CADET™
5' x 42"
HIGH GLOSS ACRYLIC
SHOWN LESS ALL FITTINGS
305 mm
RECOMMENDED FITTING LOCATION
(3/4)
(12)
229 mm
(9)
CUTOUT IN FLOOR
FOR DRAIN
57 mm
(2-1/4)
C/L OF DRAIN
C/L OF
OVERFLOW
38 mm
(1-1/2)
76mm
(3)
502 mm
(19-3/4)
ROUGH
FLOOR
INTEGRAL
SUPPORT
FEET
1-1/2 O.D.TAILPIECE
60 x 42 x 19-3/4 In.(1524 x 1067 x 502mm)
235 mm
(9-1/4)
19 mm
FINISHED
WALL
SEE FITTING
SPECS FOR
DIMENSIONS
1067mm
(42)
533mm
(21)
C/L OF
SUPPLIES
OPTIONAL TO
FINISHED FLOOR
USUALLY BETWEEN
1651 & 1981mm
(65 & 78)
GENERAL SPECIFICATIONS FOR 2772 WHIRLPOOL
INSTALLED SIZE
WEIGHT
WEIGHT w/WATER
GAL. TO OVERFLOW
MIN. OPERATING GAL.
BATHING WELL AT SUMP
BATHING WELL AT RIM
WATER DEPTH TO OVERFLOW
FLOOR LOADING
(PROJECTED AREA)
PTS.
CUBE (FT3)
WHIRLPOOL ELECTRICAL SPECIFICATIONS
2772.XXXW SERIES
WHIRLPOOL/BATHING POOL
INSTALLATION INSTRUCTIONS
PROVIDE ACCESS TO PUMP FOR
SERVICING ON ALL INSTALLATIONS
1524mm
(60)
76 X 330mm (3 x 13")
FOR PIER OR ISLAND
INSTALLATIONS ONLY
PUMP
(8) JETS
1-1/2 N.P.T.M.
(2) AIR VALVES
ALT. FITTING LOCATION
C/L OF
SHOWER ARM
C/L OF
VALVES
305mm
(12)
102 mm
(4)
THREADS
40 x 26 In. (1016 x 660 mm)
52 x 32-1/2 In. 1321 x 826 mm)
37 Lbs./Sq. Ft. (182 Kgs/Sq. m.)
C/L OF
SPOUT
SAFE-T-HEATER
REMOVABLE
BLANK
70 mm
(2-3/4)
117 Lbs. (53 Kg.)
642 Lbs. (289 Kg.)
13-1/4 In. (337 mm)
1.6 HP, 9.7 AMPS, 120V.SYSTEM I PUMP
OUTLINE OF CUTOUT
1486mm x 1029mm
(58-1/2 X 40-1/2)
■ LEVELING
STRINGER
NOT FOR
SUPPORT
464 mm
(18-1/4)
117 mm
(4-5/8)
63 Gal. 239 L.)
54 Gal. (204 L.)
27.8
45.4
ON/OFF
SWITCH
THANK YOU...
for selecting an American Standard bath. Your new
bath is shipped to you after careful inspection. The
whirlpool version is completely assembled with pump,
motor, and system piping. All you need to finish the
installation are your selected fittings and electrical
connections for a whirlpool.
To insure maximum performance and pleasure from
this product, please follow the instructions and
cautions.
List of Optional Components (not included):
• Safe-T-Heater 9075.120*
• Tile Bead Kit 751755-100*
• Apron Kit*
* see your American Standard Distributor
List of Required Components (not included):
• Drain 1583.470* • Bath Filler*
* see your American Standard Distributor
List of Required Tools and Supplies:
Tools
• Level
• Tape Measure
• Pipe Wrench
• Slip Joint Pliers
• Screw Driver
• Standard
Woodworking Tools
• Personal Safety
Equipment
• Caulking Gun
Supplies
• Nails
• Putty
• Caulking (waterproof)
• 1 x 3 or 2 x 2
Stringers
• Drop Cloth
• 15 amp GFI
Outlet
• Cement, Plaster,
Grout
GENERAL INSTALLATION INFORMATION
Carefully uncrate and inspect your new bath for any shipping damage. If such damage is found, report it to your vendor
immediately.
