American Standard 4335.020.XXX User Manual

Installation
PEKOE EXTENDER
SINGLE CONTROL KITCHEN
Instructions
4335.020.XXX
POP-OUT SPRAY
Thank you for selecting American-Standard...the benchmark of fine quality for over 100 years.
To ensure that your installation proceeds smoothly--please read these instructions carefully before you begin.
Recommended Tools
Phillips Screwdriver
INSTALL FITTING
Channel Locks
Adjustable Wrench
Plumbers' Putty or Caulking
Certified to comply with ANSI A112.18.1M
M968582
Tubing Cutter
CAUTION
Make certain the SEAL (1) is properly seated in recess of faucet body.
Insert supply HOSES (2) and SHANK (3) through center hole of sink or mounting surface.
Assemble RUBBER WASHER (4), PLASTIC WASHER (5), METAL WASHER (6) and threaded LOCKNUT (7) onto SHANK (3) from underside of sink or mounting surface. Hand tighten LOCKNUT (7) and check that faucet is centered.
Use a screwdriver to tighten SCREWS (8) on LOCKNUT (7). Work your way around LOCKNUT (7), tightening the screws slightly each time until all are snug to ensure even pressure.
Turn off hot and cold water supplies before beginning.
RECESS
4
5
3
1
2
6
7 8
MAKE WATER SUPPLY CONNECTIONS
Turn off hot and cold water supplies before beginning.
Connect FLEXIBLE SUPPLIES (1, 2) directly to wall supplies. Connection on fitting supplies are 3/8" compression. Connect left supply (Marked with a Red Stripe) to Hot and right supply (Marked with Blue Stripe) to Cold wall supply. Use adjustable wrench to tighten connections. Do not over tighten.
RED
STRIPE
BLUE
STRIPE
Faucet supplies are 27-1/2" long from faucet base.
Note: If additional supply length is required, installer must purchase additional parts separately.
Important: If SUPPLY HOSES (1, 2) are too long, loop as illustrated to avoid kinking.
TEST INSTALLED FAUCET
3
3
Move HANDLE (1) into "off" position.
Unthread SPRAY END (2) from SPOUT (3).
Turn on water supplies and check connections for leaks
Operate HANDLE (1) on and off, hot and cold to flush water lines thoroughly. Replace SPRAY END (2).
Check all drain connections for leaks.
Move HANDLE (1) to "off" position.
2
1
HOT
.
3
COLD
2
1
HOT & COLD SUPPLIES
M968582
Loading...
+ 2 hidden pages