MADERA™ 16-1/2" HEIGHT
MEETS THE AMERICANS WITH DISABILITIES ACT GUIDELINES
AND ANSI A117.1 REQUIREMENTS FOR ACCESSIBLE AND USABLE
BUILDING FACILITIES - CHECK LOCAL CODES.
• Floor mount ushometer valve toilet
• Vitreous china
• Low-consumption (6.0 Lpf/1.6 gpf)
• EverClean® surface inhibits the growth of
stain- and odor-causing bacteria, mold,
and mildew on the surface
• 10" or 12" roughing-in
• 16-1/2" rim height for accessible application
• Condensation channel
• Elongated bowl
• Powerful direct-fed siphon jet action
• Fully glazed 2-1/8" trapway
• 10" x 12" water surface area
• 1-1/2" inlet spud
• 2 bolt caps
• 100% factory ush tested
❏ 3461.160 Elongated bowl only, top spud
❏ 3462.160 Elongated bowl only, top spud with
slotted rim for bedpan holding (White only)
❏ 3465.160 Elongated bowl only, top spud
with 4 bolts
❏ 3466.160 Elongated bowl only, top spud
with slotted rim for bedpan holding with 4 bolts
(white only)
❏ 3463.160 Elongated bowl only, back spud
❏ 3464.160 Elongated bowl only, back spud
with slotted rim for bedpan holding (White only)
MADERA™ 16-1/2" HEIGHT
1.6 GPF FLUSHOMETER TOILET
SEE REVERSE FOR ROUGHING-IN DIMENSIONS
Component Parts:
❏ 047007-0070A Inlet spud (furnished with bowl)
❏ 481310-100 Bolt caps with retainers
(furnished with bowl)
Nominal Dimensions:
718 x 356 x 419mm
(28-1/4" x 14" x 16-1/2")
Recommended working pressure–between
25 psi at valve when ushing and 80 psi static
Fixture only, less seat and ush valve
Compliance Certications Meets or Exceeds the Following Specications:
• ASME A112.19.2 for Vitreous China Fixtures
• CAN/CSA International B45
© 2008 AS America Inc.
To Be Specied:
❏ Color: ❏ White ❏ Bone ❏ Silver ❏ Linen ❏ Black
❏ Seat:
❏ American Standard #5901.100 Heavy duty open
front less cover
❏ American Standard #5905.100 Extra heavy duty
open front less cover
❏ Flushometer Valve:
❏ American Standard Selectronic™ #6065.161.002
DC Power(Top Spud)
❏ American Standard Selectronic™ #6065.261.007
DC Power (Back Spud)
❏ American Standard Selectronic™ #6067.261.007
AC Power (Back Spud)
❏ American Standard Selectronic™ #6068.261.007
Multi AC Power (Back Spud)
M57
Revised 12/08
238mm
(9-3/ 8)
419mm
(16-1 /2)
438mm
(17-1 /4)
470mm
(18-1 /2)
356mm
(14)
338mm
(13-5 /16)
150mm
(5-7/ 8)
254mm
(10)
13mm
(1/2)
76m m
(3)
718 mm
(28 -1/4)
C/L O F SEAT PO ST HOLES
140mm (5-1/2) CENTERS
FINIS HED WALL
FINIS HED
FLOOR
C/L O F OUTLET
MADERA™ 16-1/2" HEIGHT
711mm
(28)
1 - 1 /2
SPUD
121mm
(4-3/ 4)
238mm
(9-3/ 8)
419mm
(16-1 /2)
470mm
(18-1 /2)
356mm
(14)
338mm
(13-5 /16)
150mm
(5-7/ 8)
254mm
(10)
13mm
(1/2)
25m m
(1)
102 mm
(4)
718 mm
(28 -1/4)
C/L O F SEAT PO ST HOLES
140mm (5-1/2) CENTERS
FINIS HED WALL
FINIS HED
FLOOR
C/L O F OUTLET
1" N. P.T. OR 1 " C.W.T. SUPPLY
TO FL USH VALVE
1.6 GPF FLUSHOMETER TOILET
3461.160/3462.160/3465.160/3466.160
3463.160/3464.160
NOTES:
PRODUCT 3451.160 AND 3453.160 SHOWN, 3452.160 AND 3455.160
SAME AS EXCEPT WITH SLOTTED RIM FOR BED PAN HOLDING.
TO COMPLY WITH AREA CODE GOVERNING THE HEIGHT OF VACUUM
BREAKER ON THE FLUSHOMETER VALVE, THE PLUMBER MUST
VERIFY DIMENSIONS SHOWN FOR SUPPLY ROUGHING.
THIS TOILET DESIGNED TO ROUGH-IN AT A MINIMUM DIMENSION
OF 254MM (10") AND A MAXIMUM DIMENSION OF 305MM (12") FROM
FINISHED WALL TO C/ L OF OUTLET.
FLUSHOMETER VALVE NOT INCLUDED WITH FIX TURE AND MUST BE
ORDERED SEPARATELY. FLUSHOMETER VALVE REQUIREMENTS FOR
12" (305MM) ROUGH-IN: SWEAT EXTENSION NIPPLE IS REQUIRED.
REFER TO VALVE MANUFACTURER AND LOCAL CODES.
IMPORTANT: Dimensions of xtures are nominal and may vary within
the range of tolerances established by ANSI Standard A112.19.2. These
measurements are subject to change or cancellation. No responsibilit y is
assumed for use of superseded or voided pages.
© 2008 AS America Inc.
M58
Revised 12/08