American Standard 6011, 6012 User Manual

Installation
Instructions
SWAN
IN WALL PRESSURE BALANCING BATH AND SHOWER SETS
Thank you for selecting American-Standard...the benchmark of fine quality for over 100 years.
To ensure that your installation proceeds smoothly--please read these instructions carefully before you begin.
6011 6012
To assure proper positioning in relation to wall, note roughing-in dimensions.
4" REF.
74" FOR HEAD
CLEARANCE
18" OPTIONAL
SLIP-ON
SPOUT
TOP OF TUB RIM
FINISHED WALL
5-1/2" REF.
1-1/2"
5" REF.
MIN.
1/2" NPT
1-5/8"
to
3-1/4"
7-1/8"
1/2" COPPER
BETWEEN 65'' AND 80''
OPTIONAL TO FINISHED
FLOOR USUALLY
4"
Required Tools
INLETS 1/2" NPT
3-3/8"
3-3/8"
OUTLETS 1/2" NPT
THREADED INLETS
Phillips Screwdriver
Tubing Cutter
Plumbers' Putty or Caulking
OUTLETS 1/2" NPT
3-3/8"
Certified to comply with ANSI A112.18.1
Flat Blade Screwdriver
Adjustable Wrench
Channel Locks
5-7/8"
M968462S-O
INLETS
1/2" NPT
THREADED INLETS (STOPS)
BOTTOM OF TUB
ROUGHING-IN
1
NOTE
When soldering, remove PLASTER GUARD, CARTRIDGES and CHECK STOPS (IF PRESENT). When finished soldering, flush valve body, replace cartridges, check stops (if present) and plaster guard to continue installation. Use thread sealant or Teflon tape on threaded connections.
CAUTION
See Roughing-in diagram before starting. Connections are: 1/2" female NPT for threaded inlets Connect RISER PIPE (1) to MANIFOLD (2) top outlet marked "SHR". Connect TUB FILLER PIPE (3) at bottom outlet marked "TUB". For proper positioning the finished wall must be within side wall of PLASTER GUARD (4).
Turn off water at main supply.
If the valve is installed on a fiberglass or other thin wall application, the PLASTER GUARD (4) can be used as a support.
Cut a 4" dia. hole in the shower stall. Drill two additional 1" holes to allow access to the stops. Remove PLASTER GUARD (4), rotate 90˚ so that indicated screw holes fit MANIFOLD (2). Push CAP on valve, place ESCUTCHEON on and attach with screws.
Connect hot and cold water supplies. Cap off shower pipe (5) and tub filler pipe (6). For support, use pipe BRACES (7) secured to wooden braces. With valve turned off, turn on water supplies. Check for leaks.
1
2
HOT
5
7
COLD
4
3
6
INSTALL TRIM
2
CAUTION: Protect finish on SHOWER ARM, SHOWER HEAD and TUB SPOUT when installing.
When finished tiling the wall, remove PLASTER GUARD (A) and turn off water supply.
Push CAP (1) over VALVE CARTRIDGE (2).
Mount ESCUTCHEON (3) and gasket to valve body with SCREWS (4).
INSTALL HANDLE
3
Push ADAPTER (3) onto VALVE STEM (4).
Install SCREW (2) through ADAPTER (3) into VALVE STEM (4).
Find correct position of HANDLE (1) and push HANDLE (1) onto ADAPTER (3).
Remove PIPE CAP (5) from shower pipe. Use sealent on both ends of SHOWER ARM (6) and thread long end into shower elbow. Thread SHOWER HEAD (7) to SHOWER ARM (6).
Remove PIPE CAP (9). Use tubing cutter to cut tub filler pipe a minium of 1-1/2" from finished wall. Install SLIP-ON SPOUT (8) with flange flush against finished wall and tighten with a 4mm (5/32") hex wrench.
SHOWER ARM FLANGE
6
5
7
A
2
1
Install SET SCREW (5) with (2.5mm) HEX WRENCH (6) provided.
Check proper operation of HANDLE (1).
Turn on water supply and test installed fitting. Operate valve and diverter spout.
4
2
1
3
5
6
1-1/2"
MIN.
9
SPOUT FLANGE
ADJUST HOT LIMIT STOP
4
4mm (5/32") HEX WRENCH
4
8
By restricting HANDLE rotation and limiting the amount of hot water allowed to mix with the cold, the HOT LIMIT SAFETY STOP (1) reduces risk of accidental scalding. To set the maximum hot water temperature of your faucet, all you need to do is adjust the setting on the HOT LIMIT SAFETY STOP (1).
Turn CARTRIDGE STEM (2) to the OFF position (coldest setting) before making adjustment to HOT LIMIT STOP (1). Use a flat blade screwdriver to pry free the HOT LIMIT SAFETY STOP (1). Pull forward and rotate counterclockwise one number to limit hot water temperature. Use ARROW (3) on CARTRIDGE (4) and NUMBERS (5) on HOT LIMIT STOP (1) for indication.
3
3
9
7
1
5
1
3
3
1
0
1
5
1
5
1
4
2
3
2
1
5
1
4
(Larger Numbers)
0 1 3 5 7 9 11 13 15
3
1
1
9
7
5
3
1
COLDER
HOTTER
(Smaller Numbers)
0 1 3 5 7 9 11 13 15
5
1
5
1
3
1
1
9
7
5
3
1
1