUBJECT TO CHANGE WITHOUT NOTICE
American Standard Inc., Tyler, TX 75711-9010
General Data — 7A0024A100A
PRODUCT DA TA
OUTDOOR UNIT
POWER CONNS. — V/PH/HZ MIN. BRCH. CIR. AMP A CITY 15 BR. CIR. MAX. (AMPS) 25 PROT. RTG.
NOISE RATING (DECIBELS) COMPRESSOR DURATION™
NO. USED - NO. SPEEDS 1 - 1 VOL TS/PH/HZ 200/230/1/60 R.L. AMPS F ACT ORY INST ALLED
START COMPONENTS INSULA TION/SOUND BLANKET NO COMPRESSOR HEAT NO
OUTDOOR F AN — TYPE PROPELLER DIA. (IN.) - NO. USED 18 - 1 TYPE DRIVE - NO. SPEEDS DIRECT - 1 CFM @ 0.0 IN. W.G. NO. MOTORS - HP 1 - 1/8 MOT OR SPEED R.P.M. 1075 VOL TS/PH/HZ 200/230/1/60 F.L. AMPS 0.75
OUTDOOR COIL — TYPE SPINE FIN™ ROWS - F.P.I. 1 - 24 F ACE AREA (SQ. FT.) 10.61 TUBE SIZE (IN.) 3/8
REFRIGERANT LBS. — R-22 (O.D. UNIT) FA CT ORY SUPPLIED YES LINE SIZE - IN. O.D. GAS LINE SIZE - IN. O .D. LIQ.
FCCV RESTRICTOR ORIFICE SIZE 0.057
DIMENSIONS H X W X D OUTDOOR UNIT - CRATED (IN.) 27-3/8 X 31-1/2 X 27-5/8 UNCRATED SEE OUTLINE DWG.
WEIGHT SHIPPING (LBS.) 173 NET (LBS.) 155
12
3
}
MIN. (AMPS) 20
2
7
- L.R. AMPS 11.6 - 67
8
4
5
6
6
7A0024A100A
200/230/1/60
4-LBS.,3-OZ.
80
NO
1960
3/4
5/16
1
CERTIFIED IN ACCORD ANCE WITH THE UNITARY AIR-CONDITIONER EQUIPMENT CERTIFICATION PROGRAM, WHICH IS BASED ON A.R.I. ST AND ARD 210/240.
2
RA TED IN A CCORD ANCE WITH A.R.I. STANDARD 270.
SPLIT SYSTEM
3
CALCULATED IN ACCORDANCE WITH NATL. ELECTRIC CODE. ONLY USE HACR CIRCUIT BREAKERS OR FUSES.
4
STANDARD AIR - DRY COIL - OUTDOOR
5
THIS VALUE APPROXIMATE. FOR MORE PRECISE V ALUE SEE UNIT NAMEPLATE AND SERVICE INSTR UCTION.
6
MAX. LINEAR LENGTH: 80 FT WITH RECIPROCA TING COMPRESSOR ­60 FT WITH SCROLL. MAX. LIFT - SUCTION 60 FT; MAX LIFT - LIQUID 60 FT. FOR GREATER LENGTH REFER TO REFRIGERANT PIPING SOFTWARE PUB. NO . 12-3312-01.
7
THE VALUE SHOWN FOR COMPRESSOR RLA ON THE UNIT NAMEPLATE AND ON THIS SPECIFICATION SHEET IS USED TO COMPUTE MINIMUM BRANCH CIRCUIT AMPACITY AND MAXIMUM FUSE SIZE. THE V ALUE SHOWN IS THE BRANCH CIRCUIT SELECTION CURRENT.
8
NO MEANS NO START COMPONENTS. YES MEANS QUICK START KIT COMPONENTS. PTC MEANS POSITIVE TEMPERATURE COEFFICIENT STARTER.
