American Standard 2773.XXXW User Manual

CADET™ 6' x 36"
HIGH GLOSS ACRYLIC SHOWN LESS ALL FITTINGS
305 mm
(12)
SEE FITTING
SPECS FOR
DIMENSIONS
908 mm
(35-3/4)
229mm
FINISHED
454 mm (17-7/8)
(9)
WALL
19 mm
(3/4)
PROVIDE ACCESS TO PUMP FOR
SERVICING ON ALL INSTALLATIONS
1829 mm
(72)
RECOMMENDED FITTING LOCATION
64 X 330mm (2-1/2 x 13")
FOR PIER OR ISLAND
INSTALLATIONS ONLY
229 mm
(9)
CUTOUT IN FLOOR FOR DRAIN
2773.XXXW SERIES WHIRLPOOL/BATHING POOL
INSTALLATION INSTRUCTIONS
THANK YOU...
for selecting an American Standard bath. Your new bath is shipped to you after careful inspection. The whirlpool version is completely assembled with pump, motor, and system piping. All you need to finish the installation are your selected fittings and electrical connections for a whirlpool.
To insure maximum performance and pleasure from this product, please follow the instructions and cautions.
PUMP
ON/OFF SWITCH
C/L OF
SUPPLIES
OPTIONAL TO
FINISHED FLOOR
USUALLY BETWEEN
1651 & 1981mm
(65 & 78)
GENERAL SPECIFICATIONS FOR 2773 WHIRLPOOL
INSTALLED SIZE
WEIGHT WEIGHT w/WATER GAL. TO OVERFLOW MIN. OPERATING GAL. BATHING WELL AT SUMP BATHING WELL AT RIM WATER DEPTH TO OVERFLOW FLOOR LOADING (PROJECTED AREA) PTS.
CUBE (FT3)
57mm (2-1/4)
C/L OF DRAIN
C/L OF OVERFLOW
70mm (2-3/4)
502 mm (19-3/4)
ROUGH
FLOOR
INTEGRAL
SUPPORT
FEET
WHIRLPOOL ELECTRICAL SPECIFICATIONS
(8) JETS
305mm
38 mm (1-1/2)
1-1/2 N.P.T.M.
1-1/2 O.D.TAILPIECE
ALT. FITTING
LOCATION #1
(12)
102 mm
(4)
THREADS
(1829mm x 908 mm x 502mm)
23 x 49 In. (584 mm x 1245 mm)
65 x 29 In. (1651 x 737 mm)
40 Lbs./Sq. Ft. (190 Kgs/Sq. m.)
2.1 HP, 14.4 AMPS, 120V.PUMP
(2) AIR VALVES
C/L OF SHOWER ARM
C/L OF VALVES
C/L OF SPOUT
70 mm (2-3/4)
72 x 35-3/4 x 19-3/4 In.
101 Lbs. (45 Kg.)
751 Lbs. (341 Kg)
78 Gal. (295 L.) 64 Gal. (242 L.)
13-1/2 In. (343mm)
OUTLINE OF CUTOUT 1791 mm x 870 mm (70-1/2 X 34-1/4)
LEVELING STRINGER
464 mm (18-1/4)
117 mm
(4-5/8)
23.8
48.3
SAFE-T-HEATER REMOVABLE BLANK
NOT FOR SUPPORT
List of Optional Components (not included):
• Safe-T-Heater 9075.120*
• Tile Bead Kit 751755-100*
• Apron Kit* * see your American Standard Distributor
List of Required Components (not included):
• Drain 1583.470* • Bath Filler* * see your American Standard Distributor
List of Required Tools and Supplies: Tools
• Level
• Tape Measure
• Pipe Wrench
• Slip Joint Pliers
• Screw Driver
• Standard Woodworking Tools
• Personal Safety Equipment
• Caulking Gun
Supplies
• Nails
• Putty
• Caulking (waterproof)
• 1 x 3 or 2 x 2 Stringers
• Drop Cloth
• 20 amp GFI Outlet
• Cement, Plaster, Grout
GENERAL INSTALLATION INFORMATION
Carefully uncrate and inspect your new bath for any shipping damage. If such damage is found, report it to your vendor immediately.
After inspection and during installation, protect the bath from construction damage. After installation, and before enclosing with wallboard, tile, etc., water test the unit and check for leaks.
Do not make modifications to the whirlpool system or remove pump from factory mounting. This could adversely affect the safety and performance of the whirlpool and void the warranty. Do not handle or move the whirlpool by the pump, motor, or piping system.
Fittings (bath filler, shower arm, etc.) are not provided with the bath and must be ordered separately. Framing and enclosing materials are provided by others. Check for availability of optional American Standard wall tiling bead (required for recess installations).
Protect all finished surfaces of the whirlpool during construction and installation using a drop cloth.
WARNING! Do not lift whirlpool by the piping harness at any time.
FOR AFTER-SALES SERVICE CALL 1 (800) 442-1902 WEEKDAYS.
752496-100 Rev. H
© American Standard Inc. 2003 All product names listed herein are trademarks of American Standard Inc. unless otherwise noted.
INSTALLATION AND FRAMING INSTRUCTIONS
The variety of installations possible for this whirlpool may require framing procedures other than those shown. Locate studs as required. Ensure roughing-in dimensions are proper, plumb and square. Provisions must be made in all installations for an access opening for servicing the pump and controls. It is strongly recommended that an additional opening be provided for access to the drain components.
NOTE: The apron should not be used as the primary access opening.
1. Position the whirlpool into the installation opening and level the deck, shimming the integral support feet as necessary. Mark the final position of the underside of the deck by tracing a line on to the studs (see Figure 1).
2. Remove the whirlpool and attach a 2 x 4 stringer to the studs, with the top of the stringer touching the traced line.
3. Install drain components to the whirlpool following the manufacturers instructions. Before replacing your whirlpool for final
installation, be certain that an opening has been provided in the sub-floor for the drain. See the roughing-in drawing for suggested opening size and location dimensions.
4. Replace whirlpool and re-shim the integral support feet, shimming the entire length of the support feet. Secure the shims
using construction adhesive, silicone, mortar or equivalent materials. While not a necessity, the use of a foundation base consisting of cement (e.g. Sakrete), mortar, or grout will help provide a solid and secure installation.
FIG. 1
464mm
(18-1/4)
TYPICAL RECESS INSTALLATION
TILE
WALLBOARD
TILE
BEAD
STRIP
SEALANT
BATH
ADHESIVE
LEVELING
STRINGER
NOTE: Tile bead kit not included and must be purchased separately.
TYPICAL PIER TYPE INSTALLATION
AS DESIRED
870mm
464mm
(18-1/4)
(34-1/4)
CUTOUT
1791mm
(70-1/2)
CUTOUT
464mm
(18-1/4)
1832mm
(72-1/8)
UNLESS AN ACCESS OPENING OF AT LEAST
12" X 24" (305 X 610MM) IS PROVIDED,
WARRANTY SERVICE WILL NOT BE PERFORMED.
870mm
(34-1/4)
908mm
(35-3/4)
TUB WIDTH
LEVELING STRINGERS
WHIRLPOOL ONLY:
610mm
(24)
305mm
(12)
752496-100 Rev. H (2)
LEVELING SURFACE
WARRANTY SERVICE WILL NOT BE PERFORMED.
AS DESIRED
WATERPROOF SEALANT
BATH
UNLESS AN ACCESS OPENING OF AT LEAST
12" X 24" (305 X 610MM) IS PROVIDED,
WHIRLPOOL ONLY:
ACCESS PANEL
610mm
(24)
305mm
(12)
Loading...
+ 2 hidden pages