American Standard 6047.111.002 User Manual

MANUAL FloWise
TYPICAL WATER CLOSET INSTALLATION:
+/-13mm
EXPOSED TOILET FLUSH VALVE
1.1 G PF
MODEL NUMBER:
6 0 47.111.0 0 2 Flush Valve for 11-1/2" Supply C\L
to top of bowl, 1.1 gpf
NOTICE: To ensure proper performance, this 1.1 gpf (4.2 Lpf) Toilet Flush Valve must be installed on a ushom­eter bowl that is certied (per ASME A112.19.2/CSA B45.1) to operate at 1.1 gpf (4.2 Lpf).
OPERATING PRESSURE:
Overall Range: 20-125 psi** Recommended: 25 psi (owing)-80 psi (static)
** Water pressure over 80 psi is not recommended for most plumbing xtures.
®
GENERAL DESCRIPTION:
Manual Piston-Type Water Closet Flush Valve for oor-mounted or wall-hung 1-1/2" top spud bowls.
INCLUDES:
• 1" I.P.S. angle stop with back-ow prevention and vandal-resistant cap
• Sweat solder kit including cover tube and wall ange
• High back pressure vacuum breaker with down tube
• Spud coupling & ange for 1-1/2” top spud
PRODUCT FEATURES:
• Self-cleaning brass piston with integral wiper spring
prevents clogging and reduces maintenance
• Piston operation delivers superior ush accuracy and
repeatability
• Piston valve remains closed and does not need to be
reset after loss of water pressure
• Non-hold open handle provides automatic shut-off
after every ush
• Fail-Safe Operation: Valve automatically closes and
does not need to be reset, on loss of water pressure
• Positive seal ensures leak-free performance
• No external volume adjustment
• Durable chrome-plated cast brass construction
is ideal for commercial applications
• Chemical-resistant EPDM seals for long life
• Adjustable tailpiece for rough-in exibility
FLOW REQUIREMENT:
25gpm (94.6 L/min.)
MaP* Score
• 1,000 grams of miso @ 1.1 gpf (when used with
an American Standard Afwall Millenium or Madera universal ushometer bowl)
*Maximum Performance (MaP) testing per formed by IAPMO R&T Lab. MaP Report conducted by Veritec Consulting, Inc. and Koeller and Comp any.
AFWALL™ TOILET SHOWN
FINISHED WALL
SUPPLY
DN 25mm
(1" I.P.S.)
FINISHED
FLOOR
121mm, (4-3/4")(+/-1/2")
343mm
(13-1/2")
(11-1/2")
295mm
73mm (2-7/8")
-C-L-
CRITICAL LEVEL
SEE ROUGH-IN
ON BACK
RECOMMENDED SPECIFICATION:
Manual toilet flush valve shall feature self-cleaning brass piston valve with integral wiper spring in refill orifice to prevent clogging. Valve remains closed and does not need to be reset after loss of water pressure. Includes cast brass valve body and cover with chrome finish and vandal resistant stop cap. Includes sweat solder kit with wall flange and cover tube. High back pressure vacuum breaker and angle stop with back-flow protection and vacuum breaker included. 1.1 gpf / 4.2 Lpf Flush valve shall b e Ameri can S tan dard Model # 6 047.111.002.
© 2014 AS America Inc.
L221
Revised
Roughing-in Dimensions
MANUAL FloWise
EXPOSED TOILET FLUSH VALVE
1.1 G PF
FINISHED WALL
38mm-127mm
(1-1/2"-5")
®
SUPPLY DN 25mm (1" I.P.S.)
*Note: The Critical Line (-C-L-) on Vacuum Breaker must typically be a minimum of 6 fixture. Consult Codes for details.
108mm-133mm
(4-1/4" to 5-1/4")
-C-L-
*CRITICAL
LEVEL
" (152mm) above
6047.122
ROUGH-IN
DIMENSION
687mm
FOR 1-1/2" TOP SPUD FIXTURES
(27")
6047.121
ROUGH-IN
DIMENSION
(11-1/2")
295mm
6047.122
735mm
(29")
6047.121
343mm
(13-1/2")
MEETS THE AMERICANS WITH DISABILITIES ACT GUIDELINES AND ANSI A117.1 REQUIREMENTS FOR ACCESSIBLE AND USABLE BUILDING FACILITIES-CHECK LOCAL CODES