TOWN SQUARE®
5' x 42"™
HIGH GLOSS ACRYLIC
SHOWN LESS ALL FITTINGS
2748.XXXW SERIES
WHIRLPOOL/BATHING POOL
INSTALLATION INSTRUCTIONS
59-1/2"
ON/OFF
SWITCH
14-1/2"
(368mm)
41-5/8"
(1057mm)
PROVIDE ACCESS
TO PUMP FOR
SERVICE ON ALL
INSTALLATIONS
PUMP
OUTLINE OF
SKID RESISTANT
SURFACE
2"
(51mm)
5-3/4"
(146mm)
3-1/8"
(79mm)
HOLE DRILLING LOCATION FOR AMERICAN STANDARD "TOWN SQUARE"
DECK MOUNT BATH FILLER WITH PERSONAL SHOWER, MODEL #2555.901 ONLY
3/4"
(19mm)
(759mm)
TO END
OF TUB
FOR SPOUT
& VALVES
1-1/2
(38mm)
1-1/2
(38mm)
29-7/8
(759mm)
FLOOR CUTOUT
(127 X 305mm)
C/L OF
OVERFLOW
1-1/2" N.P.T.
THREADS
1-1/2" O.D.
TAILPIECE
2-1/2
(64mm)
4-1/2
(114mm)
29-7/8"
JETS (6)
(1511mm)
5" X 12"
SUCTION
PUMP
SAFE-T-HEATER
REMOVABLE
BLANK
C/L
4-1/2
(114mm)5(127mm)
INTEGRAL
FITTING DECK
2-1/2" X 14"
(64 X 356mm)
LEVELING STRINGER
(NOT FOR SUPPORT)
ROUGH
FLOOR
INTEGRAL
FEET
SUPPORT
DRAIN
FITTINGS
DECK
(38mm)
OUTLINE OF CUTOUT
58-1/4" X 40-1/4"
(1480 X 1022mm)
FOR HAND
SPRAY
EDGE OF
FITTINGS
1-1/2
DECK
(76mm)
21"
(533mm)
3"
3/4"
(19mm)
23"
(584mm)
5-1/4"
(133mm)
C/L OF
DRAIN
OUTLET
EDGE OF
FLOOR
CUTOUT
THANK YOU...
for selecting an American Standard bath. Your
new bath is shipped to you after careful
inspection. The whirlpool version is completely
assembled with pump, motor, and system piping.
All you need to finish the installation are your
selected fittings and electrical connections for a
whirlpool. To insure maximum performance and
pleasure from this product, please follow the
instructions and cautions.
List of Optional Components (not included):
• Tile Bead Kit (P/N 751755-200)
• 5 Foot Apron 9460.018
• Safe-T-Heater 9075.120*
List of Required Components (not included):
• Drain 1594.170
• Bath Filler
List of Required Tools and Supplies:
Tools
• Level
• Tape Measure
• Pipe Wrench
• Slip Joint Pliers
• Screw Driver
• Standard
Woodworking Tools
• Personal Safety
Equipment
• Caulking Gun
INSTALLED SIZE
WEIGHT
WEIGHT w/WATER
GAL. TO OVERFLOW
WHIRLPOOL MIN. OPERATING VOL.
BATHING WELL AT SUMP
BATHING WELL AT RIM
WATER DEPTH TO OVERFLOW
FLOOR LOADING
(PROJECTED AREA)
PTS.
CUBE (FT3)
GENERAL SPECIFICATIONS FOR 2742 WHIRLPOOL
71-1/2 x 41-3/4 x 22 In. (1816 x 1060 x 559mm)
WHIRLPOOL ELECTRICAL SPECIFICATIONS
Supplies
• Nails
• Putty
• Caulking (waterproof)
• 1 x 3 or 2 x 2
Stringers
• Drop Cloth
• 15 amp GFI
Outlet
• Cement, Plaster,
Grout
115 Lbs. (52 Kg.)
690 Lbs. (313 Kg.)
69 Gal. (261 L)
41 x 21-1/2 In. (1041 x 546mm)
62 x 31-1/2 In. (1574 x 800mm)
33 Lbs./Sq.Ft. (163 Kgs./Sq.m)
2.1 HP, 14.4 AMPS ,120V.WHIRLPOOL PUMP
60 Gal. (227 L)
14-1/4 In. (362mm)
27.8
55.7
GENERAL INSTALLATION INFORMATION
Carefully uncrate and inspect your new bath for any shipping damage. If such damage is found, report it to your vendor
immediately. After inspection and during installation, protect the bath from construction damage. After installation, and
before enclosing with wallboard, tile, etc., water test the unit and check for leaks.
