Congratulations on purchasing your American
Standard faucet with the Speed Connect drain, a
feature found only on American Standard faucets.
Speed Connect Drain*
• Fewer parts, installs in less time
• Never needs adjustment
• Guaranteed to seal properly the first time, every time.
*Your new American Standard faucet is designed to work only with the Speed Connect drain.
To ensure that your installation proceeds smoothly-please read these instructions carefully before you begin.
3475.500
Certified to comply with ANSI A112.18.1
M968677 Rev. 1.1
Roughing-in
Dimensions
BIDET OUTLINE
IS SYMBOLIC
DOUCHE
SPRAY
3-7/8
BIDET FAUCET INSTALLATION
1
TRANSFER VALVE
(FOR FLUSHING
RIM OR SPRAY)
7/8 DIA.
ADJ. 1-1/4
TO 2-1/4
1-3/8
DIA.
5-1/2
FINISHED
WAL L
2-1/8
DIA.
1-1/4 O.D. TAILPIECE
1-3/16
DIA.
1-1/4
MAX.
FINISHED
FLOOR
CAUTION
8 TO 12
(C)
Turn off hot and cold water
supplies before beginning.
(H)
2-1/4
DIA.
4-1/4
FOR GROUND JOINT
CONNECTION OR 1/2 "
O.D. SLIP (INLETS)
REAR VIEW WITH
WALL REMOVED
Place RUBBER RING (10) into ESCUTCHEON (4).
Install LOCKNUT (1) and RUBBER WASHER (2) onto VALVE BODIES (3, 3a). From
under side of mounting surface, install VALVE BODY (3, 3a) through valve mounting
holes. Threads of VALVE BODY (3, 3a) should extent at least 5/16 of a inch above
mounting surface top. Fig. A. Thread ESCUTCHEON (4) onto VALVE BODIES (3, 3a)
until snug against internal stop. If necessary, adjust LOCKNUT (1).
Tighten LOCKNUTS (1) with WRENCH (5) (supplied)
to secure VALVE BODIES (3, 3a).
Remove ESCUTCHEON (6), WASHER (7) and
UPPER GASKET (8) from TRANSFER VALVE (9).
Insert TRANSFER VALVE (9) into the center forward
Fig.A.
5/16''
MIN.
hole of BIDET.
Replace UPPER GASKET (8) and WASHER (7) and
ESCUTCHEON (6) until it locks against internal stop.
Position the side threaded outlet rearward and
secure MOUNTING NUT (11).
3, 3a
4
10
MOUNTING
SURFACE
2
1
Required tools
Screwdriver
Phillips Screwdriver
Adjustable Wrench
4
10
2
HOT
1
5
3
Plumbers' Putty or
Caulking
Channel Locks
Tubing Cutter
6
7
8
COLD
9
11
BIDET
LEDGE
3a
SPRAY INSTALLATION
2
Assemble SPRAY BODY (1) to BIDET. Using putty, seal underside
of SPRAY BODY FLANGE (2) and secure with NUT (3).
Thread SPRAY HOSE (4) with SEAL WASHER (5) to SPRAY BODY (1).
Connect other end of HOSE (4) with SEAL WASHER (6) to side outlet
NIPPLE (7) of the TRANSFER VALVE (8).
Thread SPRAY CAP (9) onto SPRAY BODY (1).
1
8
6
7
2
PUTTY
9
1
3
4
5
4
POP-UP DRAIN
3
Remove CLEAR PLASTIC COVER (1).
Remove CARDBOARD SPACER (2) from under
DRAIN POP-UP (3).
Fig.A.Fig.B.
1
3
DRAIN
BODY
Tighten TAILPIECE (4) on DRAIN BODY before
installing DRAIN BODY.
REMOVE FLANGE
4
Thread FLANGE (1) counter-clockwise and remove
FLANGE (1) and FOAM GASKET (2) from drain
body.
Fig.A.
Thread LOCKNUT (3) clock-wise to bottom of
drain body. Push GASKET (4) down against
LOCKNUT (3).
Fig. B.
Fig. B.
2
Fig. A.Fig. B.
1
2
4
3
7
INSTALL DRAIN FROM
5
BELOW FIXTURE
From under side of BIDET
install DRAIN BODY (1) up
through drain outlet.
Note: No plumber’s putty
or caulk is required.
The CABLE ATTACHMENT
POINT (2) must face towards
the rear of the BIDET.
Install FOAM GASKET (3) and
FLANGE (4) onto drain body
from above BIDET and tighten
FLANGE (4) firmly.
FLANGE GASKET
7
Check DRAIN FLANGE in BIDET to ensure that WHITE
FOAM GASKET (1) is fully compressed and not visible.Fig.A.
POP-UP ROD ASSEMBLY
Insert LIFT ROD GUIDE (1) and CABLE CONNECTOR (2)
through rear hole, making sure SEAL WASHER (3) is
properly seated. Fig.B.
From below slip slot in MOUNTING NUT (4) over CABLE (5).
Thread NUT (4) onto lift rod guide shank to secure ROD
GUIDE (1) to bidet. Hand tighten only. Fig.B.
4
3
DRAIN
OUTLET
1
2
Fig. A.
FLANGE
2
DRAIN
TIGHTEN LOCKNUT
6
Tighten LOCKNUT (1) firmly with Adjustable
Wrench or Channel Locks.
