•Easy installation. All electronics in the spout; nothing below deck.
•User adjustable above-deck mixing uses ceramic disc
valve for dependability & long life
•Mixing handle can be removed for one time temperature
setting during installation
•Available in DC (Battery) & AC versions
Platform with Universal Sensor
7056.105
7056.115
7056.205
7056.215
Product No.'s & Options
Specifications
How to Install
Maintenance
FAQ,s
Replacement Parts
M 9 6 52 5 5 RE V. 1.6
Installation Instructions
NOTE TO INSTALLER: Please give this manual to the customer after installation.
To l ea r n mo re a bo u t A me ri c an S ta nd ar d Fa u ce ts v i si t ou r we b si te at : www.americanstandard-us.com
or U.S. customer's e-mail us at: faucetsupport@americanstandard.com
For Parts, Service, Warranty or other Assistance,
please call
1-800-442-1902 (In Canada: 1-800-387-0369)
(In Toronto Area only: 1-905-3061093)
(In Toronto Area only: 1-905-3061093)
Page 2
Thank you for selecting American-Standard...the benchmark of fine quality for over 100 years. To ensure
In sta lla ti on Ins tru cti on s
In sta lla ti on Ins tru cti on s
that your installation proceeds smoothly--please read these instructions carefully before you begin.
UNPACKING
All American Standard Faucets Are Water Tested At Our Factory.
Some Residual Water May Remain In The Faucet During Shipping.
1. R e mo v e t he f i tt i n g a nd l o os e i t e ms f r o m t h e c a r to n . T h e i l l u s t ra t i o n be l o w s h o w s t h e f it t in g a n d al l l o o s e i t e m s
after they have been removed from the carton. Some items may be packaged partially assembled to other items.
1. Selectronic Spout Assembly
2. Mounting Kit
3. Battery (7055 Series)
3a. AC Power Supply (7056 Series)
4. 4" Deck plate (optional must be ordered separately)
5. Mixing Valve (optional must be ordered separately)
6. Key for vandal resistant aerator
7. Installation Instructions
8. Hose Adapters
Less MixingWith Above-Deck Mixing
PRODUCT No.sPRODUCT No.s
7055.105
7055.115
7056.105
7056.115
6
DO NOT REMOVE
PROTECTIVE FILM
FROM SENSOR EYE
UNTIL INSTALLATION
IS COMPLETE.
7055.205
7055.215
7056.205
7056.215
6
DO NOT REMOVE
PROTECTIVE FILM
FROM SENSOR EYE
UNTIL INSTALLATION
IS COMPLETE.
®
SELECTRONIC
Proximity Integrated Faucet
with Optional Above-Deck Mixing
®
Platform with Universal Sensor
•Flexible Selectronic
•Easy installation. All electronics in the spout; nothing below deck.
•User adjustable above-deck mixing uses ceramic disc
valve for dependability & long life
•Mixing handle can be removed for one time temperature
setting during installation
•Available in DC (Battery) & AC versions
Product No.'s & Options
Specifications
How to Install
Maintenance
FAQ,s
Replacement Parts
M965255 REV. 1.6
Installation Instructions
NOTE TO INSTALLER: Please give this manual to the customer after installation.
To lea r n m o r e a bo u t A me r i ca n St a nd a rd Fa u c et s v i s it ou r we b si t e a t : www.americanstandard-us.com
or U.S. customer's e-mail us at: faucetsupport@americanstandard.com
For Parts, Service, Warranty or other Assistance,
please call
•Easy installation. All electronics in the spout; nothing below deck.
•User adjustable above-deck mixing uses ceramic disc
valve for dependability & long life
•Mixing handle can be removed for one time temperature
setting during installation
•Available in DC (Battery) & AC versions
Product No.'s & Options
Specifications
How to Install
Maintenance
FAQ,s
Replacement Parts
M965255 REV. 1.6
Installation Instructions
NOTE TO INSTALLER: Please give this manual to the customer after installation.
To lea r n m o r e a bo u t A me r i ca n St a nd a rd Fa u c et s v i s it ou r we b si t e a t : www.americanstandard-us.com
or U.S. customer's e-mail us at: faucetsupport@americanstandard.com
For Parts, Service, Warranty or other Assistance,
please call
Electronic faucet with proximity operation. Vandal
resistant solid brass construction single post mounting.
