GREEN TEA™ 5' X 42" WHIRLPOOL
❏ 3574.018WC Whirlpool featuring System I
• Acrylic with berglass reinforcement
• Pre-leveled tub bottom
• Form- tted backrest position
• Raised neck support
• Dual, molded in arm rests
• 1.4 HP single speed, self-draining pump/motor
• Factory installed power cord with plug
• Eight multi-directional and ow-adjustable jets
• Side-mounted air switch On/Off
• Can be under-mount installed
• Two silent air volume controls
• Quick Connect Safe-T-Heater
connection system
• Factory installed and tested whirlpool system
• EverClean™ whirlpool system
❏ 3574.002 Bathing Pool
• Same as above without whirlpool system
GREEN TEA™ 5' x 42"
WHIRLPOOL AND BATHING POOL
HIGH GLOSS
Nominal Dimensions:
1524 x 1067 x 533mm
(60" x 42" x 21")
Compliance Certi cations Meets or Exceeds the Following Speci cations:
• Underwriters Laboratories - Hydromassage
Bathtubs UL 1795
• ASME A112.19.7M for Whirlpool Appliances
• ANSI Z124.1 for Plastic Bathtubs
• ASTM E162 for Flammability
• NFPA 258 for Smoke Density
The EverClean™ system incorporates AlphaSan®, a
patented antimicrobial agent manufactured right into the
circulation system components, which suppresses the
growth of unsightly algae, fungus, mold and mildew.
SEE REVERSE FOR ROUGHING-IN DIMENSIONS AND
PRODUCT SPECIFICATIONS
To B e S p e c i ed - Required:
❏ Color:
❏ Bath Filler: (specify nish)
❏ Bath Drain: 1583.470 (specify nish)
To Be Speci ed - Optional:
❏ Safe-T-Heater*: 9075.120
❏ Jet Trim Ring Kit: 9860.200-two per kit (Specify nish)
for Body Massage Jets only
❏ Universal Tile Bead Kit: 751755-100
For color/ nish availability and other faucet choices, please
see the Product Selector and Pricing Guide.
* NOTE: the Safe-T-Heater is designed to maintain water
temperature during operation. It will not heat cold water to
desired bathing temperature.
AlphaSan is a registered trademark of Milliken & Co.
© 2007 American Standard Inc.
H7
Rev. 11/07
GREEN TEA™ 5' x 42"
WHIRLPOOL AND BATHING POOL
HIGH GLOSS
60
(1524mm)
OUTLINE OF CUTOUT 58.5 x 34.5 (1486 x 876mm)
PUMP
CUTOUT IN FLOOR FOR DRAIN
PROVIDE ACCESS TO PUMP FOR
SERVICE ON ALL INSTALLATIONS
C/L OF OVERFLOW
4
(102mm)
ROUGH
FLOOR
INTEGRAL FEET
LEVELING STRINGER NOT
FOR SUPPORT
21
(533mm)
ON/OFF
SWITCH
GENERAL SPECIFICATIONS FOR 3574 WHIRLPOOL
INSTALLED SIZE
WEIGHT
WEIGHT w/WATER
GAL. TO OVERFLOW
MIN. OPERATING GAL.
BATHING WELL AT SUMP
BATHING WELL AT RIM
WATER DEPTH TO OVERFLOW
FLOOR LOADING
(PROJECTED AREA)
PTS.
CUBE (FT3)
59-3/4 x 42 x 21 In. (1518 x 1060 x 533mm)
WHIRLPOOL ELECTRICAL SPECIFICATIONS
14-3/4
(375mm)
11-1/2
(292mm)
42
(1067mm)
9
(229mm)
(2) AIR VALVES
2
(51mm)
19
(483mm)
SAFE-T-HEATER
REMOVABLE
BLANK
24-1/2 x 42 In. (622mm x 1067mm)
48 x 33 In. (1219mm x 838mm)
38 Lbs./Sq. Ft. (185 Kgs/Sq. m.)
1.4 HP, 7.5 AMPS, 120V.SYSTEM I PUMP
C
115 Lbs. (52 Kg.)
656 Lbs. (298 Kg.)
65 Gal. (246 L.)
47 Gal. (178 L.)
14 In. (356mm)
60
(1524mm)
OUTLINE OF CUTOUT 58.5 x 34.5 (1486 x 876mm)
L
CUTOUT IN FLOOR FOR DRAIN
C/L OF OVERFLOW
4
(102mm)
ROUGH
FLOOR
INTEGRAL FEET
LEVELING STRINGER NOT
FOR SUPPORT
21
(533mm)
(229mm)
GENERAL SPECIFICATIONS FOR 3574
59-3/4 x 42 x 21 In. (1518 x 1060 x 533mm)
24-1/2 x 42 In. (622mm x 1067mm)
27.8
47.4
INSTALLED SIZE
WEIGHT
WEIGHT w/WATER
GAL. TO OVERFLOW
BATHING WELL AT SUMP
BATHING WELL AT RIM
WATER DEPTH TO OVERFLOW
FLOOR LOADING
(PROJECTED AREA)
PTS.
CUBE (FT3)
14-3/4
(375mm)
11-1/2
(292mm)
42
(1067mm)
9
2
(51mm)
19
(483mm)
C
L
BATHING POOL
78 Lbs. (35 Kg.)
619 Lbs. (281 Kg.)
65 Gal. (246 L.)
48 x 33 In. (1219mm x 838mm)
36 Lbs./Sq. Ft. (175 Kgs/Sq. m.)
14 In. (356mm)
27.8
47.4
NOTES:
BATH CAN BE INSTALLED EITHER ABOVE OR BELOW FLOOR LINE AS PIER, ISL AND, OR PENINSULA TYPE INSTALLATION. SUMP OF
BATH IS SUPPORTED BY INTEGR AL FEET. NO ADDITIONAL SUPPORT REQUIRED. ENCLOSING MATERIAL BY OTHERS.
■ REFER TO INSTALLATION INSTRUCTIONS SUPPLIED WITH WHIRLPOOL FOR ADDITIONAL INFORMATION.
OPTIONAL 3 WALL TILING BEAD. KIT AND APRON NO. 9260.018 OR 9360.018 AVAILABLE AND MUST BE ORDERED SEPARATELY.
● FITTINGS NOT INCLUDED AND MUST BE ORDERED SEPARATELY.
PROVIDE SUITABLE REINFORCEMENT FOR ALL SUPPORTS.
● IF INSTALLING A DECK-MOUNTED FITTING, BEFORE DRILLING ANY HOLES: CHECK FOR INTERFERENCE WITH CIRCULATING
SYSTEM PIPING, DRAIN OVERFLOW, AND APRON INSTALLATION. MOUNTING HOLES DRILLED BY INSTALLER.
IMPORTANT: Dimensions of xtures are nominal and may vary within the range of tolerances established by ANSI Standard Z124.1
These measurements are subject to change or cancellation. No responsibility is assumed for use of superseded or voided lea et.
© 2007 American Standard Inc.
H8
Rev. 11/07