American Standard 7871.722, 7871.712, 7871.702, 7871.732, 7881.722 User Manual

...
Installation
Instructions
7871.702
7871.712
Spread Lavatory Faucet with the
Speed Connect™ Drain
Congratulations on purchasing your American Standard faucet with Speed Connect drain, a feature found only on American Standard faucets.
Speed Connect Drain*
• Fewer parts, installs in less time
• Never needs adjustment
• Guaranteed to seal properly the first time, every time.
*Your new American Standard faucet is designed to work only with the Speed Connect drain.
To ensure that your installation proceeds smoothly-please read these instructions carefully before you begin.
Recommended tools
7871.722
7871.732
7881.702
7881.712
7881.722
7881.732
Certified to comply with ANSI A112.18.1
US60404 Rev.1.2
Adjustable Wrench Screwdriver Channel Locks
INSTALL SPOUT
1
Insert SPOUT (1) and CABLE CONNECTOR (12) through center hole, making sure the SPOUT ESCUTCHEON (2) and SEAL WASHER (3) are properly seated.
Assemble RUBBER WASHER (4), BRASS WASHER (5) and LOCKNUT (6) onto SPOUT SHANK (7) from under side of sink . Make sure SPOUT (1) is centered in the mounting hole and the slot in the BRASS WASHER (5) faces toward the rear of the sink.
Tighten LOCKNUT (6) firmly. Fig. A.
1A
INSTALL VALVE BODY
Place RUBBER RING (9) into SCUTCHEON (10).
Install LOCKNUT (11) onto VALVE BODY (8). From under side of mounting surface, install VALVE BODY (8) through valve mounting holes. Threads of VALVE BODY (8) should extent at least 5/16 of a inch above mounting surface top. Fig. B. Thread ESCUTCHEON (10) onto VALVE BODY (8) until snug against internal stop. If necessary, adjust LOCKNUT (11).
Hand tighten LOCKNUT (11) to secure VALVE BODY (8). Repeat above steps for opposite VALVE BODY (8A).
CAUTION
10
9
5/16'' MIN.
Turn off hot and cold water supplies before beginning.
10
MOUNTING SURFACE
9
Tubing Cutter
Fig. A.
1
2 3
7
4
SLOT
5
6
12
1
8A
Fig. B.
11
8
8
11
7871 SERIES
1
POP-UP DRAIN
2
Fig. A. Fig. B.
Remove CLEAR PLASTIC COVER (1).
Remove CARDBOARD SPACER (2) from under DRAIN POP-UP (3).
Tighten TAILPIECE (4) on DRAIN BODY before installing DRAIN BODY.
REMOVE FLANGE
3
Thread FLANGE (1) counter-clockwise and remove FLANGE (1) and FOAM GASKET (2) from drain body.
Fig. A.
Thread LOCKNUT (3) clock-wise to bottom of drain body. Push GASKET (4) down against LOCKNUT (3).
Fig. B.
Fig. B.
1
3
2
Fig. A. Fig. B.
1
2
4
3
DRAIN BODY
4
INSTALL DRAIN FROM
4
BELOW FIXTURE
From under side of SINK install DRAIN BODY (1) up through drain outlet.
Note: No plumber’s putty or caulk is required. The CABLE ATTACHMENT POINT (2) must face towards the rear of the SINK.
Install FOAM GASKET (3) and FLANGE (4) onto drain body from above SINK and tighten FLANGE (4) firmly.
FLANGE GASKET AND POP-UP KNOB
6
Check DRAIN FLANGE in SINK to ensure that WHITE FOAM GASKET (3) is fully compressed and not visible. Fig. A.
POP-UP KNOB (1) must be fully down. Fig. B.
REAR OF SINK
4
DRAIN OUTLET
TIGHTEN LOCKNUT
5
Tighten LOCKNUT (1) firmly with Adjustable Wrench or Channel Locks.
3
1
1
2
Fig. A. Fig. B.
DOWN
1
WHITE FOAM GASKET NOT VISIBLE
DRAIN FLANGE
US60404 Rev.1.2
2