Do not make modifications to the whirlpool system or remove pump from factory mounting. This could adversely affect the
safety and performance of the whirlpool and void the warranty. Do not handle or move the whirlpool by the pump, motor, or
piping system.
Fittings (bath filler, shower arm, etc.) are not provided with the bath and must be ordered separately. Framing and enclosing
materials are provided by others. Check for availability of optional American Standard wall tiling bead (required for recess
installations). If installing American Standard 2555.901 "Town Square" deck mount bath filler, please refer to hole
drilling location above.
Protect all finished surfaces of the whirlpool during construction and installation using a drop cloth.
WARNING! Do not lift whirlpool by the piping harness at any time.
FOR AFTER-SALES SERVICE CALL 1 (800) 442-1902 WEEKDAYS.
753026-100 Rev. G
© American Standard Inc. 2007
All product names listed herein are trademarks
of American Standard Inc. unless otherwise noted.
INSTALLATION AND FRAMING INSTRUCTIONS
The variety of installations possible for this whirlpool may require framing procedures other than those shown. Locate studs as
required. Ensure roughing-in dimensions are proper, plumb and square. Provisions must be made in all installations for an
access opening for servicing the pump, blower and controls. It is strongly recommended that an additional opening be provided
for access to the drain components.
NOTE: The apron should not be used as the primary access opening.
1. Position the whirlpool into the installation opening and level the deck, shimming the integral support feet as necessary.
Mark the final position of the underside of the deck by tracing a line on to the studs (see Figure 1).
2. Remove the whirlpool and attach a 2 x 4 stringer to the studs, with the top of the stringer touching the traced line.
The rim of the bath MUST NOT support weight.
3. Install drain components to the whirlpool following the manufacturers instructions. Before replacing your whirlpool for final
installation, be certain that an opening has been provided in the sub-floor for the drain. See the roughing-in drawing for
suggested opening size and location dimensions.
4. Replace whirlpool and re-shim the integral support feet, shimming the entire length of the support feet. Secure the shims
using construction adhesive, silicone, mortar or equivalent materials. While not a necessity, the use of a foundation base
consisting of cement (e.g. Sakrete), mortar, or grout will help provide a solid and secure installation.
FIG. 1
533mm
(21)
TYPICAL RECESS INSTALLATION
TILE
WALLBOARD
TILE
BEAD
STRIP
SEALANT
BATH
ADHESIVE
LEVELING
STRINGER
NOTE: Tile bead kit not included and must be
purchased separately.
TYPICAL PIER TYPE INSTALLATION
AS DESIRED
533mm
(21)
1019mm
(40-1/8)
CUTOUT
1473mm
(58)
CUTOUT
533mm
(21)
1518mm
(59-3/4)
UNLESS AN ACCESS OPENING OF AT LEAST
12" X 24" (305 X 610MM) IS PROVIDED,
WARRANTY SERVICE WILL NOT BE PERFORMED.
753026-100 Rev. G
0m
1
10
-
39
(
TUB
m
)
/4
3
1060mm
-3/4)
(41
WIDTH
LEVELING
STRINGERS
610 mm
(24)
305mm
(12)
AS
DESIRED
LEVELING
SURFACE
WATERPROOF
SEALANT
ACCESS PANEL
BATH
UNLESS AN ACCESS OPENING OF AT LEAST
12" X 24" (305 X 610MM) IS PROVIDED,
WARRANTY SERVICE WILL NOT BE PERFORMED.
(2)
SPIC AND SPAN® IS A REGISTERED TRADEMARK OF PROCTER & GAMBLE
610mm
(24)
305mm
(12)