Fig.B.
WHITE FOAM
1
GASKET
NOT VISIBLE
ILLUSTRATION
SHOWN LESS
VALVES
M968677 Rev. 1.1
1
1
3
SLOTTED
MOUNTING
NUT
4
2
ATTACH CABLE
8
CONNECTOR
Fig. A.
Fig. B.
Fig. C.
POP-UP KNOB (1) must be fully
down. Fig.A.
Thread CABLE CONNECTOR (1)
clockwise onto DRAIN BODY
CONNECTION (2) and hand
tighten. Fig.B.
Your new POP-UP DRAIN
installation is now complete.
Fig. C.
Note: Tailpeice on pop-up drainis 1-1/4” O.D. Fig. C.
CHECK OPERATION OF POP-UP
9
Operate LIFT KNOB (1) to verify that STOPPER (2)
opens and closes.
Note: If STOPPER (2) does not open and close properly
then refer to the “troubleshooting section” of these
instructions.
INSTALL DIVERTER KNOB
Push DIVERTER KNOB (1) onto HANDLE ADAPTER (2).
DOWN
1
2
1-1/4” O.D.
5
4
1
2
3
1
2
Push on RING (3) and tighten with SCREW (4).
Press on KNOB CAP (5).
Note: Screwdriver gap is for disassembling and should
point downwards.
10
Insert SEAL (1) into ADAPTER (2) and tighten ADAPTER (2) to
side of TRANSFER VALVE (3).
Install SEAL (4) into coupling nut of TEE (5) and tighten
connection to ADAPTER (2).
Connect HOSE COUPLING NUTS (6) to Hot and Cold valve
bodies and securely tighten.
WATER SUPPLY CONNECTION
NOTE: FLEXIBLE SUPPLIES OR BULL-NOSE RISERS NOT
INCLUDED AND MUST BE PURCHASED SEPARATELY.
Connect water supply to VALVE BODIES (7,7a) with
1/2" IPS FLEXIBLE SUPPLIES (8) or 3/8" O.D. BULL-NOSE
RISERS (9). Use adjustable wrench to tighten connections.
Do not over tighten. Be careful not to kink copper supply when
bending. Use tubing cutter to cut to proper length.
Connect HOT water supply to inlet of left SHANK and COLD
water supply to right SHANK using sealant, appropriate
connectors, and COUPLING NUTS.
Connect 1-1/4” O.D. tailpiece on POP-UP DRAIN to
waste outlet.
TEE AND HOSE CONNECTION
OUTLINE OF BIDET
7
1/2" PIPE
THREAD
2
FLEXIBLE
SUPPLIES
HOT
5
3
4
2
6
1
3/8 COMPRESSION
CONNECTION
6
Front
COLD
CONNECT TO
WASTE OUTLET
7a
COUPLING
NUT
9
3/8 O.D.
BULL-NOSE
RISERS
COMPRESSION
NUT
FERRULE
M968677 Rev. 1.1
3
11
INSTALL HANDLES
LEVER HANDLE
Turn HANDLE STEM (1) to "OFF" position.
Place the HANDLE ADAPTER (2) on the HANDLE STEM (1). Install the
ADAPTER SCREW (3) and tighten securely.
Position LEVER HANDLE (4) and place on ADAPTER (2). Install the
HANDLE SCREW (5) and tighten securely.
4
5
3
2
1
12
13
TEST INSTALLED FITTING
With HANDLES (1) in OFF position, turn on WATER
SUPPLIES (2) and check all connections for leaks.
Operate both HANDLES (1) to flush water
lines thoroughly.
Rotate TRANSFER VALVE (5) from rim wash to
spray several times to check operation.
CHECK DRAIN CONNECTIONS
Pull up POP-UP KNOB (3) and fill Sink with water. Check
that DRAIN STOPPER (4) makes a good seal and retains
water in Bidet. If STOPPER (4) does not seal properly,
please refer to “Troubleshooting Guide” in these instructions.
Push POP-UP KNOB (3) down and check all drain
connections and "P" trap for leaks. Tighten
if necessary.
OUTLINE OF BIDET
3
1
2
1
4
2
SPRAY
14
DO: SIMPLY RINSE THE PRODUCT
CLEAN WITH CLEAR WATER. DRY
WITH A SOFT COTTON FLANNEL
CLOTH.
DO NOT: DO NOT CLEAN THE
PRODUCT WITH SOAPS, ACID,
POLISH, ABRASIVES, HARSH
CLEANERS, OR A CLOTH WITH
A COARSE SURFACE.
CARE INSTRUCTIONS:
SERVICE
15
To change direction of handle
rotation, proceed as follows:
Turn VALVE to OFF position.
Loosen HANDLE SCREW (1) .
Pull HANDLE (2) off ADAPTER (4). Loosen ADAPTER
SCREW (3) and pull off ADAPTER (4).
Remove SPRING CLIP (7). Lift STOP WASHER (5),
turn 90° and replace. Replace SPRING CLIP (7).
Reinstall ADAPTER SCREW (4) and LEVER HANDLE (2).
Tighten HANDLE SCREW (1).
If spout drips, operate handles several
times from OFF to ON position. Do not
force - handles turn only 90˚.
4
1
2
3
4
90˚
5
6
7
M968677 Rev. 1.1
Loading...
+ 8 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.