American Standard 2775.XXXW User Manual

CADET™ CORNER
HIGH GLOSS ACRYLIC SHOWN LESS ALL FITTINGS
2775.XXXW SERIES WHIRLPOOL
INSTALLATION INSTRUCTIONS
1080mm (42-1/2)
70mm REF. (2-3/4)
C/L
279mm (11)
C/L OF DRAIN OUTLET
RECOMMENDED FITTING LOCATION 64 X 330mm (2-1/2 X 13)
38 mm REF. (1-1/2)
ROUGH FLOOR
INTEGRAL
SUPPORT
FEET
1524mm
(60)
OUTLINE OF CUTOUT
1080 mm
(42-1/2)
C/L OF OVERFLOW
1-1/2 N.P.T.M.
THREADS
1-1/2 O.D. TAILPIECE
165mm (6-1/2)
2159mm
(85)
76mm (3)
GENERAL SPECIFICATIONS FOR 2775 WHIRLPOOL
INSTALLED SIZE WEIGHT WEIGHT w/WATER GAL. TO OVERFLOW MIN. OPERATING GAL. BATHING WELL AT SUMP BATHING WELL AT RIM WATER DEPTH TO OVERFLOW FLOOR LOADING (PROJECTED AREA) PTS. CUBE (FT3)
85 X 60 X 19-3/4In.(2159 X 1524 X 502mm)
32 X 32 In. (813 mm X 813 mm)
46 X 46 In. (1168 X 1168mm)
34 Lbs./Sq. Ft. (115 Kgs/Sq. m.)
WHIRLPOOL ELECTRICAL SPECIFICATIONS
2.1 HP, 14.4 AMPS, 120V.SYSTEM I PUMP
229 X 305mm (9 X 12) CUTOUT IN FLOOR FOR DRAIN
SAFE-T­HEATER REMOVABLE BLANK
ON/OFF SWITCH
PUMP
LEVELING STRINGER
NOT FOR SUPPORT
117mm
70mm
(4-5/8)
(2-3/4)
130 Lbs. (59 Kg.)
756 Lbs. (343 Kg.)
75 Gal. (284 L.) 60 Gal. (227 L.)
14 In. (356 mm)
1076mm (42-3/8)
1524mm
(60)
PROVIDE ACCESS TO PUMP FOR SERVICING ON ALL INSTALLATIONS
502mm (19-3/4)
464mm (18-1/4)
41.7
70.4
THANK YOU...
for selecting an American Standard bath. Your new bath is shipped to you after careful inspection. The whirlpool version is completely assembled with pump, motor, and system piping. All you need to finish the installation are your selected fittings and electrical connections for a whirlpool.
To insure maximum performance and pleasure from this product, please follow the instructions and cautions.
List of Optional Components (not included):
• Safe-T-Heater 9075.120*
• Tile Bead Kit 751755-100* * see your American Standard Dirstributor
List of Required Components (not included):
• Drain* 1583.470 • Bath Filler* * see your American Standard Dirstributor
List of Required Tools and Supplies: Tools
• Level
• Tape Measure
• Pipe Wrench
• Slip Joint Pliers
• Screw Driver
• Standard Woodworking Tools
• Personal Safety Equipment
• Caulking Gun
Supplies
• Nails
• Putty
• Caulking (waterproof)
• 1 x 3 or 2 x 2 Stringers
• Drop Cloth
• 20 amp GFI Outlet
• Cement, Plaster, Grout
GENERAL INSTALLATION INFORMATION
Carefully uncrate and inspect your new bath for any shipping damage. If such damage is found, report it to your vendor immediately.
After inspection and during installation, protect the bath from construction damage. After installation, and before enclosing with wallboard, tile, etc., water test the unit and check for leaks.
Do not make modifications to the whirlpool system or remove pump from factory mounting. This could adversely affect the safety and performance of the whirlpool and void the warranty. Do not handle or move the whirlpool by the pump, motor, or piping system.
Fittings (bath filler, shower arm, etc.) are not provided with the bath and must be ordered separately. Framing and enclosing materials are provided by others. Check for availability of optional American Standard wall tiling bead (required for recess installations).
Protect all finished surfaces of the whirlpool during construction and installation using a drop cloth.
WARNING! Do not lift whirlpool by the piping harness at any time.
FOR AFTER-SALES SERVICE CALL 1 (800) 442-1902 WEEKDAYS.
752536-100 Rev. G
© American Standard Inc. 2003 All product names listed herein are trademarks of American Standard Inc. unless otherwise noted.
INSTALLATION AND FRAMING INSTRUCTIONS
The variety of installations possible for this whirlpool may require framing procedures other than those shown. Locate studs as required. Ensure roughing-in dimensions are proper, plumb and square. Provisions must be made in all installations for an access opening for servicing the pump and controls. It is strongly recommended that an additional opening be provided for access to the drain components.
NOTE: The apron should not be used as the primary access opening.
1. Position the whirlpool into the installation opening and level the deck, shimming the integral support feet as necessary. Mark the final position of the underside of the deck by tracing a line on to the studs (see Figure 1).
2. Remove the whirlpool and attach a 2 x 4 stringer to the studs, with the top of the stringer touching the traced line.
3. Install drain components to the whirlpool following the manufacturers instructions. Before replacing your whirlpool for final installation, be certain that an opening has been provided in the sub-floor for the drain. See the roughing-in drawing for suggested opening size and location dimensions.
4. Replace whirlpool and re-shim the integral support feet, shimming the entire length of the support feet. Secure the shims using construction adhesive, silicone, mortar or equivalent materials. While not a necessity, the use of a foundation base consisting of cement (e.g. Sakrete), mortar, or grout will help provide a solid and secure installation.
FIG. 1
18-1/4"
(464mm)
SUGGESTED INSTALLATION METHODS
LEVELING SURFACE
WATERPROOF SEALANT
BATH
SUNKEN OR ISLAND
INSTALLATION
TILE BEAD STRIP
LEVELING STRINGER
RECESSED INSTALLATION
TILE
WATERPROOF SEALANT
BATH
TYPICAL CORNER INSTALLATION
58-1/2"
(1486mm)
18-1/4"
(464mm)
HEIGHT OF FRAMEWORK
INCLUDES PLYWOOD,
TILES,ETC.
SEE CUTOUT TEMPLATE PROVIDED
58-1/2"
(1486mm)
FRONT OR SIDE ACCESS PANEL REQUIRED FOR
PUMP SERVICING.
752536-100 Rev. G
(2)
UNLESS AN ACCESS OPENING OF AT LEAST
12" X 24" (305 X 610MM) IS PROVIDED,
WARRANTY SERVICE WILL NOT BE PERFORMED.
Loading...
+ 2 hidden pages