Installation
TM
Widespread Lavatory Faucet with the
Speed Connect™ Drain
Congratulations on purchasing your American Standard faucet with
the Speed Connect Drain, a feature found only on
American Standard faucets.
Speed Connect Drain*
• 1/3 of the parts, installs in 1/3 of the time
• No tools needed
• Never needs adjustment
• Guaranteed to seal properly the first time, every time.
*Your new American Standard faucet is designed to work only with the Speed Connect drain. Helpful tips for
removing your current drain can be found in the Troubleshooting section of these instructions.
To ensure that your installation proceeds smoothly-please read these instructions carefully before you begin.
Recommended tools
Instructions
2808.222
2908.222
Certified to comply with ANSI A112.18.1
US60385 Rev. 1.2
1
1A
Adjustable Wrench Screwdriver Channel Locks
INSTALL SPOUT
Insert SPOUT (1) and CABLE CONNECTOR (2) through center hole, making sure
the SEAL WASHER (3) is properly seated in SPOUT (1).
Assemble RUBBER WASHER (4), BRASS WASHER (5) and LOCKNUT (6) onto SPOUT
SHANK (7) from under side of sink . Make sure SPOUT (1) is centered in the mounting
hole and the slot in the BRASS WASHER (5) faces toward the rear of the sink.
Tighten LOCKNUT (6) firmly. Fig. A.
INSTALL VALVE BODY
Place RUBBER RING (9) into ESCUTCHEON (10).
Install LOCKNUT (11) onto VALVE BODY (12).
From under side of mounting surface, install VALVE BODY (12) through valve
mounting holes. Threads of VALVE BODY (12) should extent at least 5/16
of a inch above mounting surface top. Fig. B.
Important: Thread ESCUTCHEON (10) onto VALVE BODY (12) until snug against
internal stop. This is key to the installation. If not done, the faucet handles won’t
work correctly. If necessary, adjust LOCKNUT (11).
Hand tighten LOCKNUT (11) to secure VALVE BODY (12).
Repeat above steps for opposite VALVE BODY (12A).
CAUTION
Turn off water at
main supply.
Tubing Cutter
Fig. A.
3
SLOT
1
7
4
5
6
2
10
9
5/16'' MIN.
Fig. B.
MOUNTING
SURFACE
11
12
10
9
12
11
1
12a
2808 SERIES
1
INSTALL POP-UP DRAIN
2
Remove CLEAR PLASTIC COVER (1).
Remove CARDBOARD SPACER (2) from
under DRAIN POP-UP (3).
Drop DRAIN BODY (4) through sink drain
hole. Make sure WHITE FOAM GASKET (5)
is under flange of DRAIN BODY (4).
Note: No plumber’s putty or caulk is required.
The CABLE ATTACHMENT POINT (6) must
face towards the rear of the SINK.
INSTALL BLACK GASKET
3
Install BLACK CONE GASKET (1) onto DRAIN BODY (2)
from below.
Note: The flat side of the BLACK CONE GASKET (1) must
face down.
Fig. A.
Fig. B.
Fig. B.
Fig. A. Fig. B.
1
3
2
2
REAR OF
SINK
4
6
5
SINK
DRAIN
HOLE
INSTALL GRAY LOCKNUT
4
Install GRAY LOCKNUT (1) onto DRAIN
BODY (2) from below SINK. Fig. A.
Note: The flat side of the GRAY LOCKNUT (1)
must face up.
Tighten firmly by hand. No tools are required.
Check DRAIN FLANGE in SINK to ensure that
WHITE FOAM GASKET (3) is fully compressed
and not visible. Fig. B.
POP-UP KNOB
5
POP-UP KNOB (1) must be fully down.
Fig. A.
1
FLAT SIDE OF GASKET
MUST FACE DOWN
Fig. B.
2
DRAIN
FLAT SIDE OF
GRAY LOCKNUT
MUST FACE UP
1
3
FLANGE
WHITE FOAM
GASKET
NOT VISIBLE
DOWN
1
US60385 Rev. 1.2
2