American Standard 2703.XXXW, 2705.XXXW User Manual

ELLISSE BUILT-IN™
2703.XXXW
2705.XXXW
HIGH GLOSS ACRYLIC SHOWN LESS ALL FITTINGS
SEE FITTING
305mm
(12) OPT.
TOP
OF
DECK
546mm
(21-1/2)
SPECS FOR
DIMENSION
(15-1/4)
813mm
(32)
SUPPLIES
95mm (3-3/4)
387mm
C/L OF
102mm (4)
ROUGH FLOOR
19mm (3/4)
C/L OF DRAIN OUTLET
C/L OF
SHOWER ARM
SAFE-T-HEATER
REMOVABLE BLANK
51mm (2)
C/L OF
OVERFLOW
INTEGRAL FEET
1-1/2 N.P.T.
THREADS
1-1/2 O.D.
TAILPIECE
51mm (2)
GENERAL SPECIFICATIONS FOR 2703/5 WHIRLPOOL
INSTALLED SIZE WEIGHT WEIGHT w/WATER GAL. TO OVERFLOW WHIRLPOOL MIN. OPERATING VOL. BATHING WELL AT SUMP BATHING WELL AT RIM WATER DEPTH TO OVERFLOW FLOOR LOADING (PROJECTED AREA) PTS. CUBE (FT3)
SYSTEM I PUMP SYSTEM II PUMP
WHIRLPOOL ELECTRICAL SPECIFICATIONS
SERIES WHIRLPOOL
INSTALLATION INSTRUCTIONS
1524mm
229mm (9)
229x305mm (9x12) FLOOR CUTOUT
ALT. PUMP
LOCATION
60 x 32 x 21-1/2 In. (1524 x 813 x 546mm)
(60)
WATER RETENTION
FINISHED WALL LINE
C/L OF VALVES
C/L OF SPOUT
38mm
(1-1/2)
44-1/2 X 20 In. (1130 mm X 508 mm) 58 X 26-1/4 In. (1473 mm X 667 mm)
FLANGE (3) SIDES
ON/OFF SWITCH
TO PUMP FOR SERVICING
ON ALL INSTALLATIONS
FINISHED WALL
WATER RETENTION FLANGE
LEVELING STRINGER NOT FOR SUPPORT
ROUGH FLOOR
48 Lbs./Sq.Ft. (231 Kgs./Sq.m)
533mm
83mm (3-1/4)
14-1/2 In. (368 mm)
1.6 HP, 9.7 AMPS, 120V.
2.1 HP, 15.6 AMPS, 120V.
PUMP
PROVIDE ACCESS
1651-1981mm
(65-78)
OPTIONAL
38mm (1-1/2)
UNDERSIDE OF DECK
(21)
141 Lbs. (63 Kg.)
643 Lbs. (292 Kg.)
60 Gal. (277 L) 50 Gal. (189 L)
20.8
35.3
THANK YOU...
for selecting an American Standard bath. Your new bath is shipped to you after careful inspection. The whirlpool version is completely assembled with pump, motor, and system piping. All you need to finish the installation are your selected fittings and electrical connections for a whirlpool.
To insure maximum performance and pleasure from this product, please follow the instructions and cautions.
List of Optional Components (not included):
• Apron Kit*
• Safe-T-Heater 9075.120* * see your American Standard Distributor
List of Required Components (not included):
• Drain 1583.470* • Bath Filler* * see your American Standard Distributor
List of Required Tools and Supplies: Tools
• Level
• Tape Measure
• Pipe Wrench
• Slip Joint Pliers
• Screw Driver
• Standard Woodworking Tools
• Personal Safety Equipment
• Caulking Gun
GENERAL INSTALLATION INFORMATION
Carefully uncrate and inspect your new bath for any shipping damage. If such damage is found, report it to your vendor immediately.
After inspection and during installation, protect the bath from construction damage. After installation, and before enclosing with wallboard, tile, etc., water test the unit and check for leaks.
If a whirlpool, do not make modifications to the whirlpool system or remove pump from factory mounting. This could adversely affect the safety and performance of the whirlpool and void the warranty. Do not handle or move the whirlpool by the pump, motor, or piping system.
