American Standard 3571.018WC, 3571.002 User Manual

GREEN TEA™ 5' X 36" WHIRLPOOL
3571.018WC Whirlpool featuring System I
• Acrylic with  berglass reinforcement
• Pre-leveled tub bottom
• Raised neck support
• Dual, molded in arm rests
• 1.4 HP single speed, self-draining pump/motor
• Factory installed power cord with plug
• Eight multi-directional and  ow-adjustable jets
• Side-mounted air switch On/Off
• Can be under-mount installed
• Two silent air volume controls
• Quick Connect Safe-T-Heater connection system
• Factory installed and tested whirlpool system
• EverClean™ whirlpool system
3571.002 Bathing Pool
• Same as above without whirlpool system
GREEN TEA™ 5' x 36"
WHIRLPOOL AND BATHING POOL
HIGH GLOSS
Nominal Dimensions:
1524 x 914 x 533mm (60" x 36" x 21")
Compliance Certi cations ­Meets or Exceeds the Following Speci cations:
• Underwriters Laboratories - Hydromassage Bathtubs UL 1795
• ASME A112.19.7M for Whirlpool Appliances
• ANSI Z124.1 for Plastic Bathtubs
• ASTM E162 for Flammability
• NFPA 258 for Smoke Density
The EverClean™ system incorporates AlphaSan®, a patented antimicrobial agent manufactured right into the circulation system components, which suppresses the growth of unsightly algae, fungus, mold and mil­dew.
SEE REVERSE FOR ROUGHING-IN DIMENSIONS AND PRODUCT SPECIFICATIONS
To Be Speci ed - Required:
Color: Bath Filler: (specify  nish) Bath Drain: 1583.470 (specify  nish)
To Be Speci ed - Optional:
Safe-T-Heater*: 9075.120 Jet Trim Ring Kit: 9860.200-two per kit (Specify  nish)
for Body Massage Jets only Universal Tile Bead Kit: 751755-100
For color/ nish availability and other faucet choices, please see the Product Selector and Pricing Guide.
* NOTE: the Safe-T-Heater is designed to maintain water temperature during operation. It will not heat cold water to desired bathing temperature.
AlphaSan is a registered trademark of Milliken & Co.
© 2007 American Standard Inc.
H1
Rev. 11/07
GREEN TEA™ 5' x 36"
WHIRLPOOL AND BATHING POOL
HIGH GLOSS
60
(1524mm)
OUTLINE OF CUTOUT 58.5 x 34.5 (1486 x 876mm)
PUMP
CUTOUT IN FLOOR FOR DRAIN
PROVIDE ACCESS TO PUMP FOR SERVICE ON ALL INSTALLATIONS
C/L OF OVERFLOW
4
(102mm)
ROUGH
FLOOR
INTEGRAL FEET
LEVELING STRINGER NOT FOR SUPPORT
21
(533mm)
ON/OFF SWITCH
GENERAL SPECIFICATIONS FOR 3571 WHIRLPOOL
INSTALLED SIZE WEIGHT WEIGHT w/WATER GAL. TO OVERFLOW MIN. OPERATING GAL. BATHING WELL AT SUMP BATHING WELL AT RIM WATER DEPTH TO OVERFLOW FLOOR LOADING (PROJECTED AREA) PTS. CUBE (FT3)
WHIRLPOOL ELECTRICAL SPECIFICATIONS
14-3/4
(375mm)
11-1/2
(292mm)
36
(914mm)
9
(229mm)
(2) AIR VALVES
2 (51mm)
19
(483mm)
SAFE-T-HEATER REMOVABLE BLANK
60 x 36 x 21 In. (1524 x 914 x 533mm)
519 Lbs. (235 Kg.)
19 x 43 In. (483mm x 1092mm)
48-1/2 x 27 In. (1232mm x 686mm)
35 Lbs./Sq. Ft. (169 Kgs/Sq. m.)
1.4 HP, 7.5 AMPS, 120V.SYSTEM I PUMP
C
L
86 Lbs. (39 Kg.)
52 Gal. (197 L.) 38 Gal. (144 L.)
14 In. (356mm)
23.8
44.5
60
(1524mm)
OUTLINE OF CUTOUT 58.5 x 34.5 (1486 x 876mm)
CUTOUT IN FLOOR FOR DRAIN
C/L OF OVERFLOW
(102mm)
ROUGH
FLOOR
INTEGRAL FEET
LEVELING STRINGER NOT
4
FOR SUPPORT
21
(533mm)
9
(229mm)
14-3/4
(375mm)
2 (51mm)
19
(483mm)
GENERAL SPECIFICATIONS FOR 3571 BATHING POOL
INSTALLED SIZE WEIGHT WEIGHT w/WATER GAL. TO OVERFLOW BATHING WELL AT SUMP BATHING WELL AT RIM WATER DEPTH TO OVERFLOW FLOOR LOADING (PROJECTED AREA) PTS. CUBE (FT3)
60 x 36 x 21 In. (1524 x 914 x 533mm)
19 x 43 In. (483mm x 1092mm)
48-1/2 x 27 In. (1232mm x 686mm)
32 Lbs./Sq. Ft. (159 Kgs/Sq. m.)
11-1/2
(292mm)
36
(914mm)
54 Lbs. (24 Kg.)
487 Lbs. (221 Kg.)
52 Gal. (197 L.)
14 In. (356mm)
C
L
23.8
44.5
NOTES:
BATH CAN BE INSTALLED EITHER ABOVE OR BELOW FLOOR LINE AS PIER, ISLAND, OR PENINSULA TYPE INSTALLATION. SUMP OF BATH IS SUPPORTED BY INTEGR AL FEET. NO ADDITIONAL SUPPORT REQUIRED. ENCLOSING MATERIAL BY OTHERS.
REFER TO INSTALLATION INSTRUCTIONS SUPPLIED WITH WHIRLPOOL FOR ADDITIONAL INFORMATION.
OPTIONAL 3 WALL TILING BEAD. KIT AND APRON NO. 9260.018 OR 9360.018 AVAILABLE AND MUST BE ORDERED SEPARATELY.
FITTINGS NOT INCLUDED AND MUST BE ORDERED SEPARATELY.
PROVIDE SUITABLE REINFORCEMENT FOR ALL SUPPORTS.
IF INSTALLING A DECK-MOUNTED FITTING, BEFORE DRILLING ANY HOLES: CHECK FOR INTERFERENCE WITH CIRCULATING
SYSTEM PIPING, DRAIN OVERFLOW, AND APRON INSTALLATION. MOUNTING HOLES DRILLED BY INSTALLER.
IMPORTANT: Dimensions of  xtures are nominal and may vary within the range of tolerances established by ANSI Standard Z124.1 These measurements are subject to change or cancellation. No responsibility is assumed for use of superseded or voided lea et.
© 2007 American Standard Inc.
H2
Rev. 11/07
Loading...