American Standard 7055.115, 7056.105, 7055.105, 7056.205, 705.205 User Manual

...
Page 1
SELECTRONIC
Installation Instructions
®
Proximity Integrated Faucet
with Optional Above-Deck Mixing
®
Flexible Selectronic
Easy installation. All electronics in the spout; nothing below deck.
User adjustable above-deck mixing uses ceramic disc valve for dependability & long life
Mixing handle can be removed for one time temperature setting during installation
Available in DC (Battery) & AC versions
Platform with Universal Sensor
Product No.'s & Options
Specifications
How to Install
Maintenance
FAQ,s
Replacement Parts
M 9 6 52 5 5 RE V. 1.6
Installation Instructions
NOTE TO INSTALLER: Please give this manual to the customer after installation.
To l ea r n mo re a bo u t A me ri c an S ta nd ar d Fa u ce ts v i si t ou r we b si te at : www.americanstandard-us.com or U.S. customer's e-mail us at: faucetsupport@americanstandard.com
1
2
2-3
3-7
7-8
8
Certified to comply with ASME A112.18.1M
© 2012 American Standard
For Parts, Service, Warranty or other Assistance, please call
1-800-442-1902 (In Canada: 1-800-387-0369)
(In Toronto Area only: 1-905-3061093)
(In Toronto Area only: 1-905-3061093)
Page 2
Thank you for selecting American-Standard...the benchmark of fine quality for over 100 years. To ensure
In sta lla ti on Ins tru cti on s
In sta lla ti on Ins tru cti on s
that your installation proceeds smoothly--please read these instructions carefully before you begin.
UNPACKING
All American Standard Faucets Are Water Tested At Our Factory. Some Residual Water May Remain In The Faucet During Shipping.
1. R e mo v e t he f i tt i n g a nd l o os e i t e ms f r o m t h e c a r to n . T h e i l l u s t ra t i o n be l o w s h o w s t h e f it t in g a n d al l l o o s e i t e m s after they have been removed from the carton. Some items may be packaged partially assembled to other items.
1. Selectronic Spout Assembly
2. Mounting Kit
3. Battery (7055 Series)
3a. AC Power Supply (7056 Series)
4. 4" Deck plate (optional must be ordered separately)
5. Mixing Valve (optional must be ordered separately)
6. Key for vandal resistant aerator
7. Installation Instructions
8. Hose Adapters
Less Mixing With Above-Deck Mixing
PRODUCT No.s PRODUCT No.s
7055.105
7055.115
7056.105
7056.115
6
DO NOT REMOVE
PROTECTIVE FILM
FROM SENSOR EYE
UNTIL INSTALLATION
IS COMPLETE.
7055.205
7055.215
7056.205
7056.215
6
DO NOT REMOVE
PROTECTIVE FILM
FROM SENSOR EYE
UNTIL INSTALLATION
IS COMPLETE.
®
SELECTRONIC Proximity Integrated Faucet
with Optional Above-Deck Mixing
®
Platform with Universal Sensor
Flexible Selectronic
Easy installation. All electronics in the spout; nothing below deck.
User adjustable above-deck mixing uses ceramic disc valve for dependability & long life
Mixing handle can be removed for one time temperature setting during installation
Available in DC (Battery) & AC versions
Product No.'s & Options
Specifications
How to Install
Maintenance
FAQ,s
Replacement Parts
M965255 REV. 1.6
Installation Instructions
NOTE TO INSTALLER: Please give this manual to the customer after installation.
To lea r n m o r e a bo u t A me r i ca n St a nd a rd Fa u c et s v i s it ou r we b si t e a t : www.americanstandard-us.com or U.S. customer's e-mail us at: faucetsupport@americanstandard.com
For Parts, Service, Warranty or other Assistance, please call
1-800-442-1902 (In Canada: 1-800-387-0369)
(In Toronto Area only: 1-905-3061093)
(In Toronto Area only: 1-905-3061093)
705P400
Deck Plate Mixing ValveBase Product
605XTMV
3 3
7055.105
7055.205
7055.115
7055.215
7056.105
7056.205
7056.115
7056.215
3a
1
2
2-3
3-7
7-8
Certified to comply with ASME A112.18.1M
8
© 2012 American Standard
7
8
2
4
11
®
SELECTRONIC Proximity Integrated Faucet
with Optional Above-Deck Mixing
Flexible Selectronic
Easy installation. All electronics in the spout; nothing below deck.
