Congratulations on purchasing your American Standard
faucet with Speed Connect drain, a feature found only on
American Standard faucets.
Speed Connect Drain*
• Fewer parts, installs in less time
• Never needs adjustment
• Guaranteed to seal properly the first time, every time.
*Your new American Standard faucet is designed to work only with the Speed Connect drain.
To ensure that your installation proceeds smoothly-please read these instructions carefully before you begin.
Required tools
7385.00X
Certified to comply with ANSI A112.18.1
M968889 Rev. 1.2
INSTALL FAUCET
1
Turn off hot and cold water supplies before beginning.
Insert FAUCET (1) and CABLE CONNECTOR (2) through
mounting holes of Sink or Mounting Surface.
Assemble LOCKNUTS (3) onto SHANKS (4) from under
side of Sink. Hand tighten firmly.
CAUTION
Turn off hot and cold water
supplies before beginning.
1
Adjustable Wrench ScrewdriverChannel Locks
Tubing Cutter
4
SINK OR
MOUNTING
SURFACE
(HAND TIGHTEN)
3
POP-UP
CABLE
2
1
Page 2
POP-UP DRAIN
2
Fig. A.Fig. B.
Remove CLEAR PLASTIC COVER (1).
Remove CARDBOARD SPACER (2) from under
DRAIN POP-UP (3).
Tighten TAILPIECE (4) on DRAIN BODY before
installing DRAIN BODY.
REMOVE FLANGE
3
Thread FLANGE (1) counter-clockwise and remove
FLANGE (1) and FOAM GASKET (2) from drain
body.
Fig.A.
Thread LOCKNUT (3) clock-wise to bottom of
drain body. Push GASKET (4) down against
LOCKNUT (3).
Fig. B.
Fig. B.
1
3
2
Fig. A.Fig. B.
1
2
4
3
DRAIN
BODY
4
INSTALL DRAIN FROM
4
BELOW FIXTURE
From under side of SINK
install DRAIN BODY (1) up
through drain outlet.
Note: No plumber’s putty
or caulk is required.
The CABLE ATTACHMENT
POINT (2) must face towards
the rear of the SINK.
Install FOAM GASKET (3) and
FLANGE (4) onto drain body
from above SINK and tighten
FLANGE (4) firmly.
FLANGE GASKET AND POP-UP KNOB
6
Check DRAIN FLANGE in SINK to ensure that
WHITE FOAM GASKET (3) is fully compressed
and not visible. Fig.A.
POP-UP KNOB (1) must be fully down. Fig.B.
4
3
TIGHTEN LOCKNUT
REAR OF SINK
DRAIN
OUTLET
5
Tighten LOCKNUT (1) firmly with Adjustable
Wrench or Channel Locks.
1
2
Fig. A.Fig. B.
WHITE FOAM
GASKET
NOT VISIBLE
DRAIN
FLANGE
1
DOWN
1
M968889 Rev. 1.2
2
Page 3
ATTACH CABLE CONNECTOR
7
Thread CABLE CONNECTOR (1) clockwise
onto DRAIN BODY CONNECTION (2) and
hand tighten. Fig. A.
Your new POP-UP DRAIN installation is
now complete. Fig.B.
Note: Tailpeice on pop-up drain is 1-1/4” O.D.
Fig. B.
Fig. A.
Fig. B.
1
CHECK OPERATION OF POP-UP
8
Operate LIFT KNOB (1) to verify that STOPPER (2) opens and
closes.
Note: If STOPPER (2) does not open and close properly then refer
to the “troubleshooting section” of these instructions.
MAKE WATER SUPPLY AND WASTE CONNECTIONS
9
Connect FLEXIBLE SUPPLIES (1, 2) directly to wall supplies.
Connection on fitting supplies are 3/8" compression. Connect
left SUPPLY (1) to Hot (Marked with a Red Band) and right supply
to COLD (2) wall supply.
2
1-1/4” O.D.
1
2
Faucet supplies are 20" long from faucet base.
Note: If additional supply length is required, installer must
purchase additional parts separately.
Important: If SUPPLY HOSES (1, 2) are to long, loop as
illustrated to avoid kinking.
Connect 1-1/4” O.D. tailpiece on POP-UP DRAIN to
waste outlet.
3
APPROX. 20"
1
HOT
RED
BAND
2
BLUE
BAND
3/8" COMPRESSION
COLD
M968889 Rev. 1.2
Page 4
10
0
1
2
3
4
5
6
7
TEST INSTALLED FITTING
With HANDLE (1) in OFF position, turn on WATER
SUPPLIES (2) and check all connections for leaks.
ON
OFF
1
COLD
Remove AERATOR (3).
Operate HANDLE (1) to flush water lines thoroughly.
Replace AERATOR (3).
CHECK DRAIN CONNECTIONS
Operate POP-UP KNOB (4) and fill lavatory with water.
Check that DRAIN STOPPER (5) makes a good seal
and retains water in Sink. If DRAIN STOPPER (5)
does not seal properly, please refer to Troubleshooting
section in these instructions.
Release POP-UP KNOB (4) down and check all drain
connections and "P" trap for leaks. Tighten
if necessary.
4
WASTE
OUTLET
HOT
3
5
2
“P” TRAP
11
2
SERVICE
By restricting handle rotation and limiting the amount of hot water allowed to mix with the cold, the HOT LIMIT SAFETY STOP
reduces risk of accidental scalding. To set the maximum hot water temperature of your faucets, all you need to do is adjust
the setting on the HOT LIMIT SAFETY STOP.