Fittings (bath filler, shower arm, etc.) are not provided with the bath and must be ordered separately. Framing and enclosing materials are provided by others. Check for availability of optional American Standard wall tiling bead (required for recess installations).
Protect all finished surfaces of the whirlpool during construction and installation using a drop cloth.
Supplies
• Nails
• Putty
• Caulking (waterproof)
• 1 x 3 or 2 x 2 Stringers
• Drop Cloth
• 15 or 20 amp GFCI Outlet
• Cement, Plaster, Grout
752352-100 REV. H
WARNING! Do not lift whirlpool by the piping har­ness at any time.
© American Standard Inc. 2003 All product names listed herein are trademarks of American Standard Inc. unless otherwise noted.
FRAMING AND INSTALLATION
BATH MAY ONLY BE INSTALLED ABOVE THE FLOOR LINE IN A RECESS TYPE INSTALLATION, AS SHOWN IN RECESS INSTALLATION DIAGRAM.
THE FOLLOWING PROCEDURE MUST BE USED FOR ALL INSTALLATIONS: STRINGER OR PIER HEIGHT SHOULD BE AS INDICATED. THE SUMP OF THE BATH IS SUPPORTED BY INTEGRAL FEET AND NO ADDITIONAL SUMP SUPPORT IS REQUIRED. ONCE THE BATH IS IN PLACE, THE FEET SHOULD BE SHIMMED ACCORDINGLY, SO THAT THE RIM OF THE BATH CONTACTS THE STRINGER OR PIER BUT SUPPORTS NO WEIGHT. ANY FINISH MATERIAL, SUCH AS TILE OR WALL BOARD, MUST BE SELF-SUPPORTING IF IT CONTACTS THE RIM OF THE BATH.
LOCATE STUDS AS REQUIRED. INSURE ROUGH DIMENSIONS ARE PROPER, PLUMB AND SQUARE. FOR REAR MOTOR
MOUNT WHIRLPOOLS, PROVISION MUST BE MADE IN ALL INSTALLATIONS FOR AN ACCESS OPENING FOR SERVICING PUMP AND CONTROLS.
TYPICAL RECESS INSTALLATION STUD FLANGE BRACKET
INSTALLATION
BATH FLANGE
BATH
DRYWALL SCREW
STUD FLANGE BRACKET
STUD
2 X 4
STRINGER
SUPPORT
533mm
(21)
WALL BOARD
ADHESIVE
1527mm
TILE
SEALANT
(60-1/8)
775mm
(30)
813mm
TUB WIDTH
1 X 3 X 8 LEVELING STRINGER
1 X 3 LEVELING STRINGER
305mm
(12)
(32)
610mm
(24)
BATH
LEVELING STRINGER
WHIRLPOOL ONLY: UNLESS AN ACCESS OPENING OF AT LEAST 305mm X 610mm(12" X 24") IS PROVIDED, WARRANTY SERVICE WILL NOT BE PERFORMED.
SECURE THE BATH TO THE STUDS AS SHOWN USING THE SCREWS AND BRACKETS PROVIDED ­SEE STUD FLANGE BRACKET INSTALLATION
STUD FLANGE BRACKET INSTALLATION
PROVIDED WITH THE BATH IS A PACKAGE OF (4) FOUR STUD FLANGE BRACKETS AND (8) EIGHT SCREWS. INSTALL BRACKETS AND SCREWS AS SHOWN IN WALL BRACKET INSTALLATION DETAIL. TWO BRACKETS SHOULD BE LOCATED EVENLY ACROSS THE BACK TILE FLANGE AND INSTALL ONE BRACKET ON EACH END OF THE BATH, TOWARDS THE FRONT END OF THE TILE FLANGE. THIS WILL ALLOW TILE FLANGE TO BE HELD SECURELY AGAINST STUDWALL OF RECESS INSTALLATION.
752352-100 REV. H (2)
SPIC AND SPAN® IS A REGISTERED TRADEMARK OF PROCTER & GAMBLE
Loading...