User adjustable above-deck mixing uses ceramic disc valve for dependability & long life
Mixing handle can be removed for one time temperature setting during installation
Available in DC (Battery) & AC versions
Product No.'s & Options
Specifications
How to Install
Maintenance
FAQ,s
Replacement Parts
M965255 REV. 1.6
Installation Instructions
NOTE TO INSTALLER: Please give this manual to the customer after installation.
To lea r n m o r e a bo u t A me r i ca n St a nd a rd Fa u c et s v i s it ou r we b si t e a t : www.americanstandard-us.com or U.S. customer's e-mail us at: faucetsupport@americanstandard.com
For Parts, Service, Warranty or other Assistance, please call
1-800-442-1902 (In Canada: 1-800-387-0369)
705P400
®
Platform with Universal Sensor
(In Toronto Area only: 1-905-3061093)
(In Toronto Area only: 1-905-3061093)
7055.105
7055.205
7055.115
7055.215
7056.105
7056.205
7056.115
7056.215
3a
1
2
2-3
3-7
7-8
Certified to comply with ASME A112.18.1M
8
© 2012 American Standard
7
8
2
4
5
1
M965255 REV. 1.6
Page 3
Roughing-in Dimensions
Fig. 1
FINISHED WALL
OR BACKSPLASH
MIN. 1" CLEARANCE
3/8" COMPRESSION
CONNECTORS
191mm
(7-1/2)
140mm
(5-1/2)
38mm
(1-1/2 )
457mm
(18)
165mm
(6-1/2)
191mm
(7-1/2)
MOUNTING
66mm
( 2-5/8)
32mm (1-1/4)
SURFACE
GENERAL DESCRIPTION:
Electronic faucet with proximity operation. Vandal resistant solid brass construction single post mounting. Operates on DC (battery) or AC power. Inlets 3/8" compression, built-in checks, flexible stainless steel 18" reach inlet hoses for spout connection and In-line integral strainer for solenoid.
TOOLS REQUIRED; Fig. 2
1 Hex Wrench (Included) 2 Adjustable Wrench 3 Plumbers' Putty or Caulking
4 Phillips Screwdriver 5 Tape Measure
INSTALLATION
INSTALL SPOUT ASSEMBLY;
1
Fig. 1
1. Make sure O-RING SEAL (9) is installed.
2. Installation with ESCUTCHEON (1) (optional). Apply a
bead of putty to bottom edge of ESCUTCHEON with PUTTY PLATE (1). (Only if mounting surface is uneven).
3. Insert supply HOSES (2), SHANK (3) and POWER CORD (10) (if equipped) through hole in ESCUTCHEON with PUTTY
PLATE (1) and mounting surface. Follow mounting instructions below to secure faucet to mounting surface.
(Make sure PIN (7) is in back).
4. Installation less ESCUTCHEON (1). IMPORTANT: Do not use putty when installing faucet without escutcheon.
5. Assemble RUBBER WASHER (4), BRASS WASHER (5) and THREADED LOCKNUT (6) onto SHANK (3) from
underside of sink or mounting surface. Hand tighten LOCKNUT (6).
6. Use a screwdriver to tighten SCREWS (8) on LOCKNUT (6). Work your way around LOCKNUT (6), tightening the screws slightly each time until all are snug to ensure even pressure.
CONNECT POWER SUPPLY; Fig. 1a
2
CAUTION
(7056 series only)
1. Connect the sensor cable (1) to the POWER SUPPLY CABLE (2).
Turn off hot and cold water supplies before beginning
Fig. 2
3
Fig. 1
Fig. 1a
1
IMPORTANT: Do not
use putty when installing
faucet without escutcheon.