CONDENSING UNIT WITH COOLING COILS
CCBA24A4ACC CCBA30A4ACC CCBB30A4ACC CUBA24A4ACC CUBA30A4ACC CUBB30A4ACC TXA018C4
EXPANSION TYPE FIXED ORIFICE FIXED ORIFICE FIXED ORIFICE FIXED ORIFICE FIXED ORIFICE FIXED ORIFICE CHG T O 57 RA TINGS (COOLING)
BTUH (TO TAL) 22400 21800 22400 22400 21800 22400 21200 BTUH (SENSIBLE) 14700 14700 16400 14700 14700 16400 13400 INDOOR AIRFLOW (CFM) 800 815 840 800 815 840 675 SYSTEM POWER (KW) 2.40 2.37 2.40 2.40 2.37 2.40 2.28
SEER (BTU/WATT-HR.) 10.00 10.00 10.05 10.00 10.00 10.05 10.00
EXPANSION TYPE FA CT INS 57 F ACT INS 57 CHG TO 57 CHG TO 57 CHG TO 57 CHG TO 57 CHG TO 57 RA TINGS (COOLING)
BTUH (TO TAL) 23000 22600 23200 23400 23200 23800 23800 BTUH (SENSIBLE) 15100 15500 15900 16900 15900 17300 17300 INDOOR AIRFLOW (CFM) 800 800 870 875 870 890 890 SYSTEM POWER (KW) 2.45 2.39 2.46 2.46 2.46 2.48 2.48
SEER (BTU/WATT-HR.) 10.00 10.05 10.05 10.05 10.05 10.10 10.10
7A0024A WITH TXC018C4 TXC024C4 TXC024D4 TXC025C4 TXC025D4 TXC030C4 TXC030D4 EXPANSION TYPE CHG TO 57 FACT INS 57 FACT INS 57 FA CT INS 57 F A CT INS 57 CHG T O 57 CHG TO 57 RA TINGS (COOLING)
BTUH (TO TAL) 21200 23000 23000 22600 22600 23200 23200 BTUH (SENSIBLE) 13400 15100 15100 15500 15500 15900 15900 INDOOR AIRFLOW (CFM) 675 800 800 800 800 870 870 SYSTEM POWER (KW) 2.28 2.45 2.45 2.39 2.39 2.46 2.46
SEER (BTU/WATT-HR.) 10.00 10.00 10.00 10.05 10.05 10.05 10.05
See page 20 for combinations with Auxiliary Devices .
1
TXA024C4 TXA025C4 TXA030C4 TXA031C4 TXA035C4 TXA036C4 TXA037C4
1
1
DATA SUBJECT TO CHANGE WITHOUT NOTICE
7
PRODUCT DA TA
American Standard Inc., Tyler, TX 75711-9010
General Data — 7A0024A100A
CONDENSING UNIT WITH COOLING COILS
TXC031C4 TXC031D4 TXC031E5 TXC035C4 TXC035D4 TXC036C4 TXC036D4
EXP ANSION TYPE CHG TO 57 CHG TO 57 TXV -B CHG TO 57 CHG TO 57 CHG TO 57 CHG TO 57 RA TINGS (COOLING)
BTUH (TO TAL) 23400 23400 23800 23200 23200 23800 23800 BTUH (SENSIBLE) 16900 16900 17400 15900 15900 17300 17300 INDOOR AIRFLOW (CFM) 875 875 890 870 870 890 890 SYSTEM POWER (KW) 2.46 2.46 2.45 2.46 2.46 2.48 2.48
SEER (BTU/WATT-HR.) 10.05 10.0 5 10.35 10.05 10.05 10.10 10.10
EXP ANSION TYPE TXV-B CHG T O 57 TXV-B F ACT INS 57 F A CT INS 57 RA TINGS (COOLING)
BTUH (TO TAL) 24200 23800 24200 23200 24400 BTUH (SENSIBLE) 17800 17300 17800 15300 17500 INDOOR AIRFLOW (CFM) 900 890 900 800 900 SYSTEM POWER (KW) 2.46 2.48 2.46 2.47 2.55
SEER (BTU/WATT-HR.) 10.50 10.1 0 10.50 10.10 10.15
1
TXC036E5 TXC037C4 TXC037E5 TXH025A4 TXH033A4
1
CONDENSING UNIT WITH AIR HANDLERS
TVF018A14 TVF024A14 TVF025A14 TVF030A14 TVF036A14 TWE018C14 TWE024C14