Operates on DC (battery) or AC power. Inlets 3/8"
compression, built-in checks, flexible stainless steel 18"
reach inlet hoses for spout connection and In-line
integral strainer for solenoid.
2. Installation with ESCUTCHEON (1) (optional). Apply a
bead of putty to bottom edge of ESCUTCHEON with PUTTY
PLATE (1). (Only if mounting surface is uneven).
3. Insert supply HOSES (2), SHANK (3) and POWER CORD
(10) (if equipped) through hole in ESCUTCHEON with PUTTY
PLATE (1) and mounting surface. Follow mounting
instructions below to secure faucet to mounting surface.
(Make sure PIN (7) is in back).
4. Installation less ESCUTCHEON (1). IMPORTANT: Do not
use putty when installing faucet without escutcheon.
5. Assemble RUBBER WASHER (4), BRASS WASHER
(5) and THREADED LOCKNUT (6) onto SHANK (3) from
underside of sink or mounting surface. Hand tighten
LOCKNUT (6).
6. Use a screwdriver to tighten SCREWS (8) on
LOCKNUT (6). Work your way around LOCKNUT (6),
tightening the screws slightly each time until all are snug
to ensure even pressure.
CONNECT POWER SUPPLY; Fig. 1a
2
CAUTION
(7056 series only)
1. Connect the sensor cable (1) to the POWER SUPPLY CABLE (2).
Turn off hot and cold water
supplies before beginning
3. Connect left supply (Marked with a Red Stripe) to
Hot and right supply (Marked with Blue Stripe) to Cold
supply. Use adjustable
wrench to tighten connections. Do not over tighten.
4. Faucet supplies are 18" long from faucet base.
Note; If additional supply length is required,
installer must purchase those parts separately.
Important; If SUPPLY HOSES (1, 2) are too long,
loop as illustrated to avoid kinking.
INSTALL OPTIONAL MIXING
4
VALVE; Fig. 3
For 7055.105/115 & 7056.105/115 Faucets.
Note; For complete detailed installation and
operating instructions see installations
instructions supplied with mixing valve.
No. M968808
NOTE TO INSTALLER: Please give this manual to the customer after installation.
To le a r n m or e ab o ut Am e r ic a n S t an d ar d F a uc e ts v is i t o u r w e bs i te at : www.us.amstd.com or U.S.
customer's e-mail us at: faucetsupport@amstd.com
For Parts, Service, Warranty or other Assistance,
1-800-442-1902 (In Canada: 1-800-387-0369)
please call
Replacement Parts
(In Toronto Area only: 1-905-3061093)
(In Toronto Area only: 1-905-3061093)
2
SEAL
WASHER
(SUPPLIED)
1
2
3
3
4
MAINTENANCE
HAND WASH SENSOR OPERATION;
1
Fig. 1
REMOVE PROTECTIVE FILM FROM SENSOR EYE
WHEN INSTALLATION IS COMPLETE.
When the Sensor detects a user, the water
immediately starts to flow. Water flow will stop two
seconds after user is out of sensor range. The off delay
allows the user to comfortably move his hands without
the flow cycling on to off. As a precaution, a safety
timer will turn off the water, after the sensor has been
blocked for 59 seconds. The water will stay off until the
blockage is removed from the detection zone.
Detection Zone: 2" - 10" (50.8mm - 254mm)
Default: Set at Factory 6" (152.4mm)
3
Fig. 1
DETECTION
ZONE
PROTECTIVE FILM
M965255 REV. 1.6
Page 5
2
HOW TO CHANGE SENSOR
RANGE; (Factory set at 6") Fig. 2
1. Setting the Detection Zone (Distance):
Remove the FAUCET COVER (1) by unthreading the
LEVER SCREW (2) and pulling off the LEVER
HANDLE (3). Unthread the FAUCET COVER SCREW
(4) at the back of the FAUCET. Pull FAUCET COVER
(1) up and off. Fig. 2.
Fig. 2
REMOVE
1
REPLACE
2. Disconnect the BLACK POWER SUPPLY
CONNECTOR (1) and reconnect. Fig. 3.
3. While the SENSOR CONTROL LED (2) is blinking
slowly, place your hand 1 - 2 in. (25.4-50.8mm) in front
of the sensor. Fig. 4.