PUTTY
(If required)
1
2
3
10
2
4
9 3
2
4 5 6
1
8
5
7
(OPTIONAL)
MOUNTING SURFACE
TIGHTEN SPIN NUTS
10'
2. Code approved Electrical Outlet provided by others. (120V 50/60 Hz)
3. Plug AC POWER SUPPLY (3) into Outlet.
ELECTRICAL OUTLET (120V 50/60 Hz)
2
M965255 REV. 1.6
Page 4
MAKE WATER SUPPLY
Ins t a ll a t ion I ns t r u ct i o ns
3
CONNECTIONS; Fig. 2
1. Turn off hot and cold water supplies before
beginning.
Fig. 2
2. Connect HOSE ADAPTERS (3) to wall supplies (if
required). Connect FLEXIBLE SUPPLIES (1, 2) directly to HOSE ADAPTERS (3).
3. Connect left supply (Marked with a Red Stripe) to Hot and right supply (Marked with Blue Stripe) to Cold supply. Use adjustable wrench to tighten connections. Do not over tighten.
4. Faucet supplies are 18" long from faucet base.
Note; If additional supply length is required, installer must purchase those parts separately.
Important; If SUPPLY HOSES (1, 2) are too long, loop as illustrated to avoid kinking.
INSTALL OPTIONAL MIXING
4
VALVE; Fig. 3
For 7055.105/115 & 7056.105/115 Faucets.
Note; For complete detailed installation and operating instructions see installations instructions supplied with mixing valve. No. M968808
1
Fig. 3
No. M968808
3
HOT
COLD
SELECTRONIC™ Thermostatic Mixing Valve
605XTMV
Specications
Installation
Adjust Temperature
Service
Certified to comply with ASME A112.18.1M
© 2005 American Standard
M968808
Installation Instructions
NOTE TO INSTALLER: Please give this manual to the customer after installation.
To le a r n m or e ab o ut Am e r ic a n S t an d ar d F a uc e ts v is i t o u r w e bs i te at : www.us.amstd.com or U.S. customer's e-mail us at: faucetsupport@amstd.com
For Parts, Service, Warranty or other Assistance,
1-800-442-1902 (In Canada: 1-800-387-0369)
please call
Replacement Parts
(In Toronto Area only: 1-905-3061093)
(In Toronto Area only: 1-905-3061093)
2
SEAL WASHER (SUPPLIED)
1
2
3
3
4
MAINTENANCE
HAND WASH SENSOR OPERATION;
1
Fig. 1
REMOVE PROTECTIVE FILM FROM SENSOR EYE WHEN INSTALLATION IS COMPLETE.
When the Sensor detects a user, the water immediately starts to flow. Water flow will stop two seconds after user is out of sensor range. The off delay allows the user to comfortably move his hands without the flow cycling on to off. As a precaution, a safety timer will turn off the water, after the sensor has been blocked for 59 seconds. The water will stay off until the blockage is removed from the detection zone.
Detection Zone: 2" - 10" (50.8mm - 254mm) Default: Set at Factory 6" (152.4mm)
3
Fig. 1
DETECTION
ZONE
PROTECTIVE FILM
M965255 REV. 1.6
Page 5
2
HOW TO CHANGE SENSOR RANGE; (Factory set at 6") Fig. 2
1. Setting the Detection Zone (Distance):
Remove the FAUCET COVER (1) by unthreading the LEVER SCREW (2) and pulling off the LEVER HANDLE (3). Unthread the FAUCET COVER SCREW
(4) at the back of the FAUCET. Pull FAUCET COVER (1) up and off. Fig. 2.
Fig. 2
REMOVE
1
REPLACE
2. Disconnect the BLACK POWER SUPPLY CONNECTOR (1) and reconnect. Fig. 3.
3. While the SENSOR CONTROL LED (2) is blinking slowly, place your hand 1 - 2 in. (25.4-50.8mm) in front of the sensor. Fig. 4.
4. When the LED stops blinking and stays "ON", move your hand to the desired position and hold in place until the LED begins to blink again. Fig. 4a.
5. Once the SENSOR CONTROL LED (2) begins to blink again, remove your hand from the detection zone. When the flashing stops, the detection distance is set.
6. Replace FAUCET COVER (1) and LEVER HANDLE (3). I nstall LEVER HANDLE SCREW (2), FAUCET COVER SCREW (4) and tighten. Fig. 2.
