American Standard 605X.102, 605X.163, 605X.104, 605X.164, 605X.105 Installation Manual

...
SELECTRONIC
®
Proximity Faucets
Cast Spout and
Gooseneck Spout
MODEL NUMBERS
605X.102 605X.163
CAUTION: Use only American Standard
supplied cable sets. Using non-AS supplied cables, or cutting, splicing or modifying any components will void the warranty.
605X.104 605X.164
605X.105 605X.165
1
2-3
2-3
4-6
4-6
7-8
7-8
9-10
9-10
11
11
1
2
2
Product No.'s & Options
Specifications
Faucet Installation
Electrical Installation
Start-up / Maintenance
FAQ’s / Troubleshooting
Certified to comply with ASME A112.18.1
© 2015 American Standard
Installation Instructions
NOTE TO INSTALLER: Please give this manual to the customer after installation.NOTE TO INSTALLER: Please give this manual to the customer after installation.
Parts
To learn more about American Standard Selectronic® Products visit our website at: www.americanstandard-us.com or e-mail us at: CRTTEAM@americanstandard.com
For Parts, Service, Warranty or other Assistance,
please call (844) CRT-TEAM / (844) 278-8326 (In Canada: 1-800-387-0369)
(In Toronto Area only: 1-905-306-1093)
M965650 Rev. 1.3 (8/15)
Thank you for selecting American-Standard...the benchmark of fine quality for over 100 years. To ensure
Ins tal lati on I nstr uct ions
that your installation proceeds smoothly--please read these instructions carefully before you begin.
UNPACKING
The illustration below shows the fitting and all loose items after they have been removed from the carton. Some items may be packaged partially assembled to other items.
1. Installation Instructions
2. Cast Spout Assembly 2a. Gooseneck Spout Assembly
3. Mounting Kit
4. Control Box
5. Supply Hose 6a. DC Long Life Power Pack 6b. DC Standard Battery 6c. AC Plug-In Power Supply
How to order the Selectronic Product
1. Choose Power Supply
2. Choose Desired Spout
605X.10X
All American Standard Faucets Are Water Tested At Our Factory. Some Residual Water May Remain In The Faucet During Shipping.
6d. AC Hard-Wire Power Transfomer
7. Y-Adapter
8. 27" Extension Cable
9. 10 ft. Extension
10. 4" Deck plate (optional, must be ordered separately)
11. 8" Deck plate (optional, must be ordered separately)
12. Mixing Valve (optional, must be ordered separately)
13. Control Box Cover Screws
DC Long Life
Power Pack
6053.Series
DC Standard
Battery
6055.Series
AC Plug-in
6056.Series
AC Hardwire
6059.Series
AC Multi
6057.Series
• Single Hole Sink
• Single Inlet
Base Product Deck Plate (optional) Mixing Valve (optional)
• 1 and 3 Hole Sinks
• Single Inlet
• 1 and 3 Hole Sinks
• Hot and Cold Inlets
2
Base Product
3
4
5
13
DO NOT REMOVE PROTECTIVE FILM FROM SENSOR EYE UNTIL INSTALLATION IS COMPLETE.
2a
SELECTRONIC Proximity Faucets
Cast Spout and
Goose Neck Spout
1
Certified to comply with ASME A112.18.1
© 2015 American Standard
Installation Instructions
NOTE TO INSTALLER: Please give this manual to the customer after installation.NOTE TO INSTALLER: Please give this manual to the customer after installation.
To learn more about American Standard Selectronic® Products visit our website at: www.americanstandard-us.com or e-mail us at: CRTTEAM@americanstandard.com
For Parts, Service, Warranty or other Assistance,
please call (844) CRT-TEAM / (844) 278-8326 (In Canada: 1-800-387-0369)
605X.16X
DO NOT REMOVE PROTECTIVE FILM FROM SENSOR EYE UNTIL INSTALLATION IS COMPLETE.
MODEL NUMBERS
®
605X.102
605X.104
605X.163
605X.164
CAUTION: Use only American Standard
supplied cable sets. Using non-AS supplied cables, or cutting, splicing or modifying any components will void the warranty.
Product No.'s & Options
Specifications
Faucet Installation
Electrical Installation
Start-up / Maintenance
FAQ’s / Troubleshooting
Parts
(In Toronto Area only: 1-905-306-1093)
6d
7
8
6a
6b
6c
7
9
88 8
605X.105 605X.165
1 1
2 2
2-3 2-3
4-6 4-6
7-8 7-8
9-10 9-10
11
11
8
Deck Plate
605P400
7
Mixing Valve
605P800
605XTMV
12
11
1
M965650 Rev. 1.3 (8/15)
Fig. 1
Roughing-in Dimensions
141mm (5-1/2)
131mm
(5-1/8)
MOUNTING SURFACE
6-1/8"
(155mm)
7"
(179mm)
11-1/8"
(284mm)
GENERAL DESCRIPTION:
Electronic faucet with proximity operation. Vandal resistant solid brass construction single post mounting. Operates on DC (battery/power pack) or AC permanent power (plug-in/hardwire). In-line strainer for solenoid is integral. Single inlet 3/8 compression, built-in check valves, and flexible stainless steel 16-1/4" reach inlet hose for spout connection.
