INSTALLATION INSTRUCTIONS
Ravenna Wall-Hung Semi-Pedestal Sink
Introduction: Thank you for selecting our products...products which have been the benchmarks of
fine quality for years. To help insure that the installation process will proceed smoothly, please read these instructions carefully before you begin. Also, review the recommended tools and materials list; carefully unpack and examine your new plumbing fixture.
!
CAUTION: PRODUCT IS FRAGILE. TO AVOID BREAKAGE
AND POSSIBLE INJURY HANDLE WITH CARE!
NOTE: Pictures may not exactly define contour of china and components.
Recommended Tools & Materials
7/16" Wrench
9/16" Wrench
Level
Putty Knife
Pipe Wrench
Channel Lock Pliers
Drill
Plumbers' Putty or Caulking
Phillips Screwdriver
Tubing Cutter
Basin Wrench
Saber Saw
Regular Screwdriver
Pencil
Tape Measure
Hacksaw
3/16 Dia. Drill
9/32 Dia. Drill
*NOTE: for ease of installation and accessibility, it is recommended that straight stops with flex supply tubes be used. As an alternative, if rigid supply risers are used, it is suggested to use angle stops in place of the straight stops.
1
Provide Rough-in: Install waste
pipe 21" (533mm) up from the floor. Install the supplies at 24­3/4" (629mm) up from finished floor, spaced 1-1/2" (38mm) to either side of centerline. Firmly attach two 2" x 8" (50 x 203mm) wood braces to wall studs. Bottom of brace should be 26-1/2" (673mm) up from floor and extend a minimum of 6" (153mm) to either side of waste. Complete drywall installation (see figure 1).
2a
Drill (2) 9/32" dia. (7mm) holes 32" up from finished floor, spaced at 4-
SINK ANCHOR HOLES
SEMI-PEDESTAL/SHROUD ANCHOR HOLES
3/8" x 4"
HANGER
STUDS
(673mm)
3"
(76mm)
26-1/2"
C
9-1/2"
(241mm)
WASTE
21"
(533mm)
L
SUPPLIES
24-3/4"
(629mm)
32"
(813mm)
DRYWALL
DOUBLE
2" X 8"
50 X 203mm
WOOD BRACE
3/4" (120.6mm) either side of centerline. Install (2) 3/8" x 4" lg studs using the double nut method, leaving 1-5/8" of threaded end exposed. Mount the sink to studs temporarily, making sure the sink is level side to side.
Position semi-pedestal under bottom lip of sink. While
2b
holding semi-pedestal in position reach through the access
FINISHED FLOOR
area between the lavatory and semi-pedestal and mark the
1-5/8"
Lavatory
location of anchor holes. Remove semi-pedestal and predrill 3/16" (4-5mm) dia. holes at locations marked. Install 1/4" x 3" lg studs leaving 1-1/4" exposed. Use same anchor screw installation as in 2a.
Anchor Screw
Nut
Washer
ANCHOR SCREW INSTALLATION
Install lavatory anchor screws leaving
1-5/8" threaded end exposed as illustrated.
© American Standard Inc. 2003
Access
Pedestal Anchor Holes
730515-100 Rev. A
Remove lavatory top. Install faucet and pop-up assembly
3 5
("A") according to manufacturer's instructions before installing sink. Remount sink on the threaded end of wall studs. Firm up with washers and nuts, but do not over­tighten. It may be necessary to cut off part of the tailpiece (area "B") or part of the horizontal leg of the trap (area "C").
A
C
B
Connect water supplies lines and drain pipe
4
connections. Turn water on and check for leaks.
Shut-Off Valves
6
Mount Semi-Pedestal in position on threaded end of 1/4" studs using washers and nuts supplied.
Mounting Studs
Through the access space between pedestal and lavatory use a 7/16" wrench to tighten the pedestal to wall.
Access space
Illustration shown less wall supplies.
Flex Supplies
Drain Connections
AMERICAN STANDARD ONE-YEAR LIMITED WARRANTY
If inspection of this American Standard plumbing product, within one year after its initial installation, confirms that it is defective in
materials or workmanship, American Standard will repair or, at its option, exchange the product for a similar model.
This limited warranty does not apply to local building code compliance; since local building codes vary considerably, the purchaser of
this product should check with a local building or plumbing contractor to insure local code compliance before installation.
This warranty shall be void if the product has been moved from its initial place of installation; if it has been subjected to faulty maintenance, abuse, misuse, accident or other damage; if it was not installed in accordance with American Standard's instructions; or if it has been modified in a manner inconsistent with the product as shipped by American Standard.
American Standard's option to repair or exchange the product under this warranty does not cover any labor or other costs of removal or installation, nor shall American Standard be responsible for any other incidental or consequential damages attributable to a product defect or to the repair or exchange of a defective product, all of which are expressly excluded from this warranty. (Some states or provinces do not allow the exclusion or limitation of implied warranties, so this exclusion may not apply to you.)
This warranty gives you specific legal rights. You may have other statutory rights that vary from state to state or from province to province, in which case this warranty does not affect such statutory rights.
For service under this warranty, it is suggested that a claim be made through the contractor or dealer from or through whom the product was purchased, or that a service request (including a description of the product model and of the defect) be sent to the following address:
7
If installing optional towel bar (model 3520) it is recommended to install the towel bar after the sink and semi-pedestal are installed. (See instructions for towel bar.)
In the United States:
American Standard, Inc.
One Centennial Ave.
Piscataway, New Jersey 08855
Attention: Director of Consumer Affairs
Toll Free: (800) 442-1902
In Canada:
American Standard, Inc.
2480 Stanfield Rd.,
Mississauga, Ontario
Canada L4Y 1S2
Toll Free: (800) 387-0369
Customer Service Manager
In Mexico:
American Standard, Inc.
Via Morelos #330
Col. Santa Clara
Ecatepec 55540 Edo. Mexico
730515-100 Rev. A
Loading...
+ 1 hidden pages