Fig. 3
3
2
4
1
Fig. 4 Fig. 4a
1"-2"
(25.4mm-
50.8mm)
2
BLINKING LED
4
2
BLINKING LED
UP TO 10"
(254mm)
M965255 REV. 1.6
Page 6
3
HOW TO INSTALL AND CHANGE BATTERY; Fig. 5
1. Remove the FAUCET COVER (1) by unthreading the
LEVER SCREW (2) and pulling off the LEVER HANDLE (3). Unthread the FAUCET COVER SCREW
(4) at the back of the FAUCET. Pull FAUCET COVER (1) up and off. See Fig. 2 in this section.
2. Remove BATTERY HOLDER (1) from FAUCET BODY (2).
3. Remove old battery from the BATTERY HOLDER (1).
4. Install NEW BATTERY (3) into the BATTERY
HOLDER (1). Replace BATTERY HOLDER (1) into the FAUCET BODY (2).
5. Replace FAUCET COVER (1) and LEVER HANDLE (3). I nstall LEVER HANDLE SCREW (2), FAUCET
COVER SCREW (4) and tighten. See Fig. 2 in this section.
4
HOW TO REPLACE SENSOR; Fig. 6, 7, & 8.
1. Remove the FAUCET COVER (1) by unthreading the
LEVER SCREW (2) and pulling off the LEVER HANDLE (3). Unthread the FAUCET COVER SCREW
(4) at the back of the FAUCET. Pull FAUCET COVER (1) up and off. See Fig. 2 in this section.
Fig. 5
1
2
3
Fig. 6
DISCONNECT
WIRE CONNECTIONS
2. Disconnect both WIRE CONNECTIONS. Fig. 6.
3. Untighten SENSOR SCREW (1) with a 2.5mm HEX
WRENCH. Remove SENSOR ASSEMBLY (2) from FAUCET BODY (3). Remove SENSOR (2a) from CARRIER (4) and replace with new SENSOR (2a). Install SENSOR ASSEMBLY (2) into FAUCET BODY
(3). Tighten SENSOR SCREW (1). Fig. 7, 8.
4. Replace FAUCET COVER (1) and LEVER HANDLE (3).
Install LEVER HANDLE SCREW (2), FAUCET COVER SCREW (4) and tighten. See Fig. 2 in this section.
Fig. 8
4
2a
Fig. 7
2.5mm HEX WRENCH
2
3
1
5
M965255 REV. 1.6
Page 7
5
HOW TO CLEAN FILTER SCREEN ON SOLENOID VALVE; Fig. 9 & 10
1. Remove the FAUCET COVER (1) by unthreading the
LEVER SCREW (2) and pulling off the LEVER HANDLE (3). Unthread the FAUCET COVER SCREW
(4) at the back of the FAUCET. Pull FAUCET COVER (1) up and off. See Fig. 2 in this section.
2. Disconnect WIRE CONNECTION (1) to SOLENOID VALVE (2). Fig. 9.
3. Unthread SOLENOID VALVE (2) from VALVE BODY (3). Fig. 9.
4. Remove FILTER SCREEN (4) from base of SOLENOID VALVE (2). Rin se clea n and replac e. Fig. 10.
5. Thread SOLENOID VALVE (2) into VALVE BODY (3) and hand tighten. Reconnect WIRE CONNECTION (1). Fig. 9.
Fig. 9
DISCONNECT
WIRE CONNECTION
1
Fig. 10
2
3
6. Replace FAUCET COVER (1) and LEVER HANDLE (3). I nstall LEVER HANDLE SCREW (2), FAUCET
COVER SCREW (4) and tighten. See Fig. 2 in this section.
6
HOW TO REPLACE DIVERTER CARTRIDGE; Fig. 11 & 12
1. Remove the FAUCET COVER (1) by unthreading the
LEVER SCREW (2) and pulling off the LEVER HANDLE (3). Unthread the FAUCET COVER SCREW
(4) at the back of the FAUCET. Pull FAUCET COVER (1) up and off. See Fig. 2 in this section.
2. Pull out LIMITER STOP (1) from the VALVE STEM (2). Unthread COLLAR NUT (3) from VALVE BODY (4). Fig. 11.
3. Pull DIVERTER CARTRIDGE (5) out and replace
with new DIVERTER CARTRIDGE (5). NOTE: Make sure the two ALIGMENT PINS (6) in the base of the DIVERTER CARTRIDGE (5) are facing upward.
