EVOLUTION™ 6' X 36"
Comfortable bathing design with form-tted
backrest and molded-in armrests
EVOLUTION™ 6' X 36"
WHIRLPOOL AND BATHING POOL
HIGH GLOSS
❏ 7236VC Whirlpool w/EverClean
®
System
• EverClean® System
• Acrylic with berglass reinforcement
• 2.1 HP self-draining pump/motor
• Ten ow adjustable jets including:
- Two adjustable Comfort Jets™ Hi Flo
- Eight adjustable Comfort Jets™
• Three silent air volume controls
• Side-mounted On/Off control
• Deep Soak Overow Drain for maximum
water depth
• Complete factory installed and tested
whirlpool system
• Self leveling feet
• Undermount installation option
• Quick connect whirlpool heater system
(must order whirlpool heater separately)
❏ 7236V Whirlpool
• Same as above without the EverClean® System
❏ 7236V.002 Bathing Pool
Nominal Dimensions:
72" x 36" x 21-1/4"
(1829 x 914 x 540mm)
American Standard whirlpools with EverClean®
incorporate a patented silver-ion additive right
into the circulation piping to protect the pipes
from mold, mildew, algae and fungus that could
cause deterioration or staining of the pipes.
Compliance Certications Meets or Exceeds the Following Specications:
• Underwriters Laboratories - Hydromassage
Bathtubs UL 1795
• ASME A112.19.7M for Whirlpool Appliances
• ANSI Z124.1 for Plastic Bathtubs
• ASTM E162 for Flammability
• NFPA 258 for Smoke Density
SEE REVERSE FOR ROUGHING-IN DIMENSIONS
AND PRODUCT SPECIFICATIONS
Components Required:
❏ Bath Filler*: (specify nish)
❏ Bath Drain: 1599.205.XXX (specify color)
Custom Accessories Available:
❏ Six Foot Apron: 9271.019.XXX (specify color)
❏ Safe-T-Heater Whirlpool Heater: 9075.120
❏ Tile Bead Kit: 751755-100
* See American Standard Faucet Selector
For color/nish availability and other faucet choices, please
see the Product Selector and Pricing Guide.
NOTE: Whirlpool Heater is designed to maintain water
temperature during operation. It will not heat cold water to
desired bathing temperature.
© 2008 AS America Inc.
H95
Revised 4/06
EVOLUTION™ 6' X 36"
GENERAL SPECI FICATI ONS FO R 7236V WHIRL POOL
WHIRLPO OL ELE CTRICA L SPEC IFICATI ONS
PUM P
72 x 3 6 x 21 -1/2 I n. (18 29 x 914 x 546mm)
106 Lb s. (48 Kg.)
1031 L bs. (4 67 Kg. )
111 Ga l. (42 0 L)
53 Gal . (201 L)
53-1/2 x 26- 1/4 In . (135 9 x 667mm)
64-1/2 x 30 In. (1 638 x 762mm)
18-1/2 In.(4 70mm)
57 Lb s./Sq. Ft. (2 80 Kgs ./Sq.m)
2.1 H P, 14 .4 AMPS ,1 20 V.
INS TA LL ED S IZE
WEI GH T
WEI GH T w/ WA TER
GAL . TO O VE RFLOW
WHI RL PO OL M IN. O PE RA TI NG V OL.
BAT HI NG W EL L AT SU MP
BAT HI NG W EL L AT RI M
WAT ER D EP TH TO O VE RF LO W
FLO OR L OA DI NG
(PR OJ EC TE D AREA)
36"
(914mm)
21-1/2"(H)
(546mm)
20"(C)
(508mm)
20-1/8"(A)
(511mm)
DIMENSIONS OF FIXTURES ARE NOMINAL AND MAY VARY WITHIN THE RANGE
OF TOLERANCES ESTABLISHED BY ANSI STANDARDS Z124.1 AND A112.19.7.
C/L OF
OVERFLOW
72"
(1829mm)
36"
(914mm)
7-3/4"
(197mm)
11"
(279mm)
3"
(76mm)
3-1/4"
(83mm)
6"
(152mm)
13-3/4"
(349mm)
CUT OUT IN FLOOR
FOR DRAIN
GENERAL SPECIFICATIONS FOR 7236V BATHING POOL
72 x 36 x 21-1/2 (1829 x 914 x 546mm)
91 Lbs. (41 Kg.)
1016 Lbs. (461 Kg.)
111 Gal. (420 L.)
53-1/2 x 26-1/4 In. (1359 x 667mm)
64-1/2 x 30 In. (1638 x 762mm)
18-1/2 (470mm)
56 Lbs./Sq.Ft. (275 Kgs./Sq.m)
INSTAL LED SI ZE
WEIGHT
WEIGHT w/WAT ER
GAL. T O OVER FLOW
BATHIN G WELL AT SU MP
BATHIN G WELL AT RI M
WATER DEPTH TO OVE RFLOW
FLOOR LOADIN G
(PROJE CTED A REA)
WHIRLPOOL AND BATHING POOL
HIGH GLOSS
NOTES:
BATH CAN BE INSTALLED EITHER ABOVE OR BELOW FLOOR LINE AS PIER, ISLAND OR PENINSULA T YPE INSTALLATION. SUMP
OF BATH IS SUPPORTED BY INTEGRAL FEET. NO ADDITIONAL SUPPORT REQUIRED. ENCLOSING MATERIAL BY OTHERS.
■REFER TO INSTALLATION INSTRUCTIONS SUPPLIED WITH WHIRLPOOL, DECK MOUNTED SPOUT AND INTEGRATED BATH
FILLER FOR ADDITIONAL INFORMATION.
OPTIONAL 3-WALL TILING BEAD KIT No. TILE-BEAD AND APRON No. 6FT-APRON MUST BE ORDERED SEPARATELY.
PROVIDE SUITABLE REINFORCEMENT FOR ALL SUPPORTS.
© 2008 AS America Inc.
IMPORTANT: Dimensions of xtures are nominal and may vary within the range of tolerances established by ANSI Standard Z124.1
These measurements are subject to change or cancellation. No responsibility is assumed for use of superseded or voided leaet.
H96