Installation
Instructions
COLONY/COLONY SOFT
Bidet Faucet and Transfer Valve
with SpeedConnect™ Drain
Congratulations on purchasing your American
Standard faucet with Speed Connect drain, a
feature found only on American Standard faucets.
SpeedConnect Drain*
• Fewer parts, installs in less time
• Never needs adjustment
• Guaranteed to seal properly the first time, every time.
*Your new American Standard faucet is designed to work only with the SpeedConnect drain.
To ensure that your installation proceeds smoothly-please read these instructions carefully before you begin.
3475.300
3475.500
Certified to comply with ANSI A112.18.1
M968795Rev.1.1
Roughing-in
Dimensions
BIDET OUTLINE
IS SYMBOLIC
DOUCHE
SPRAY
3-7/8
BIDET FAUCET INSTALLATION
1
TRANSFER VALVE
(FOR FLUSHING
RIM OR SPRAY)
7/8 DIA.
ADJ. 1-1/4
TO 2-1/4
1-3/8
DIA.
5-1/2
FINISHED
WALL
2-1/8
DIA.
1-1/4 O.D. TAILPIECE
1-3/16
DIA.
1-1/4
MAX.
FINISHED
FLOOR
CAUTION
8 TO 12
(C)
Turn off hot and cold water
supplies before beginning.
(H)
2-1/4
DIA.
4-1/4
FOR GROUND JOINT
CONNECTION OR 1/2 "
O.D. SLIP (INLETS)
REAR VIEW WITH
WALL REMOVED
Place RUBBER RING (10) into ESCUTCHEON (4).
Install LOCKNUT (1) and RUBBER WASHER (2) onto VALVE BODIES (3, 3a). From
under side of mounting surface, install VALVE BODY (3, 3a) through valve mounting
holes. Threads of VALVE BODY (3, 3a) should extent at least 5/16 of a inch above
mounting surface top. Fig. A. Thread ESCUTCHEON (4) onto VALVE BODIES (3, 3a)
until snug against internal stop. If necessary, adjust LOCKNUT (1).
Tighten LOCKNUTS (1) with WRENCH (5) (supplied)
to secure VALVE BODIES (3, 3a).
Remove ESCUTCHEON (6), WASHER (7) and
UPPER GASKET (8) from TRANSFER VALVE (9).
Insert TRANSFER VALVE (9) into the center forward
Fig. A.
5/16''
MIN.
hole of BIDET.
Replace UPPER GASKET (8) and WASHER (7) and
ESCUTCHEON (6) until it locks against internal stop.
Position the side threaded outlet rearward and
secure MOUNTING NUT (11).
3, 3a
4
10
MOUNTING
SURFACE
2
1
Required tools
Screwdriver
Phillips Screwdriver
Adjustable Wrench
4
10
2
HOT
1
5
3
Plumbers' Putty or
Caulking
Channel Locks
Tubing Cutter
6
7
8
COLD
9
11
BIDET
LEDGE
3a
SPRAY INSTALLATION
2
Assemble SPRAY BODY (1) to BIDET. Using putty, seal underside
of SPRAY BODY FLANGE (2) and secure with NUT (3).
Thread SPRAY HOSE (4) with SEAL WASHER (5) to SPRAY BODY (1).
Connect other end of HOSE (4) with SEAL WASHER (6) to side outlet
NIPPLE (7) of the TRANSFER VALVE (8).
Thread SPRAY CAP (9) onto SPRAY BODY (1).
1
8
6
7
2
PUTTY
9
1
3
4
5
4
POP-UP DRAIN
3
Remove CLEAR PLASTIC COVER (1).
Remove CARDBOARD SPACER (2) from under
DRAIN POP-UP (3).
Fig. A. Fig. B.
1
3
DRAIN
BODY
Tighten TAILPIECE (4) on DRAIN BODY before
installing DRAIN BODY. Fig. B.
REMOVE FLANGE
4
Thread FLANGE (1) counter-clockwise and remove
FLANGE (1) and FOAM GASKET (2) from drain
body.
Fig. A.
Thread LOCKNUT (3) clock-wise to bottom of
drain body. Push GASKET (4) down against
LOCKNUT (3).
Fig. B.
2
Fig. A. Fig. B.
1
2
4
3
7
INSTALL DRAIN FROM
5
BELOW FIXTURE
From under side of BIDET
install DRAIN BODY (1) up
through drain outlet.
Note: No plumber’s putty
or caulk is required.
The CABLE ATTACHMENT
POINT (2) must face towards
the rear of the BIDET.
Install FOAM GASKET (3) and
FLANGE (4) onto drain body
from above BIDET and tighten
FLANGE (4) firmly.
FLANGE GASKET
7
Check DRAIN FLANGE in BIDET to ensure that WHITE
FOAM GASKET (1) is fully compressed and not visible.
Fig. A.
POP-UP ROD ASSEMBLY
Insert LIFT ROD GUIDE (1) and CABLE CONNECTOR (2)
through rear hole, making sure SEAL WASHER (3) is
properly seated. Fig. B.
From below slip slot in MOUNTING NUT (4) over CABLE (5).
Thread NUT (4) onto lift rod guide shank to secure ROD
GUIDE (1) to bidet. Hand tighten only. Fig. B.
4
3
DRAIN
OUTLET
1
2
Fig. A.
FLANGE
2
DRAIN
TIGHTEN LOCKNUT
6
Tighten LOCKNUT (1) firmly with Adjustable
Wrench or Channel Locks.
Fig. B.
WHITE FOAM
1
GASKET
NOT VISIBLE
ILLUSTRATION
SHOWN LESS
VALVES
M968795Rev.1.1
1
1
3
SLOTTED
MOUNTING
NUT
4
2