EXP ANSION TYPE CHG TO 57 CHG TO 57 CHG TO 57 CHG TO 57 CHG TO 57 CHG TO 57 CHG TO 57 RA TINGS (COOLING)
BTUH (TO TAL) 22400 23200 23200 24000 24200 22400 22600 BTUH (SENSIBLE) 15000 16400 16400 18000 18200 14300 15000 INDOOR AIRFLOW (CFM) 675 800 800 900 900 675 800 SYSTEM POWER (KW) 2.36 2.44 2.40 2.47 2.56 2.38 2.42
SEER (BTU/WATT-HR.) 10.30 10.3 0 10.50 10.50 10.15 10.15 10.10
EXP ANSION TYPE CHG TO 57 CHG TO 57 CHG TO 57 CHG TO 57 CHG TO 57 RA TINGS (COOLING)
BTUH (TO TAL) 23000 23600 21800 22400 22800 BTUH (SENSIBLE) 16400 16900 14200 15200 15900 INDOOR AIRFLOW (CFM) 860 885 675 800 855 SYSTEM POWER (KW) 2.45 2.50 2.34 2.33 2.44
SEER (BTU/WATT-HR.) 10.20 10.2 0 10.15 10.00 10.00
1
TWE030C14 TWE036C14 TWG018A14 TWG025A14 TWG030A14
1
CONDENSING UNIT WITH FURNA CES & COILS
ADD080R9V3 ADD080R9V3 ADD100R9V5 AUD080R9V3 AUD080R9V3 AUD100R9V5 AUY080R9V3
+TXC031E5 +TXC036E5 +TXC037E5 +TXC031E5 +TXC036E5 +TXC037E5 +TXC031E5
EXP ANSION TYPE TXV-B TXV -B TXV-B TXV-B TXV-B TXV-B TXV-B RA TINGS (COOLING)
BTUH (TO TAL) 23800 24400 24400 23800 24400 24400 24600 BTUH (SENSIBLE) 16600 17300 17400 16800 17500 17400 17400 INDOOR AIRFLOW (CFM) 775 775 800 800 825 800 800 SYSTEM POWER (KW) 2.22 2.24 2.22 2.26 2.26 2.22 2.32
SEER (BTU/WATT-HR.) 10.70 10.8 0 10.80 10.70 10.80 10.80 10.90
EXP ANSION TYPE TXV-B RA TINGS (COOLING)
BTUH (TO TAL) 25200 BTUH (SENSIBLE) 18000 INDOOR AIRFLOW (CFM) 800 SYSTEM POWER (KW) 2.33
SEER (BTU/WATT-HR.) 10.90
See page 20 for combinations with Auxiliary Devices.
1
AUY080R9V3
+TXC036E5
1
8
DATA SUBJECT TO CHANGE WITHOUT NOTICE
American Standard Inc., Tyler, TX 75711-9010
General Data — 7A0030A100A
PRODUCT DA TA
OUTDOOR UNIT
POWER CONNS. — V/PH/HZ MIN. BRCH. CIR. AMP A CITY 17 BR. CIR. MAX. (AMPS) 30 PROT. RTG.
NOISE RATING (DECIBELS) COMPRESSOR DURATION™
NO. USED - NO. SPEEDS 1 - 1 VOL TS/PH/HZ 200/230/1/60 R.L. AMPS F ACT ORY INST ALLED
START COMPONENTS INSULA TION/SOUND BLANKET NO COMPRESSOR HEAT YES
OUTDOOR F AN — TYPE PROPELLER DIA. (IN.) - NO. USED 18 - 1 TYPE DRIVE - NO. SPEEDS DIRECT - 1 CFM @ 0.0 IN. W.G. NO. MOTORS - HP 1 - 1/8 MOT OR SPEED R.P.M. 1075 VOL TS/PH/HZ 200/230/1/60 F.L. AMPS 0.75
OUTDOOR COIL — TYPE SPINE FIN™ ROWS - F.P.I. 1 - 24 F ACE AREA (SQ. FT.) 10.61 TUBE SIZE (IN.) 3/8
REFRIGERANT LBS. — R-22 (O.D. UNIT) FA CT ORY SUPPLIED YES LINE SIZE - IN. O.D. GAS LINE SIZE - IN. O .D. LIQ.
FCCV RESTRICTOR ORIFICE SIZE 0.065
DIMENSIONS H X W X D OUTDOOR UNIT - CRATED (IN.) 27-3/8 X 31-1/2 X 27-5/8 UNCRATED SEE OUTLINE DWG.
WEIGHT SHIPPING (LBS.) 174 NET (LBS.) 156
12
3
}
MIN. (AMPS) 30
2
7
- L.R. AMPS 13.1 - 75
8
4
5
6
6
7A0030A100A
200/230/1/60
3-LBS., 14 OZ.