After inspection and during installation, protect the bath from construction damage. After installation, and before
enclosing with wallboard, tile, etc., water test the unit and check for leaks.
Do not make modifications to the whirlpool system or remove pump from factory mounting. This could adversely affect
the safety and performance of the whirlpool and void the warranty. Do not handle or move the whirlpool by the pump,
motor, or piping system.
Fittings (bath filler, shower arm, etc.) are not provided with the bath and must be ordered separately. Framing and
enclosing materials are provided by others. Check for availability of optional American Standard wall tiling bead
(required for recess installations).
Protect all finished surfaces of the whirlpool during construction and installation using a drop cloth.
WARNING! Do not lift whirlpool by the piping harness at any time.
FOR AFTER-SALES SERVICE CALL 1 (800) 442-1902 WEEKDAYS.
752501-100 Rev. J
© American Standard Inc. 2005
All product names listed herein are trademarks
of American Standard Inc. unless otherwise noted.
INSTALLATION AND FRAMING INSTRUCTIONS
The variety of installations possible for this whirlpool may require framing procedures other than those shown. Locate studs
as required. Ensure roughing-in dimensions are proper, plumb and square. Provisions must be made in all installations for an
access opening for servicing the pump and controls. It is strongly recommended that an additional opening be provided for
access to the drain components.
NOTE: The apron should not be used as the primary access opening.
1. Position the whirlpool into the installation opening and level the deck, shimming the integral support feet as necessary.
Mark the final position of the underside of the deck by tracing a line on to the studs (see Figure 1).
2. Remove the whirlpool and attach a 2 x 4 stringer to the studs, with the top of the stringer touching the traced line.
It may be necessary to notch stringer near the SAFETY-T-HEATER blank to avoid interference, should heater be
installed at a later date.
3. Install drain components to the whirlpool following the manufacturers instructions. Before replacing your whirlpool for final
installation, be certain that an opening has been provided in the sub-floor for the drain. See the roughing-in drawing for
suggested opening size and location dimensions.
4. Replace whirlpool and re-shim the integral support feet, shimming the entire length of the support feet. Secure the shims
using construction adhesive, silicone, mortar or equivalent materials. While not a necessity, the use of a foundation base
consisting of cement (e.g. Sakrete), mortar, or grout will help provide a solid and secure installation.
FIG. 1
464mm
(18-1/4)
TYPICAL RECESS INSTALLATION
NOTCH STINGER AT
HEATER BLANK
SEE NOTE 2 ABOVE
TILE
WALLBOARD
TILE
BEAD
STRIP
SEALANT
BATH
ADHESIVE
LEVELING
STRINGER
NOTE: Tile bead kit not included and must be
purchased separately.
TYPICAL PIER TYPE INSTALLATION
AS DESIRED
1029mm
CUTOUT
464mm
(18-1/4)
(40-1/2)
NOTCH STINGER AT
HEATER BLANK
SEE NOTE 2 ABOVE
1486mm
(58-1/2)
CUTOUT
464mm
(18-1/4)
1527mm
(60-1/8)
UNLESS AN ACCESS OPENING OF AT LEAST
12" X 24" (305 X 610MM) IS PROVIDED,
WARRANTY SERVICE WILL NOT BE PERFORMED.
1029mm
(40-1/2)
1067mm
(42)
TUB WIDTH
LEVELING
STRINGERS
WHIRLPOOL ONLY:
610mm
(24)
305mm
(12)
752501-100 Rev. J (2)
LEVELING
SURFACE
WARRANTY SERVICE WILL NOT BE PERFORMED.
AS DESIRED
WATERPROOF
SEALANT
BATH
UNLESS AN ACCESS OPENING OF AT LEAST
12" X 24" (305 X 610MM) IS PROVIDED,
WHIRLPOOL ONLY:
ACCESS PANEL
610mm
(24)
305mm
(12)