Loosen SET SCREW (2) with 2.5mm hex wrench. Pull HANDLE (1) off valve stem. Pull off
CAP (3). Use a flat blade screwdriver or your fingers to pull up and rotate red HOT LIMIT
SAFETY STOP (4). Follow Step "A" or "B" to adjust min./max. discharge temperature. "0"
being the hottest to "7" the coldest temperature setting. Factory set at "0".
Replace ESCUTCHEON CAP (3), HANDLE (1), tighten HANDLE SCREW (2).
PRY RED RING FORWARD
AND ROTATE COUNTER-
"A"
CLOCKWISE ONE CLICK
"A"
TEMPERATURE
SETTING NUMBERS
"B"
PRY RED RING FORWARD
AND ROTATE CLOCKWISE
"B"
ADJUSTMENT WHEN
WATER IS TOO COLD
"B"
"RED RING"- HOT
LIMIT SAFETY STOP
"A"
ADJUSTMENT WHEN
WATER IS TOO HOT
4
1
2
3
12
CARE INSTRUCTIONS:
DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.
DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A
CLOTH WITH A COARSE SURFACE.
4
M968889 Rev. 1.2
Page 5
SpeedConnect™ Drain
Troubleshooting Guide
If sink does not hold water even though Stopper is in the “down” position:
• Follow CABLE ADJUSTMENT PROCEDURE.
If Stopper does not raise up fully or sink drains too slowly:
• Follow CABLE ADJUSTMENT PROCEDURE.
If you need to remove the Stopper:
• Follow STOPPER REMOVAL PROCEDURE.
If you would like the ability to remove your Stopper simply by lifting it out of the drain:
• Follow STOPPER INSTALLATION PROCEDURE for “Unlocked” mode.
CABLE ADJUSTMENT PROCEDURE
Disconnect the Cable from the Drain by threading the Cable Connector (1) counter-clockwise. Fig.A.
Look at the area on the Drain Body where the Cable was attached and locate the component labeled as
“Cam” in the illustration. Fig. B.
Use a small screwdriver to rotate the Cam in the clockwise direction as far as it will go. At this point the
Stopper should be in the UP position. Fig. B, C.
Push DOWN on the Lift-Knob to make sure it is fully down. Fig.C.
Re-attach the Cable to the Drain Body Connection (2) by threading the Cable Connector (1) clockwise onto the
Drain Body Connection (2) and hand-tighten. Fig.A.
1
RE-ATTACH
DISCONNECT
Fig. B.Fig. A.
CAM
CAM CAP
Fig. C.
STOPPER
2
STOPPER REMOVAL PROCEDURE
Disconnect the Cable from the Drain by threading the Cable Connector (1) counter-clockwise. Fig.A.
Look at the area on the Drain Body where the Cable was attached and locate the component labeled
as “Cam” and “Cam Cap” in the illustration. Fig.B.
Use fingers or small screwdriver under either side of the Cam Cap to pry it out from the Drain. Fig.D.
Remove the Cam by pulling it straight out while wiggling gently to loosen the Rubber Seal. Fig.E.
The Stopper can now be removed by lifting it out of the Drain. Fig.F.
Fig. D.
Fig. E.
REMOVE
CAM
1
DOWN
Fig. F.
REMOVE
CAM CAP
M968889 Rev. 1.2
5
Page 6
STOPPER INSTALLATION PROCEDURE
The Stopper can be installed two ways, “Locked” Mode (Stopper cannot be
removed) or “Unlock” Mode (Stopper is removable).
Locked Mode:
Look at the Plastic Loop at the bottom of the Stopper and notice
that the Loop is on one side of the Stopper. Fig.G.
Fig.G.
To install the stopper in “Locked” mode, insert the Stopper into
the Drain so that the Plastic Loop is facing toward the rear of the
Sink and the American Standard logo is facing front. Rotate
Stopper slightly if necessary so that the Stopper slides all the
way down.Fig.G.
Re-install the Cam into the Drain, rotating the Cam if necessary
to make sure it is fully inserted. Fig.J.
LOGO
Re-install the Cam Cap, making sure the guide teeth are facing
outward. If the Cam Cap does not “snap” into place, then rotate
the Cam to make sure it is fully inserted. Fig.K.
Re-attach Cable. See “CABLE ADJUSTMENT PROCEDURE” in
Troubling Shooting Guide to complete installation. Stopper will be
in “Locked” mode and not be removable.
Unlocked Mode:
Look at the Plastic Loop at the bottom of the Stopper and notice
that the Loop is on one side of the Stopper. Fig.H.
To install the stopper in “Unlocked” mode, insert the Stopper into
the Drain so that the Plastic Loop is facing toward the front of the
Sink and the American Standard logo is facing rear. Rotate Stopper
slightly if necessary so that the Stopper slides all the way down.
Fig.H.
Re-install the Cam into the Drain, rotating the Cam if necessary
to make sure it is fully inserted. Fig.J.
Re-install the Cam Cap, making sure the guide teeth are facing
outward. If the Cam Cap does not “snap” into place, then rotate
the Cam to make sure it is fully inserted. Fig.K.
Re-attach Cable. See “CABLE ADJUSTMENT PROCEDURE” in
“Troublingshooting Guide” to complete installation. Stopper will be
in “Unlocked” mode and removable
.
LOOP TOWARD
REAR OF SINK
DRAIN
Locked Mode
(Vandal Proof)
Fig. H.
LOGO
LOOP TOWARD
FRONT OF SINK
DRAIN
Unlocked Mode
Fig. J.Fig. K.
INSTALL CAM
CAM
INSTALL
CAM CAP
M968889 Rev. 1.2
6
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.