MANUAL TOILET
FLU SH VALVE
1.6 GPF
MODEL NUMBER:
❑ 6 047.161.0 02 Flush Valve for 11-1/2" Supply C\L
to top of bowl, 1.6 gpf
❑ 6 047.16 2 .0 0 2 Flush Valve for 27" Supply C\L to
top of bowl, 1.6 gpf
❑ 6047.565.002 Retrot for existing ush valves,
1.6 gpf. Replaces industry standard manual &
electronic ush valves. Does not include vacuum
breaker assembly, angle stop & sweat solder kit.
OPERATING PRESSURE:
Overall Range: 20-125 psi**
Recommended: 25 psi (owing)-80 psi (static)
GENERAL DESCRIPTION:
Manual Piston-Type Water Closet Flush Valve for
oor-mounted or wall-hung 1-1/2" top spud bowls.
INCLUDES:
• 1" I.P.S. angle stop with back-ow prevention and
vandal-resistant cap
• Sweat solder kit including cover tube and wall ange
• High back pressure vacuum breaker with down tube
• Spud coupling & ange for 1-1/2” top spud
PRODUCT FEATURES:
• Self-cleaning brass piston with integral wiper spring
prevents clogging and reduces maintenance
• Piston operation delivers superior ush accuracy and
repeatability
• Piston valve remains closed and does not need to be
reset after loss of water pressure
• Non-hold open handle
• Positive seal ensures leak-free performance
• No external volume adjustment
• Durable chrome-plated cast brass construction
is ideal for commercial applications
• Chloramine-resistant EPDM seals
• Adjustable tailpiece for rough-in exibility
• Can be installed left or right handed
• ADA complaint
** Water pressure over 80 psi is not recommended
for most plumbing xtures.
FLOW REQUIREMENT:
25gpm (94.6 L/min.)
ACCESSORIES:
• Cast wall anges (3/4", 1" & 1-1/2")
• Solid ring pipe supports (2-1/2" & 6" C-E)
• Split ring pipe supports (2-1/2" & 6" C-E)
TYPICAL WATER CLOSET INSTALLATION:
AFWALL™ TOILET SHOWN
FINISHED WALL
SUPPLY
ON BACK
DN 25mm
(1" I.P.S.)
FINISHED
FLOOR
121mm, +/-13mm
(4-3/4")(+/-1/2")
343mm
(13-1/2")
(11-1/2")
295mm
-C-L-
73mm
(2-7/8")
CRITICAL
LEVEL
SEE ROUGH-IN
RECOMMENDED SPECIFICATION:
Manual toilet flush valve shall feature self-cleaning brass piston valve with integral wiper spring in bypass orifice to prevent clogging. Valve
remains closed and does not need to be reset after loss of water pressure. Includes cast brass valve body and cover with chrome finish and
vandal resistant stop cap. Includes sweat solder kit with wall flange and cover tube. Angle stop with back-flow protection and vacuum breaker included.
1.6 gpf / 6.0 Lpf Flush valve shall be American St andard Model # 606 5.16_.002.
© 2012 AS America Inc.
L205
Revised
LISTINGS:
• ASSE 1037
• ANSI/ASME A112.19.2
• ADA Compliant
Roughing-in Dimensions
MANUAL TOILET
FLU SH VALVE
1.6 GPF
FINISHED WALL
38mm-127mm
(1-1/2"-5")
SUPPLY
DN 25mm
(1" I.P.S.)
*Note: The Critical Line (-C-L-) on Vacuum Breaker
must typically be a minimum of 6
fixture. Consult Codes for details.
108mm-133mm
(4-1/4" to 5-1/4")
-C-L-
*CRITICAL
LEVEL
" (152mm) above
6047.162
ROUGH-IN
DIMENSION
687mm
FOR 1-1/2" TOP
SPUD FIXTURES
(27")
6047.161
ROUGH-IN
DIMENSION
(11-1/2")
295mm
6047.162
735mm
(29")
6047.161
343mm
(13-1/2")
MEETS THE AMERICANS WITH DISABILITIES ACT GUIDELINES
AND ANSI A117.1 REQUIREMENTS FOR ACCESSIBLE AND
USABLE BUILDING FACILITIES-CHECK LOCAL CODES
© 2012 AS America Inc.
Left or Right Hand Installation
L206
Revised