American Standard 6047SM111, 6047SM121, 6047SM161 User Manual

PRODUCT FEATURES:
Hands-free infrared sensor-operated gear actuator with chrome plated metal housing
Angled Sensor delivers reliable ush even with toilet seat in raised position
Self-cleaning brass piston with integral wiper spring prevents clogging and valve run-on
Electronic courtesy ush button
Optional Sanitary Flush: Automatic ush after
24 hours of non-use
Object Detection Indicator: LED blinks when user or object is detected
User in View Indicator: Green LED ashes 3 times after user is detected for 5 seconds
Low Battery Indicator: Yellow LED ashes when batteries need to be replaced
Easy Battery Replacement: Water does not need to be shut off to change batteries
Chloramine-resistant EPDM seals
No external volume adjustment
MANUAL TOILET FLUSH VALVE
WITH SIDE-MOUNT OPERATOR
MODEL NUMBER:
6 0 47 S M.111 Manual Flush Valve with Side-Mount
Operator for 1-1/2" ushometer bowl, 1.1 gpf
6 0 47 S M .121 Manual Flush Valve with Side-Mount
Operator for 1-1/2" ushometer bowl, 1.28 gpf
6047SM.161 Manual Flush Valve with Side-Mount
Operator for 1-1/2" ushometer bowl, 1.6 gpf
25 psi (owing)-80 psi (static)
FLOW REQUIREMENT:
25 gpm (94.6 L/min.)
BAT TERY LIFE:
100,000 ushes (3+ years @ 3,000 ushes per month) (4) “C” alkaline batteries included
ADJUSTABLE RANGE:
8" to 48" (32" default)
User In View Indicator (Green
LED ashes 3 times after user is
detected for 5 seconds)
Low Battery
(Yellow LED)
Object Detection
Courtesy Flush Button
TYPICAL WATER CLOSET INSTALLATION:
AFWALL™ TOILET SHOWN
FINISHED WALL
ON BACK
SUPPLY
DN 25 mm
(1" I.P.S.)
121 mm, +/-13 mm (4-3/4")(+/-1/2")
343 mm
(13-1/2")
295 mm (11-1/2")
-C-L-
73 tmm (2-7/8")
CRITICAL LEVEL
SEE ROUGH-IN
Can be installed left or right handed
Installation tools included
FINISHED
FLOOR
RECOMMENDED SPECIFICATION:
Toilet flush valve includes sensor-operated gear actuator with metal casing. Brass valve body and cover with chrome finish. Features self-cleaning brass piston valve with integral wiper spring in bypass orifice to prevent clogging. Valve closes and does not need to be reset after loss of water pressure. Includes sweat solder kit with wall flange and cover tube. Vacuum breaker and angle stop with vandal resistant cap and back-flow protection included.
© 2017 AS America Inc.
(6/17 )
MANUAL TOILET FLUSH VALVE
*Note: The Critical Line (-C-L-) on Vacuum Breaker must typically be 6
" (152mm) minimum above fixture.
Consult Codes for details.
FOR 1-1/2" TOP SPUD FIXTURES
-C-L-
*CRITICAL LEVEL
SUPPLY DN 25 mm (1" I.P.S.)
295 mm (11-1/2")
ROUGH-IN
DIMENSION
FINISHED WALL
135 mm
(13-1/2")
38 mm-127 mm
(1-1/2-5")
152 mm
(6")
(Min.)
147 mm
(5-13/16")
253 mm
(9-15/16")
Roughing-in Dimensions
108 mm-133 mm (4-1/4" to 5-1/4")
WITH SIDE-MOUNT OPERATOR
LISTINGS:
• ASSE 1037
• ANSI/ASME A112.19.2
• ADA Compliant
Roughing-in Dimensions
147 mm
(5-13/16")
-C-L-
253 mm
(9-15/16")
152 mm
(6")
(Min.)
108 mm-133 mm (4-1/4" to 5-1/4")
SUPPLY DN 25 mm (1" I.P.S.)
*CRITICAL LEVEL
INCLUDES:
1" I.P.S. angle stop with back-ow prevention and vandal-resistant cap
Sweat solder kit including cover tube and wall ange
High back pressure vacuum breaker with down tube
Spud coupling & ange for 1-1/2" top spud
FINISHED WALL
38 mm-127 mm
(1-1/2-5")
135 mm
(13-1/2")
ROUGH-IN
DIMENSION
295 mm (11-1/2")
*Note: The Critical Line (-C-L-) on Vacuum Breaker must typically be 6
Consult Codes for details.
MEETS THE AMERICANS WITH DISABILITIES ACT GUIDELINES AND ANSI A117.1 REQUIREMENTS FOR ACCESSIBLE AND USABLE BUILDING FACILITIES-CHECK LOCAL CODES
" (152mm) minimum above fixture.
FOR 1-1/2" TOP SPUD FIXTURES
Right or Left Hand Installation
© 2017 AS America Inc.
(6/17 )