HERITAGE SERIES
SINGLE BUILT-IN
WALL SUPPLY VALVES
Installation
Instructions
7000 SERIES
7001 SERIES
7006 SERIES
7007 SERIES
Thank you for selecting American-Standard...the benchmark
of fine quality for over 100 years.
To ensure that your installation proceeds smoothly--please
read these instructions carefully before you begin.
7000 SERIES
STRAIGHT VALVE
W/LOOSE KEY
FIXATION
PLATE
MOUNTING
SCREWS
ESCUTCHEON
7001 SERIES
STRAIGHT VALVE
VALVE
O-RING
COVER
7006 SERIES
BYPASS VALVE, "HOT"
VALVE
SCREW
Certified to comply with ANSI A112.18.1M
U.S. Patent No. 5,819,789
34803N
7007 SERIES
BYPASS VALVE, "COLD"
VALVE
BODY
UNION
SWIVEL
Printed in Mexico
A
X
M
W
A
L
L
PLASTER
GUARD
COUPLING
ROUGHING-IN DIMENSIONS
+
2-3/8 1/2
-
BY-PASS OUTLET THREADED
1/2'' N.P.T. INSIDE
CROSS
BRACE
2
UNION INLET
1/2"-14 N.P.T.
BY-PASS OUTLET THREADED
1/2'' N.P.T. INSIDE
NUT
2.1 DIA.
FINISHED
WALL
1-1/8
1-1/8
1
CAUTION
ROUGHING-IN FITTING
Prepare water supplies per "Roughing-in Dimensions."
Slip COUPLING NUT over supply pipe and screw UNION SWIVEL
to pipe.
For Sweat Connection: Slip COUPLING NUT over 5/8'' O.D.supply
tube and solder tube into UNION SWIVEL or female inlet of stop.
Install VALVE at indicated height and depth. Note MAX WALL
marking on PLASTER GUARD for the finished wall.
Connect HOT water supply to left VALVE inlet and COLD water
supply to right VALVE inlet. Tighten both COUPLING NUTS firmly.
Add cross braces to wall structure and secure piping.
Secure VALVE BODY to cross brass of wall structure.
Cap roughing-in nipples, open supply lines and check for leaks.
Remove PLASTER GUARD. (Do not discard.) Open valves,
and check for leaks.
Close both valves, turn off water supplies, and replace
PLASTER GUARDS.
Finish wall construction. NOTE: Apply wall finish as close as
possible to the PLASTER GUARD.
Turn off hot and cold water
supplies before beginning.
"MAX WALL"
PLASTER
GUARD
FIXATION
PLATE
CROSS
BRACE
PIPE
STRAP
THREADED
A
X
M
W
A
L
L
TABS
VALVE
VALVE
CARTRIDGE
UNION
SWIVEL
FINISHING INSTALLATION
2
Remove roughing-in nipples.
Remove SCREWS holding PLASTER GUARDS and remove
PLASTER GUARD.
Slip VALVE COVER over VALVE CARTRIDGE. Push VALVE
COVER to complete stop.
Place O-RING in FIXATION PLATE as shown.
Place FIXATION PLATE over VALVE ASSEMBLY. Line up
holes in FIXATION PLATE with THREADED TABS on VALVE.
Pass MOUNTING SCREWS (2) through FIXATION PLATE and
engage THREADED TABS. Tighten SCREWS securely.
Place ESCUTCHEON over FIXATION PLATE and push evenly
for a snap fit.
Assemble handle per separate "Handle Installation Instructions."
TEST INSTALLED FAUCET
3
Turn HANDLES into OFF position.
Turn on water supplies, open stops and check all connections
for leaks.
SERVICE
4
To change direction of handle rotation,
proceed as follows:
Turn valve to OFF position.
Remove INSERT and HANDLE SCREW.
Slip HANDLE with ADAPTER off.
Remove SPRING CLIP.
Lift STOP WASHER, turn 90° and replace.
Replace SPRING CLIP.
Replace ADAPTER, HANDLE, SCREW, and INSERT.
If spout drips, operate handles several times from
OFF to ON position. Do not force - handles turn only 90°.
For toll-free information and answers to your questions, call:
Weekdays 8:00 a.m. to 7:00 p.m. Eastern Time
Saturdays 8:00 a.m. to 4:00 p.m. Eastern Time
IN CANADA 1-800-387-0369 (TORONTO 1-416-536-5609)
HOTLINE FOR HELP
1 (800) 442-1902
SPRING
CLIP
STOP
WASHER
VALVE
COVER
O-RING
COUPLING
NUT
MOUNTING
SCREWS
SUPPLY
ESCUTCHEON
Operate HANDLE to flush water lines thoroughly.
Turn handles OFF.
To access CARTRIDGE:
Remove HANDLE and adapter.
Use thin blade screwdriver to remove
ESCUTCHEON from FIXATION PLATE.
Unscrew MOUNTING SCREWS and
pull FIXATION PLATE from wall.
Pull off VALVE COVER.
Plastic SCREEN in CARTRIDGE may accumulate
dirt causing reduced water flow. To clean, first
turn off hot and cold water supplies, then:
Remove INSERT and HANDLE SCREW.
Slip HANDLE with ADAPTER off.
Unscrew CARTRIDGE with wrench.
Thoroughly rinse plastic SCREEN at
base of CARTRIDGE.
Replace CARTRIDGE until flange is
tight against valve body.
Turn valves OFF.
Replace ADAPTER, HANDLE, SCREW,
and INSERT.
Product names listed herein are trademarks of American Standard Inc.
C
American Standard Inc. 1999
CARTRIDGE
SCREEN
PIPE
34803N