4. Replace FAUCET COVER (1) and LEVER HANDLE (3). I nstall LEVER HANDLE SCREW (2), FAUCET
COVER SCREW (4) and tighten. See Fig. 2 in this section.
Fig. 11
Fig. 12
4
4
2
2
9
8
3
1
6
5
6
M965255 REV. 1.6
Page 8
7
CHANGE HOT LIMIT SETTING FROM 95% TO 85%; Fig. 13
1. Remove the FAUCET COVER (1) by unthreading the
LEVER SCREW (2) and pulling off the LEVER HANDLE (3). Unthread the FAUCET COVER SCREW
(4) at the back of the FAUCET. Pull FAUCET COVER (1) up and off. See Fig. 2 in this section.
2
3
9
2. Replace LEVER HANDLE and rotate
counter-clockwise to its stop position (100% cold). Remove HANDLE.
3. Pull out LIMITER STOP (1) from the VALVE STEM (2).
4. Rotate LIMITER STOP (1) 180 degrees and insert back onto VALVE STEM (2).
5. Replace FAUCET COVER (1) and LEVER HANDLE (3). I nstall LEVER HANDLE SCREW (2), FAUCET
COVER SCREW (4) and tighten. See Fig. 2 in this section.
GENERAL CLEANING; Fig. 14
8
1. For general cleaning use a damp, soft cloth to clean
the spout and the sensor.
2. For cleaning dirt use a soft cloth with diluted dish washing detergent. Wipe the area using a wet cloth and dry using a soft cloth.
CAUTION
Fig. 13
ROTATE 180˚
SLOT
8
SLOT
1
Do not scratch the sensor when cleaning.
Avoid using anything that may scratch the spout surface. Never use polishing power, detergent or a
nylon scrub brush. They will damage the surface of the spout or Sensor.
FAQ'S
Q: How will I know if battery needs to be replaced? A: Valve does not open and sensor blinks 2 times interrupted by pause for up to 7 days.
Q: Why has the flow rate of the faucet reduced significantly? A: Check and clean aerator and strainer.
Q: There is no flow out of faucet when I'm in the sensor range? A: Check sensor. If sensor blinks 2 times interrupted by pause, replace battery, or call 1 800-442-1902.
Q: What is the normal operating pressure range? A: Faucet will operate with supply pressures ranging from 20-80 psi.
Fig. 14
7
M965255 REV. 1.6
Page 9
SELECTRONIC
Proximity Integrated Faucet
with Above-Deck Mixing
PRODUCT NUMBERS
M964171-0070A
1.5 GPM AERATOR
M964172-0070A
0.5 GPM AERATOR
M954483-0070A
SOLENOID VALVE
M964173-007LOA
SENSOR
M900540-0020A
FAUCET COVER (LESS MIXING)
M900541-0020A
FAUCET COVER (FOR MIXING VALVE)
A912790-0070A
VALVE STEM O-RINGS
A923654-0070A
BATTERY 6VCR-P2
M950514-0070A
BATTERY HOLDER
M951479-0070A
DIVERTER CARTRIDGE
M911785-0070A
SPOUT O-RING
7055.105
7055.115
7056.105
7056.115
M964188-0070A
COLLAR NUT & TEMPERATURE LIMITER STOP
M964187-0020A
LEVER ASSEMBLY
7055.205
7055.215
7056.205
7056.215
M950317-0070A
AC POWER SUPPLY
705P400
ESCUTCHEON
M962146-0070A
MOUNTING KIT
M920013C-0070A
COLD SUPPLY HOSE
M920013H-0070A
HOT SUPPLY HOSE
M964333-0070A
HOSE ADAPTER
8
For toll-free information and answers to your questions, call:
IN CANADA 1-800-387-0369 (TORONTO 1-905-306-1093)
Product names listed herein are trademarks of American Standard Inc. © American Standard Inc. 2012
HOT LINE FOR HELP
1 (800) 442-1902
Weekdays 8:00 a.m. to 8:00 p.m. EST
Weekdays 8:00 a.m. to 7:00 p.m. EST
M965255 REV. 1.6
Loading...