78
NO
2175
3/4
5/16
1
CERTIFIED IN ACCORD ANCE WITH THE UNITARY AIR-CONDITIONER EQUIPMENT CERTIFICATION PROGRAM, WHICH IS BASED ON A.R.I. ST AND ARD 210/240.
2
RA TED IN A CCORD ANCE WITH A.R.I. STANDARD 270.
SPLIT SYSTEM
3
CALCULATED IN ACCORDANCE WITH NATL. ELECTRIC CODE. ONLY USE HACR CIRCUIT BREAKERS OR FUSES.
4
STANDARD AIR - DRY COIL - OUTDOOR
5
THIS VALUE APPROXIMATE. FOR MORE PRECISE V ALUE SEE UNIT NAMEPLATE AND SERVICE INSTR UCTION.
6
MAX. LINEAR LENGTH: 80 FT WITH RECIPROCA TING COMPRESSOR ­60 FT WITH SCROLL. MAX. LIFT - SUCTION 60 FT; MAX LIFT - LIQUID 60 FT. FOR GREATER LENGTH REFER TO REFRIGERANT PIPING SOFTWARE PUB. NO . 12-3312-01.
7
THE VALUE SHOWN FOR COMPRESSOR RLA ON THE UNIT NAMEPLATE AND ON THIS SPECIFICATION SHEET IS USED TO COMPUTE MINIMUM BRANCH CIRCUIT AMPACITY AND MAXIMUM FUSE SIZE. THE V ALUE SHOWN IS THE BRANCH CIRCUIT SELECTION CURRENT.
8
NO MEANS NO START COMPONENTS. YES MEANS QUICK START KIT COMPONENTS. PTC MEANS POSITIVE TEMPERATURE COEFFICIENT STARTER.
CONDENSING UNIT WITH COOLING COILS
CCBA30A4ACC CCBA36A4ACC CCBB30A4ACC CCBB36A4ACC CUBA30A4ACC CUBA36A4ACC CUBB30A4ACC
EXPANSION TYPE FIXED ORIFICE FIXED ORIFICE FIXED ORIFICE FIXED ORIFICE FIXED ORIFICE FIXED ORIFICE FIXED ORIFICE RA TINGS (COOLING)
BTUH (TO TAL) 26600 27400 27800 27600 26600 27400 27800 BTUH (SENSIBLE) 17400 18600 19500 19900 17400 18600 19500 INDOOR AIRFLOW (CFM) 950 1020 1000 1030 950 1020 1000 SYSTEM POWER (KW) 2.92 3.01 2.99 3.02 2.92 3.01 2.99
SEER (BTU/WATT-HR.) 10.00 10.00 10.05 10.00 10.00 10.00 10.05
EXPANSION TYPE FIXED ORIFICE CHG TO 65 CHG TO 65 CHG TO 65 CHG TO 65 CHG TO 65 CHG TO 65 RA TINGS (COOLING)
BTUH (TO TAL) 27600 26600 27000 27800 28400 28000 29000 BTUH (SENSIBLE) 19900 17200 18200 18600 19900 19000 21200 INDOOR AIRFLOW (CFM) 1030 900 900 1000 1000 1050 1085 SYSTEM POWER (KW) 3.02 2.91 2.92 3.01 3.09 3.03 3.10
SEER (BTU/WATT-HR.) 10.00 10.00 10.05 10.10 10.00 10.05 10.05
EXPANSION TYPE CHG TO 65 CHG TO 65 CHG TO 65 CHG TO 65 CHG TO 65 CHG TO 65 CHG TO 65 RA TINGS (COOLING)
BTUH (TO TAL) 29000 29400 29400 26600 26600 27000 27000 BTUH (SENSIBLE) 21200 21800 21800 17200 17200 18200 18200 INDOOR AIRFLOW (CFM) 1085 1095 1095 900 900 900 900 SYSTEM POWER (KW) 3.10 3.13 3.13 2.91 2.91 2.92 2.92
SEER (BTU/WATT-HR.) 10.05 10.10 10.10 10.00 10.00 10.05 10.05
See pages 20 and 21 for combinations with Auxiliary Devices.
1
CUBB36A4ACC TXA024C4 TXA025C4 TXA030C4 TXA031C4 TXA035C4 TXA036C4
1
TXA037C4 TXA042C4 TXA043C4 TXC024C4 TXC024D4 TXC025C4 TXC025D4
1
DATA SUBJECT TO CHANGE WITHOUT NOTICE
9