Installation
TM
Williamsburg
Instructions
7391.229
7391.224
BIDET FITTING
Thank you for selecting American-Standard...the benchmark
of fine quality for over 100 years.
To ensure that your installation proceeds smoothly--please
read these instructions carefully before you begin.
Roughing-in Dimensions
TRANSFER VALVE (FOR FLUSHING
BIDET OUTLINE
IS SYMBOLIC
CARE INSTRUCTIONS:
DO: SIMPLY RINSE THE PRODUCT CLEAN
WITH CLEAR WATER. DRY WITH A SOFT
COTTON FLANNEL CLOTH.
DO NOT: CLEAN THE PRODUCT WITH SOAPS,
ACID, POLISH, ABRASIVES, HARSH CLEANERS,
OR A CLOTH WITH A COARSE SURFACE.
DOUCHE SPRAY
3-7/8
RIM OR SPRAY)
7/8 DIA.
ADJ. 1-1/4
TO 2-1/4
1-3/8
DIA.
5-1/2
2-1/8
DIA.
FINISHED
WALL
1-1/4 O.D. TAILPIECE
1-3/16 DIA.
1-1/4 MAX.
FINISHED
FLOOR
Certified to comply with ASME A112.18.1M
U.S. Patent No. 5,819,789
M968032A
8 TO 12
(C)
DIVERTER AND
VACUUM BREAKER
ASSEMBLY
(H)
2-1/4
DIA.
FOR GROUND JOINT
CONNECTION OR 1/2 "
O.D. SLIP (INLETS)
REAR VIEW WITH
WALL REMOVED
4-1/4
BIDET FAUCET INSTALLATION
1
CAUTION
Place MOUNTING NUTS (1) onto the VALVE BODIES
(2) and insert VALVE BODIES (2) through outside
holes, from underside of the BIDET LEDGE. Drop the
RUBBER RING (3) over the VALVE BODIES (2) and
screw on the ESCUTCHEON (4) until it locks against
the internal stop.
Tighten the MOUNTING NUT (1) to secure the
VALVE BODY (2).
Remove MOUNTING NUT (9) and UPPER GASKET (7)
from TRANSFER VALVE (8) and insert into the center
forward hole of BIDET.
Replace UPPER GASKET (7). Position the side threaded
outlet rearward and secure MOUNTING NUT (9).
Thread ESCUTCHEON (5) onto TRANSFER VALVE (8)
until it seats against the BIDET LEDGE.
Turn off hot and cold water
supplies before beginning.
5
9
4
3
BIDET
LEDGE
HOT
1
COLD
7
8
DRAIN INSTALLATION
2
Assemble O-RING (1), WASHER (2), PIVOT ROD (3)
and NUT (4) to DRAIN BODY (5). Concave side
of cup WASHER (2) is toward ball.
Thread LOCKNUT (6), WASHER (7) and
GASKET (8) onto DRAIN BODY (5).
Apply a bead of PUTTY to underside
of FLANGE (9).
Feed DRAIN BODY (5) up through BIDET
and thread FLANGE (9) fully onto
BODY (5).
Tighten LOCKNUT (6) firmly, keeping the
PIVOT ROD (3) pointed towards the back
of the BIDET.
Push DRAIN ESCUTCHEON (10) onto
TAILPIECE (11).
8
7
6
STOPPER
PUTTY
2
5
9
4
BIDET
1
11
CLIP
3
10
SPRAY INSTALLATION
3
Assemble SPRAY BODY (1) to BIDET.
Using putty, seal underside of SPRAY
BODY FLANGE (2) and secure with
2
NUT (3).
Screw SPRAY HOSE (4) with SEAL
WASHER (5) to SPRAY BODY (1).
Connect other end of HOSE (4) with
SEAL WASHER (5) to side outlet
NIPPLE (6) of the TRANSFER VALVE (7).
Screw SPRAY CAP (8) onto SPRAY BODY (1).
7
6
5
2
PUTTY
7
8
1
3
5
4
LIFT ROD GUIDE INSTALLATION
4
Unscrew LIFT ROD NUT (1)from LIFT ROD GUIDE (2).
Make sure SEAL (3) is seated into ESCUTCHEON of
LIFT ROD GUIDE (2).
Drop LIFT ROD GUIDE (2) into
rear hole of bidet and from
below secure with ROD GUIDE
NUT (1).
3
TEE AND HOSE CONNECTION
5
Insert SEAL (1) into ADAPTER (2)
and tighten ADAPTER (2) to bottom
of TRANSFER VALVE (3).
Install SEAL (4) into coupling nut
of TEE (5) and tighten connection
to ADAPTER (2)
2
1
Connect HOSE COUPLING
NUTS (6) to Hot and Cold
valve bodies and securely
tighten.
2
4
6
3
1
6
5
HANDLE INSTALLATION
6
Push ADAPTER (1) on VALVE STEM (2), so that the hole of the
ADAPTER (1) without spline is facing up. See figure "A".
Screw HANDLE BASE (3) on top of ESCUTCHEON (4) until it is snug
against stop.
Push LEVER BALL (5) through HANDLE BASE (3) onto ADAPTER (1).
Find correct position of LEVER BALL (5) by adjusting male teeth on
ADAPTER (1) to female teeth in LEVER BALL (5).
Secure LEVER BALL (5) with HANDLE SCREW (6).
Push INDEX CAP (7) in hole of LEVER BALL (5).
TOP
Figure "A"
SPLINE END DOWN
FINISH DRAIN INSTALLATION
8
Position BIDET fixture and
secure to floor.
Insert lift rod into lift rod guide.
Position EXTENSION ROD (1)
onto POP-UP ROD (2) and tighten
THUMBSCREW (3).
Remove one end of CLIP (4) from
PIVOT ROD (7) by squeezing ends
together while sliding.
Insert PIVOT ROD (7) into second
or third hole in EXTENSION ROD (1)
and reassemble CLIP (4).
(EXTENSION ROD (1) may need to be bent.)
Adjust STOPPER height by repositioning EXTENSION ROD (1) and
tightening THUMBSCREW (3).
Using metal TAILPIECE (5), make connection to the TRAP (6).
2
3
1
5
6
WATER SUPPLY CONNECTIONS
7
NOTE: FLEXIBLE SUPPLIES ARE NOT INCLUDED AND HAVE TO BE
PURCHASED SEPARATELY.
Connect water supplies to FAUCET (1) with 1/2" IPS
FLEXIBLE SUPPLIES (2) or 3/8" O.D. BULL-NOSE RISERS (3).
Use adjustable wrench to tighten connections.
Do not over tighten. Be careful not to kink copper supply
when bending. Use tubing cutter to cut to proper length.
1
7
6
5
3
SERVICE
1
2
4
1
9
To change direction of handle rotation, proceed as follows:
Turn valve to OFF position.
Remove INSERT and HANDLE SCREW.
Slip HANDLE with ADAPTER off.
Remove SPRING CLIP (1).
Lift STOP WASHER (2), turn 90° and replace.
Replace SPRING CLIP (1).
Replace ADAPTER, HANDLE, SCREW, and INSERT.
Spray may accumulate dirt
causing distorted and reduced
water flow. Remove spray and
7
rinse clean.
Replace Spray and operate
handles several times from
OFF to ON position. Do not
force, handles turn only 90˚.
2
3
COUPLING NUT
FERRULE
2
90°
1
4
10
TEST INSTALLED FAUCET
With handles in OFF position, turn on water supplies and
check all connections for leaks.
Operate both handles to flush water lines thoroughly. Turn
diverter to rim wash and bidet spray.
M968032A