4. When the LED stops blinking and stays "ON", move
your hand to the desired position and hold in place until
the LED begins to blink again. Fig. 4a.
5. Once the SENSOR CONTROL LED (2) begins to
blink again, remove your hand from the detection zone.
When the flashing stops, the detection distance is set.
6. Replace FAUCET COVER (1) and LEVER HANDLE
(3). I nstall LEVER HANDLE SCREW (2), FAUCET COVER SCREW (4) and tighten. Fig. 2.
Fig. 3
3
2
4
1
Fig. 4Fig. 4a
1"-2"
(25.4mm-
50.8mm)
2
BLINKING LED
4
2
BLINKING LED
UP TO 10"
(254mm)
M965255 REV. 1.6
Page 6
3
HOW TO INSTALL AND CHANGE
BATTERY; Fig. 5
1. Remove the FAUCET COVER (1) by unthreading the
LEVER SCREW (2) and pulling off the LEVER
HANDLE (3). Unthread the FAUCET COVER SCREW
(4) at the back of the FAUCET. Pull FAUCET COVER
(1) up and off. See Fig. 2 in this section.
2. Remove BATTERY HOLDER (1) from FAUCET BODY (2).
3. Remove old battery from the BATTERY HOLDER (1).
4. Install NEW BATTERY (3) into the BATTERY
HOLDER (1). Replace BATTERY HOLDER (1) into the
FAUCET BODY (2).
5. Replace FAUCET COVER (1) and LEVER HANDLE
(3). I nstall LEVER HANDLE SCREW (2), FAUCET
COVER SCREW (4) and tighten. See Fig. 2 in this
section.
4
HOW TO REPLACE SENSOR;
Fig. 6, 7, & 8.
1. Remove the FAUCET COVER (1) by unthreading the
LEVER SCREW (2) and pulling off the LEVER
HANDLE (3). Unthread the FAUCET COVER SCREW
(4) at the back of the FAUCET. Pull FAUCET COVER
(1) up and off. See Fig. 2 in this section.
Fig. 5
1
2
3
Fig. 6
DISCONNECT
WIRE CONNECTIONS
2. Disconnect both WIRE CONNECTIONS. Fig. 6.
3. Untighten SENSOR SCREW (1) with a 2.5mm HEX
WRENCH. Remove SENSOR ASSEMBLY (2) from
FAUCET BODY (3). Remove SENSOR (2a) from
CARRIER (4) and replace with new SENSOR (2a).
Install SENSOR ASSEMBLY (2) into FAUCET BODY
(3). Tighten SENSOR SCREW (1). Fig. 7, 8.
4. Replace FAUCET COVER (1) and LEVER HANDLE (3).
Install LEVER HANDLE SCREW (2), FAUCET COVER
SCREW (4) and tighten. See Fig. 2 in this section.
Fig. 8
4
2a
Fig. 7
2.5mm HEX
WRENCH
2
3
1
5
M965255 REV. 1.6
Page 7
5
HOW TO CLEAN FILTER SCREEN
ON SOLENOID VALVE; Fig. 9 & 10
1. Remove the FAUCET COVER (1) by unthreading the
LEVER SCREW (2) and pulling off the LEVER
HANDLE (3). Unthread the FAUCET COVER SCREW
(4) at the back of the FAUCET. Pull FAUCET COVER
(1) up and off. See Fig. 2 in this section.
3. Unthread SOLENOID VALVE (2) from VALVE BODY
(3). Fig. 9.
4. Remove FILTER SCREEN (4) from base of SOLENOID VALVE (2). Rin se clea n and replac e. Fig. 10.
5. Thread SOLENOID VALVE (2) into VALVE BODY (3) and hand tighten. Reconnect WIRE CONNECTION (1).
Fig. 9.
Fig. 9
DISCONNECT
WIRE CONNECTION
1
Fig. 10
2
3
6. Replace FAUCET COVER (1) and LEVER HANDLE
(3). I nstall LEVER HANDLE SCREW (2), FAUCET
COVER SCREW (4) and tighten. See Fig. 2 in this
section.
6
HOW TO REPLACE DIVERTER
CARTRIDGE; Fig. 11 & 12
1. Remove the FAUCET COVER (1) by unthreading the
LEVER SCREW (2) and pulling off the LEVER
HANDLE (3). Unthread the FAUCET COVER SCREW
(4) at the back of the FAUCET. Pull FAUCET COVER
(1) up and off. See Fig. 2 in this section.
