MANUAL FLUSH VALVE, 1.0 GPF
C
o
E
E
/m
d
Exposed Flushometer for 1-1/4" top spud Urinals
FOR TOP SPUD APPLICATIONS
R TOP SPU
CLOG RESISTANT
• Self-cleaning piston valve prevents clogging and reduces maintenance.
• Self-cleaning pist
MODEL NUMBERS
6045.601
OPERATING PRESSURE:
PERATING PR
• Overall Range: 20-125 psi **
• Overall Range:
• Recommended: 25 psi (flowing) - 80 psi (static)
• Recommended:
FLOW REQUIREMENT:
FLOW REQUIR
• 10gpm (37.9 L/min).
• 10gpm (37.9 L
• Flush valves include sweat solder kit.
• Flush valves inclu
**Water pressure over 80 psi is not recommended with most plumbing fixtures
Certified to comply with:
• ASSE 1037
• ANSI/ASME A112.19.2
• ADA Compliant
© 2012 AS America, Inc.
Installation Instructions
M965364
NOTE TO INSTALLER: Please give this manual to the customer after installation.
To learn more about American Standard Faucets visit our website at: www.americanstandard.com or U.S. customer's e-mail us at: faucetsupport@americanstandard.com
For Parts, Service, Warranty or other Assistance,
please call
1-800-442-1902 (In Canada: 1-800-387-0369)
(In Toronto Area only: 1-905-3061093)
(In Toronto Area only: 1-905-3061093)
Thank you for selecting American-Standard...the benchmark of fine quality for over 100 years. To ensure that your
In st al la ti on I ns tru ct io ns
T
A
g pisto
ING PR
E
nge: 2 d:
EQUIRE
9 L/m
Flush valves
includ
OP SP
U
installation proceeds smoothly--please read these instructions carefully before you begin.
UNPACKING
All American Standard Products Are Water Tested At Our Factory. Some Residual Water May Remain In The Valve During Shipping.
1. Remove the Flush Valve items from the carton. The illustration below shows all items after they have been removed from the carton. Some items may be packaged partially assembled to other items.
1. Flush Valve Assembly
2. Down Tube and Vacuum Breaker
3. Spud Coupling Nut and Washers
4. Spud Flange
5. Sweat Solder Adapter
6. Cover Tube
7. Wall Escutcheon
8. Supply Stop
9. Installation Instructions
CARE INSTRUCTIONS:
DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.
DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A CLOTH WITH A COARSE SURFACE.
6
5
8
7
1
2
3
9
MANUAL FLUSH VALVE, 1.0 GPF
Exposed Flushometer for 1-1/4" top spud Urinals
FOR TOP SPUD APPLICATIONS
CLOG RESISTANT
OG
• Self-cleaning piston valve prevents clogging and reduces maintenance.
• Self-cleanin
OPERATING PRESSURE:
• Overall Range: 20-125 psi **
• Overall Ra
• Recommended: 25 psi (flowing) - 80 psi (static)
• Recommende
FLOW REQUIREMENT:
LOW R
• 10gpm (37.9 L/min).
• 10gpm (37.
• Flush valves include sweat solder kit.
**Water pressure over 80 psi is not recommended with most plumbing fixtures
Certified to comply with:
• ASSE 1037
• ANSI/ASME A112.19.2
• ADA Compliant
© 2012 AS America, Inc.
Installation Instructions
M965364
MODEL NUMBERS
6045.601
4
NOTE TO INSTALLER: Please give this manual to the customer after installation.
To learn more about American Standard Faucets visit our website at: www.americanstandard.com or U.S. customer's e-mail us at: faucetsupport@americanstandard.com
For Parts, Service, Warranty or other Assistance,
1-800-442-1902 (In Canada: 1-800-387-0369)
please call
1
(In Toronto Area only: 1-905-3061093)
(In Toronto Area only: 1-905-3061093)
M9653634
Fig. 1
Roughing-in Dimensions
108mm-133mm
(4-1/4" to 5-1/4")
SUPPLY DN 32mm (1" I.P.S.)
*CRITICAL
LEVEL
-C-L-
3/4" VACUUKM BREAKER SHOWN
152mm
(6)
(Min.)
295mm
(11-1/2")
FINISHED WALL
38mm-127mm
(1-1/2-5")
135mm
(13-1/2")
-C-L-
GENERAL DESCRIPTION:
MANUAL FLUSH VALVE, 1.0 GPF
Exposed Flushometer for 1-1/4" Top Spud Fixtures
Exclusive, self cleaning piston-operated flush valve.
OPERATING PRESSURE:
Overall Range: 20-125 psi ** Recommended: 20 psi (flowing)­80 psi (static)
FLOW REQUIREMENT:
10gpm (37.9 L/min).
**Water pressure over 80 psi is not recommended with most
plumbing fixtures
*Note: The Critical Line (-C-L-) on Vacuum Breaker must typically be 6
Consult Codes for details.
" (152mm) minumim above fixture.
RECOMMENDED TOOLS; Fig. 2
1.
Teflon Tape
2.
Flat Blade Screwdriver (For adjusting Supply Stop)
3.
Adjustable Wrench
4.
Tape Measure
5.
Hacksaw
6.
Tubing Cutter
7.
File
8.
For Sweat Connection; Solder and Torch
9.
2.5mm Hex Wrench
10.
1.5mm Hex Wrench
Fig. 2
Right or Left Hand Installation
See (Section 8) for converting Flush Valve to Left Hand Installation.
1
2
4
10'
3
6
5
8
7910
PRIOR TO INSTALLATION
Note: Prior to installing the Selectronic™Flush Valve
the following items must be installed.
1. Urinal
2. Drain line
3. Water supply line
IMPORTANT:
• All plumbing must be installed in accordance with applicable codes and regulations.
• Water supply lines must be sized to provide an adequate volume of water for each fixture.
• Flush all water lines prior to operation (See Step 5). Dirt and debris can cause flush valve to run continuously.
• With the exception of Supply Stop Inlet, DO NOT use pipe sealant or plumbing grease on any valve component or coupling!
• Protect the chrome or special finish on the Flushometer. DO NOT USE toothed tools on finished surfaces to install or service these valves. Also see “Care and Cleaning” section of this manual.
• This product contains mechanical and/or electrical components that are subject to normal wear. These components should be checked on a regular basis and replaced as needed to maintain the valve’s performance.
M9653634