Note: All plumbing and electrical wiring must be installed in accordance with applicable codes, regulations and standards.
81mm
(3-3/16)
381mm
(15)
3/8" COMP.
49mm
(2)
114mm (4-1/2)
500mm
(20")
32mm (1-1/4)
125mm
(4-7/8)
1524mm
(60)
TOOLS REQUIRED; Fig. 2
1 Slip Joint Pliers 2 Adjustable Wrench 3 Plumbers' Putty or Caulking 4 Phillips Screwdriver 5 Flat Blade Screwdriver 6 Electric Drill & 1/4" Drill Bit 7 Tape Measure
49mm
(2)
381mm
(15)
Fig. 2
3
CAUTION: Use only American Standard
supplied cable sets. Using non-AS supplied cables, or cutting, splicing or modifying any components will void the warranty.
RECOMENDED ELECTRICAL BOX OR EQUIVALENT BY OTHERS
4" (102mm) SQ. X 3-1/2" (89mm) DEEP ELECTRICAL BOX
Hubbel-RACO #256 OR EQUAL (BY OTHERS).
HARD-WIRED AND MULTI AC 10’ MAX. CABLE LENGTH
1
7
4
10'
2
6
5
INSTALLATION
INSTALL SPOUT ASSEMBLY;
1
Fig. 1
CAUTION
1. (Optional) Assemble DECK PLATE (1) and PUTTY PLATE (2) to FAUCET BODY (3) with SCREW (4).
2. Connect the two 27" EXTENSION CABLES (5) to
the Faucet Sensor Cables.
3. Insert 27" EXTENSION CABLES (5) , FLEX HOSE (6) and SPOUT SHANK (7) through center hole of mounting surface.
4. Assemble "C" WASHER (8) and LOCKNUT (10) onto threads of SPOUT SHANK (7) from underside of mounting surface.
5. Align FAUCET (3) and tighten LOCKNUT (10). If using DECK PLATE (1) hand tighten DECK PLATE SPIN NUTS (11) to secure FAUCET (3) to mounting surface. Fig. 1b.
Turn off hot and cold water supplies before beginning
Fig. 1
122
4
3
1
SENSOR CABLES
5
10
7
11
5
7
8
6
2
M965650 Rev. 1.3 (8/15)
MOUNT CONTROL BOX; Fig. 2
2
1. Determine location of CONTROL BOX (1). It must be
located with-in the 14" (356mm) by 21" (533mm) shaded area shown in Figure 2 in order for electrical connections from the spout assembly to be made.
NOTE: CONTROL BOX SUPPLY HOSE is 20". Distance between wall supply and CONTROL BOX (1) must be taken into consideration.
2. Remove tape from CONTROL BOX COVER (2) and
pull off COVER (2). Hold the CONTROL BOX (1) in desired location and mark the four mounting hole locations as shown.
NOTE: Find plastic bag containing 4 M5X16 screws to be used for securing the CONTROL BOX COVER (1) when installation is complete.
NOTE: For AC installation, make power supply connection before mounting CONTROL BOX (1) to wall.
3. It is recommended that the CONTROL BOX (1) be secured
to a wall stud or cross brace within the wall using the SCREWS (3) supplied. If the CONTROL BOX (1) is to be installed on tile or plaster walls, the ANCHORS (4) and SCREWS (3) should be used.
Fig. 2
LAVATORY RIM OR MOUNTING SURFACE
14"
SUPPLIES
WASTE
MOUNTING HOLES
(500mm)
21"
(mm)
(356mm)
1
1524mm
20"
(60)
(76mm)
3"
ENCLOSURE
MOUNTING
HOLES
2-3/4"
(71mm)
3-3/4"
(96mm)
3
1
4
2
1
NOTE: If using Mixing Valve (optional) See Sheet #M968808 for installation instructions.
3
CONNECT SPOUT HOSE TO CONTROL BOX; Fig. 3
1. Connect SUPPLY NUT (1) from spout hose to nipple on
top of CONTROL BOX (2). Tighten with adjustable wrench to make a water tight connection. Fig. 3.
CONNECT WATER SUPPLY TO
4
CONTROL BOX AND WALL SUPPLY; Fig. 4, 4a
NOTE; If using the optional Mixing Valve See Sheet #M968808 for installation instructions.
1. Insert FIBER WASHER (4) into SUPPLY NUT (1) on CONTROL BOX (2).
2. Connect FLEXIBLE SUPPLY HOSE (3) to SUPPLY
NUT (1) on CONTROL BOX (2). Tighten to make a water tight connection. Use two wrenches to tighten if necessary. Fig. 4.
3. Connect FLEXIBLE SUPPLY HOSE (3) directly to wall supply. Connection on FLEXIBLE SUPPLY HOSE (3) is 3/8" compression. Use adjustable wrench to tighten connection. Do not over tighten. Fig. 4a.
Note: FLEXIBLE SUPPLY HOSE (3) measures 20" from the bottom of the CONTROL BOX (2) base. If additional supply length is required, installer must purchase parts separately.
Important: If FLEXIBLE SUPPLY HOSE (3) is too long, loop to avoid kinking.
3
Fig. 3
Fig. 4
Fig. 4a
1
2
2
1
COLD WATER OR
TEMPERED
WALL SUPPLY
4
3
3
M965650 Rev. 1.3 (8/15)