American Standard 2984, 2794, 2989, Cadet 3 Concealed Trapway, 2985 User Manual

...
INSTALLATION INSTRUCTIONS CARE AND MAINTENANCE
Cadet® 3 Concealed Trapway Studio® Concealed Trapway
Right Height®, Elongated Model 2985, 2989, 2794 Right Height
Thank you for selecting American Standard - the benchmark of fine quality for over 100 years. To ensure this product is installed properly, please read these instructions carefully before you begin. (Certain installations may require professional help.) Also be sure your installation conforms to local codes.
CAUTION: PRODUCT IS FRAGILE. TO AVOID BREAKAGE AND POSSIBLE INJURY HANDLE WITH CARE!
!
NOTE: Pictures may not exactly define contour of china and components.
RECOMMENDED TOOLS AND MATERIALS
Putty Knife Regular Screwdriver Adjustable Wrench Sealant Tape Measure Hacksaw Wax Ring/Gasket Flexible Supply Tube Closet Bolts Carpenters Level
1 REMOVE OLD TOILET
a. Close toilet supply valve and flush tank completely. Towel or sponge remaining water from tank and bowl. b. Disconnect and remove supply line. NOTE: If replacing valve, first shut off main water supply! c. Remove old mounting hardware, remove toilet and plug floor waste opening to prevent escaping sewer gases. d. Remove closet bolts from flange and clean away old wax, putty, etc. from base area. NOTE: Mounting surface must be clean and level before new toilet is installed!
ROUGHING-IN DIMENSIONS:
2
NOTE: Distance from wall to closet flange centerline must be as listed below:
FINISHED WALL
1-1/8"
(29mm)
2-5/8"
(67mm)
3-1/8"
(81mm)
4-1/2"
(114mm)
12"
IMPORTANT: Water supply on the wall is required at 2-1/4" or 8" from centerline of the toilet (see rough-in).
FINISHED
First suggested position is hidden behind the toilet. The geometry of the toilet gives space for this installation.
WALL
The second suggested position is next to the toilet. Between these two positions, the space for the supply between wall and toilet is limited to 4-1/2". In this case, check your supply and hose dimensions.
1-1/8"
(29mm)
2-5/8"
(67mm)
3-1/8"
(81mm)
7-1/2"
(191mm)
®
, Round Front Model 2984, 2988, 2795
RIGHT HEIGHT ELONGATED 2-PIECE TOILET
30-1/4"
8-3/4"
C/L OF SEAT POST HOLES 5-1/2" (140mm) CENTERS
13-11/16" (347mm)
8-3/4"
(221mm)
(768mm)
18-1/2"
28-1/4"
(717mm)
C/L OF SEAT POST HOLES 5-1/2" (140mm) CENTERS
16-1/2"
(419mm)
16-1/2"
(419mm)
FINISHED
FLOOR
16-1/2"
(419mm)
SUPPLY
AS
REQUIRED
(position 1 or
position 2)
5-1/2"
(140mm)
RIGHT HEIGHT ROUND FRONT 2-PIECE TOILET
SUPPLY
AS
REQUIRED
(position 1
or
position 2)
5-1/2"
(140mm)
8"
8"
(204mm)
15-3/4"
12-3/16"
14"
2-1/4"
(57mm)
(152mm)
15-3/4"
(399mm)
14"
(356mm)
2-1/4"
(57mm)
6"
30-3/4"
30-3/4"
(781mm)
BACK VIEW (for reference)
Certified by
IAPMO R&T
IMPORTANT: Water supply
on the wall is required at
2-1/4" or 8" from centerline
of the toilet (see rough-in).
First suggested position is
hidden behind the toilet. The
geometry of the toilet gives
space for this installation.
The second suggested
position is next to the toilet.
Between these two
positions, the space for the
supply between wall and
toilet is limited to 4-1/2". In
this case, check your supply
and hose dimensions.
SAVE FOR FUTURE USE
4-1/2"
(114mm)
IMPORTANT: Water supply on the wall is required at 2-1/4" or 8" from centerline of the toilet (see rough-in).
Product names listed herein are trademarks of AS America, Inc.
First suggested position is hidden behind the toilet. The geometry of the toilet gives space for this installation.
© AS America, Inc. 2011
The second suggested position is next to the toilet. Between these two positions, the space for the supply between wall and toilet is limited to 4-1/2". In this case, check your supply and hose dimensions.
(191mm)
12"
(305mm)
7-1/2"
12-7/8"
(328mm)
FINISHED
FLOOR
12-3/16"
(309mm)
6"
(152mm)
BACK VIEW (for reference)
7301555-100 Rev. B
3
4
Press firmly.
5
TIP: Place 2 pieces of masking tape on floor (as shown) to help with alignment in step 6.
6
Apply weight evenly. Do not move after placement. Water tight seal may break.
9
Thread, then hand tighten water supply.
7
Hand Tighten Only.
!
Do Not Overtighten.
Tighten handles alternately
10
until tank contacts bowl.
HAND TIGHTEN ONLY!
8
For seat installation,
*
see instructions
included with seat.
- 2 -
!
WARNING:
Overtightening of water supply line nuts could result in breakage and potential flooding. If the connection leaks after hand tightening, replace the supply line. Do not use any type of sealant on the water supply connection.
Use of plumber’s putty,
!
pipe dope, or any other type of sealant will void the warranty.
7301555-100 Rev. B
Loading...
+ 2 hidden pages