American Standard 7820.800 User Manual

7301050-100 Rev.C
P ro d u ct na m e s l i s te d he r ei n ar e t r a de m a r ks o f A m e ri c an S ta n da r d I n c. © A m e ri c an S ta n d a rd I nc . 2 0 0 7
ASSEMBLY & INSTALLATION INSTRUCTIONS
Cascada 30" Vanity
Newbern Vanity Top
7820.800
- 1 -
Recommended Tools & Materials
Roughing-in Dimensions
Thank you for selecting our products...products which have been the benchmarks of fine quality for over 100 years. To help insure that the installation process will proceed smoothly, please read these instructions carefully before you begin. Also, review the recommended tools and materials list; carefully unpack and examine your new plumbing fixture.
Adjustable Wrench
Channel Locks
Phillips Screwdriver
Putty Knife
Regular Screwdriver
Drill
Saber Saw
Level
Basin Wrench
Plumbers' Putty or Caulking
Tubing Cutter
10'
Tape Measure
Hacksaw
Pipe Wrench
21"
533mm
30"
762mm
34"
864mm
22-3/4"
578mm
26-3/4"
679mm
6"
(152mm)
1-1/4" O.D.
WASTE
SUPPLIES AS REQ'D
FINISHED FLOOR
To maintain the beauty of the finish, avoid placing the furniture in direct sunlight, as sunlight causes fading. Also avoid extreme changes in temperature by arranging furniture away from radiators, heat and air vents, and air conditioning units. Avoid placing furniture directly under windows.
- 2 - - 3 -
C/L of 2 x 6 Reinforcement
Finished Floor
27-3/4"
Provide suitable reinforcement required for anchoring the vanity to the wall. Centerline of reinforcement should be 27-3/4" up from the floor (see Figure 1).
Open vanity drawers. Remove screws from inside drawers and pull drawers off drawer glides. (see Figure 2).
If molding is present, it will need to be notched to set the vanity flush against the wall. (see Figure 3).
Rough in supply lines and waste per rough in dimensions.
NOTE:
If current supply lines are greater than 6" on center,
they may interfere with cutout in rear of vanity or vanity shelf.
Move the vanity into place and level with the adjustable glides on the bottom of the feet. The glides can be adjusted outward up to 3/4" but it is recommended not to exceed 1/2" if possible. Anchor it to the wall through at least 2 of the anchoring holes in the rear of the vanity (see Figure 4).
Installing the Newbern Top…
Two people recommended for this installation
Mount the drain assembly (not included) on the sink. Be certain to apply a bead of sealing putty on the underside of the drain (Part "A") in order to ensure a watertight seal between the sink and drain. Remove excess putty after installing the drain on the sink.
Apply a bead of silicone adhesive to the rim of the vanity. Place the Newbern top centered left to right on the vanity and with the back edge of the top even with the rear of the vanity. Clean up any excess silicone.
Place top back on vanity and, connect the trap to the drain assembly hand tight to check alignment. It may be necessary to cut off part of the tailpiece (area "B") or part horizontal leg of the trap (area "C").
Connect hot and cold supply lines to the shut off valves. Tighten trap joints for watertight assembly.
A
B
C
VANITY INSTALLATION
MOLDING
ADJUSTABLE GLIDES (LOCATED UNDER EACH FOOT)
FIGURE 1
FIGURE 3
21
(533mm)
C/L
27-1/2" 578mm
Using a 3/8" O.D. drill, drill 3 anchoring holes, equally spaced, in back support of vanity (see Figure 4).
Continue with installation appropriate for top and sink options chosen.
FIGURE 4
ANCHORING
HOLES (3)
FIGURE 2
DRAWER
REMOVE SCREWS
Loading...