Installation
Instructions
THE
COLLECTION
by
™
Top Mount Kitchen Faucet
Thank you for selecting American-Standard...the benchmark of fine
quality for over 100 years.
To ensure that your installation proceeds smoothly--please read
these instructions carefully before you begin.
TOOLS REQUIRED
4271
Certified to comply with ASME A112.18.1M
M968413
INSTALL FAUCET and SPRAY
1
INSTALL FAUCET
Place FAUCET (1) in postion on sink or mounting surface.
Assemble and tighten LOCKNUTS (2) from underside of
sink or mounting surface. Hand tighten to secure FAUCET (1).
INSTALL SPRAY
FAUCET (1) can be installed with or without HAND
SPRAY (3). To install FAUCET (1) with HANDSPRAY (3)
thread PIPE CAP (4) counter-clockwise and remove.
Place the HOLDER (5) into the appropriate mounting
hole. Assemble the SPRAY HOLDER WING NUT (6)
onto the shank of SPRAY HOLDER (5) from below
and tighten.
Feed SPRAY HOSE (7) through HOLDER (4) so SPRAY (3)
sits in HOLDER (5).
From underneath sink, attach COUPLING NUT (8) of SPRAY
HOSE (7) to HOSE SHANK (9). Tighten COUPLING NUT (8)
firmly.
Turn off hot and cold water supplies before beginning.
Basin Wrench
CAUTION
Tubing Cutter
1
9
4
Plumbers' Putty or CaulkingAdjustable WrenchChannel Locks
3
5
SINK OR
MOUNTING
SURFACE
6
28
2
(HAND TIGHTEN)
7
MAKE WATER SUPPLY CONNECTIONS
2
NOTE: FLEXIBLE SUPPLIES OR BULL-NOSE RISERS MUST BE
PURCHASED SEPARATELY.
Connect water supply to FAUCET (1) with 1/2" IPS FLEXIBLE
SUPPLIES (2) or 3/8" O.D. BULL-NOSE RISERS (3 ).
1
1
Use adjustable wrench to tighten connections. Do not over
tighten. Be careful not to kink copper supply when bending.
Use tubing cutter to cut to proper length.
TEST INSTALLED FITTING
3
With HANDLES (1) in OFF position, turn on WATER
SUPPLIES (2) and check all connections for leaks.
Remove AERATOR (3).
Operate both HANDLES to flush water lines thoroughly.
Rotate SPOUT (4) in both directions.
Replace AERATOR (3).
Direct SPRAY (5) into sink and activate. Check hose
connections for leaks.
2
COUPLING NUT
3
FERRULE
4
1
1
3
5
2
SERVICE
4
To change direction of handle rotation, proceed as follows:
Turn valve to OFF position.
Pull out INDEX CAP (1) and remove HANDLE SCREW (2).
Pull off HANDLE (3).
Pull off STEM ADAPTER (4).
Remove SPRING CLIP (6).
Lift STOP WASHER (5), turn 90° and replace.
Replace SPRING CLIP (6) and STEM ADAPTER (4).
Reinstall HANDLE ASSEMBLY (1,2 & 3).
If spout drips, operate handles several times from OFF to ON position.
Do not force - handles turn only 90°.
CARE INSTRUCTIONS:
5
DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.
DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A CLOTH WITH A COARSE SURFACE.
90°
6
1
2
3
4
5
M968413