American Standard 2646, 656, 3600 User Manual

INSTALLATION
For These Two-Piece Toilets:
INSTRUCTIONS
Ravenna 2642/2648/2646 Cadet 2656/2798/2898/2998/3600 Reminiscence 2311/2011
Thank you for selecting American Standard - the benchmark of fine quality for over 100 years. To ensure this product is installed properly, please read these instructions carefully before you begin. (Certain installations may require professional help.) Also be sure your installation conforms to local codes.
!
CAUTION: PRODUCT IS FRAGILE. TO AVOID BREAKAGE AND POSSIBLE INJURY HANDLE WITH CARE!
NOTE:
RECOMMENDED TOOLS AND MATERIALS
Putty Knife Regular Screwdriver Adjustable Wrench Sealant Tape Measure Hacksaw Wax Ring/Gasket Flexible Supply Tube Closet Bolts Carpenters Level
1 REMOVE OLD TOILET
a. Close toilet supply valve and flush tank completely. Towel or sponge remaining water from tank and bowl. b. Disconnect and remove supply line. NOTE: c. Remove old mounting hardware, remove toilet and plug floor waste opening to prevent escaping sewer gases. d. Remove closet bolts from flange and clean away old wax, putty, etc. from base area.
Pictures may not exactly define contour of china and components.
If replacing valve, first shut off main water supply!
NOTE:
FINISHED WALL
Mounting surface must be clean and level before new toilet is installed!
ROUGHING-IN DIMENSIONS:
NOTE:
Distance from wall to closet flange centerline must
be as listed below:
For 4110 Tanks: A = 10" (254mm) For 4114 Tanks: A = 14" (356mm) For all other Tanks: A = 12" (305mm)
32
CLOSET FLANGE
A
SUPPLY
AS
REQ'D.
FINISHED
A
SEALANT
INSTALL WAX SEAL
Invert toilet on floor (cushion to prevent damage), and install wax ring evenly around waste flange (horn), with tapered end of ring facing toilet. Apply a thin bead of sealant around toilet base.
FLOOR
WAX RING
CLOSET BOLTS
INSTALL CLOSET BOLTS
Install closet bolts in flange channel, turn 90°, and slide into place 6" (152 mm) apart and parallel to wall.
54
NUT
TAPERED WASHER
CLOSET
BOLT
FLANGE
POSITION TOILET ON FLANGE
a. Unplug floor waste opening and install toilet on closet flange so bolts project
through mounting holes.
b. Loosely install retainer washers and nuts. Side of washers marked "THIS
SIDE UP"
must
face up!
SAVE FOR FUTURE USE
Product names listed herein are trademarks of American Standard Inc. © American Standard Inc. 2003
Saniwares
730504-100 REV. B
6
7a 7b
BOLT CAP
CLOSET FLANGE
CLOSET BOLT
WASHER
NUT
INSTALL TOILET
a. Position toilet squarely to wall and, with a rocking
motion, press bowl down fully on wax ring and flange. Alternately tighten nuts until toilet is firmly seated on floor.
!
CAUTION:
DO NOT OVERTIGHTEN NUTS
OR BASE MAY BE DAMAGED!
b. Install caps on washers. (If necessary, cut bolt height
to size before installing caps.)
c. Smooth off the bead of sealant around base. Remove
excess sealant.
For Tanks/Bowls using Speed Connect System (Tank mounting bolts pre-installed).
TANK MTG. BOLTS PRE­INSTALLED
WASHER
NUT
INSTALL TANK
a. Install large rubber gasket over
threaded outlet on bottom of tank and lower tank onto bowl so that tapered end of gasket fits evenly into bowl water inlet opening, and tank mounting bolts go through mounting holes. Secure with metal washers and nuts.
b. With tank parallel to wall, alternately
tighten nuts until tank is snugged down evenly against bowl surface.
!
CAUTION:
DO NOT OVERTIGHTEN NUTS MORE
THAN REQUIRED FOR A SNUG FIT!
RUBBER GASKET
For all other Tanks/Bowls
RUBBER WASHER
TANK MTG.
BOLTS
WASHER
NUT
INSTALL TANK
a. Install large rubber gasket over
threaded outlet on bottom of tank and lower tank onto bowl so that tapered end of gasket fits evenly into bowl water inlet opening.
b. Insert tank mounting bolts and
rubber washers from inside tank, through mounting holes, and secure with metal washers and nuts.
c. With tank parallel to wall, alternately
tighten nuts until tank is snugged down evenly against bowl surface.
!
CAUTION:
DO NOT OVERTIGHTEN NUTS MORE
THAN REQUIRED FOR A SNUG FIT!
RUBBER GASKET
8
INSTALL TOILET SEAT Install toilet seat in accordance with manufacturer's directions.
9a 9b
Before continuing, determine the type of water supply connecation you have from the chart below and use the appropriate assembly parts required to properly reconnect the water supply. DO NOT use plumber's putty to seal these fittings.
METAL/COPPER
FLARED TUBING
CONE WASHER
COUPLING NUT
WATER SHUT-OFF
These parts must be used as illustrated to insure water-tight connection. Use of existing coupling nut may result in water leakage. Water supply tube or pipe must extend at least 1/2" inside threaded shank of valve (does not apply to flanged tubing).
CAUTION: DO NOT USE CONE WASHER WITH PLASTIC SUPPLY LINE.
METAL FLANGED
TUBING
Use existing coupling nut and washer.
EXISTING WASHER
EXISTING COUPLING NUT
WATER SHUT-OFF
METAL SPIRAL
TUBING
Use existing spiral cone washer. Fluidmaster cone washer may not seal completely on spiral type supply line.
EXISTING CONE WASHER
COUPLING NUT
WATER SHUT-OFF
VINYL/BRAIDED
CONNECTOR
WATER SHUT-OFF
Captive cone washers already included. No additional washers needed.
LOCK NUTLOCK NUT LOCK NUT LOCK NUT COUPLING
NUT
CAUTION: Overtightening of LOCK NUT or COUPLING NUT could result in breakage and potential flooding.
With correct washers in place (see Step 9a), tighten COUPLING NUT 1/4 turn beyond hand tight. DO NOT OVERTIGHTEN.