2. Pull out LIMITER STOP (1) from the VALVE STEM
(2). Unthread COLLAR NUT (3) from VALVE BODY (4).
Fig. 11.
3. Pull DIVERTER CARTRIDGE (5) out and replace
with new DIVERTER CARTRIDGE (5).
NOTE: Make sure the two ALIGMENT PINS (6) in the
base of the DIVERTER CARTRIDGE (5) are facing
upward.
4. Replace FAUCET COVER (1) and LEVER HANDLE
(3). I nstall LEVER HANDLE SCREW (2), FAUCET
COVER SCREW (4) and tighten. See Fig. 2 in this
section.
Fig. 11
Fig. 12
4
4
2
2
9
8
3
1
6
5
6
M965255 REV. 1.6
Page 8
7
CHANGE HOT LIMIT SETTING
FROM 95% TO 85%; Fig. 13
1. Remove the FAUCET COVER (1) by unthreading the
LEVER SCREW (2) and pulling off the LEVER
HANDLE (3). Unthread the FAUCET COVER SCREW
(4) at the back of the FAUCET. Pull FAUCET COVER
(1) up and off. See Fig. 2 in this section.
2
3
9
2. Replace LEVER HANDLE and rotate
counter-clockwise to its stop position (100% cold).
Remove HANDLE.
3. Pull out LIMITER STOP (1) from the VALVE STEM (2).
4. Rotate LIMITER STOP (1) 180 degrees and insert back onto VALVE STEM (2).
5. Replace FAUCET COVER (1) and LEVER HANDLE
(3). I nstall LEVER HANDLE SCREW (2), FAUCET
COVER SCREW (4) and tighten. See Fig. 2 in this
section.
GENERAL CLEANING; Fig. 14
8
1. For general cleaning use a damp, soft cloth to clean
the spout and the sensor.
2. For cleaning dirt use a soft cloth with diluted dish
washing detergent. Wipe the area using a wet cloth
and dry using a soft cloth.
CAUTION
Fig. 13
ROTATE 180˚
SLOT
8
SLOT
1
Do not scratch the sensor when cleaning.
Avoid using anything that may scratch the spout
surface. Never use polishing power, detergent or a
nylon scrub brush. They will damage the surface of the
spout or Sensor.
FAQ'S
Q: How will I know if battery needs to be replaced?
A: Valve does not open and sensor blinks 2 times interrupted by pause for up to 7 days.
Q: Why has the flow rate of the faucet reduced significantly?
A: Check and clean aerator and strainer.
Q: There is no flow out of faucet when I'm in the sensor range?
A: Check sensor. If sensor blinks 2 times interrupted by pause, replace battery, or call 1 800-442-1902.
Q: What is the normal operating pressure range?
A: Faucet will operate with supply pressures ranging from 20-80 psi.
Fig. 14
7
M965255 REV. 1.6
Page 9
SELECTRONIC
Proximity Integrated Faucet
with Above-Deck Mixing
PRODUCT NUMBERS
M964171-0070A
1.5 GPM AERATOR
M964172-0070A
0.5 GPM AERATOR
M954483-0070A
SOLENOID VALVE
M964173-007LOA
SENSOR
M900540-0020A
FAUCET COVER
(LESS MIXING)
M900541-0020A
FAUCET COVER
(FOR MIXING VALVE)
A912790-0070A
VALVE STEM O-RINGS
A923654-0070A
BATTERY 6VCR-P2
M950514-0070A
BATTERY HOLDER
M951479-0070A
DIVERTER CARTRIDGE
M911785-0070A
SPOUT O-RING
7055.105
7055.115
7056.105
7056.115
M964188-0070A
COLLAR NUT &
TEMPERATURE
LIMITER STOP
M964187-0020A
LEVER ASSEMBLY
7055.205
7055.215
7056.205
7056.215
M950317-0070A
AC POWER SUPPLY
705P400
ESCUTCHEON
M962146-0070A
MOUNTING KIT
M920013C-0070A
COLD SUPPLY HOSE
M920013H-0070A
HOT SUPPLY HOSE
M964333-0070A
HOSE ADAPTER
8
For toll-free information and answers to your questions, call: