American Standard 2696.102, 2696.202 User Manual

BARRIER FREE
SPECTRA™ 5-1/2' CAST IRON TUB
SUP PO RT
FEE T
ROU GH
FLO OR
FIN IS HED
WAL L
229 x 30 5m m
9" X 12" H OLE I N S UB FL OO R
FOR B ELO W FLO OR RO UG H
813 mm
32"
168 2m m
66- 1/ 4"
384 mm 15- 1/ 8"
FIN IS HED WAL L
FIN IS HED WAL L
73m m 2-7 /8 "
FINISHED WALL
194 mm
7-5 /8 "
406 mm
16"
64m m 2-1 /2 "
DIA .
18m m 11/ 16 "
13m m
1/2 "
76m m 3"
102 mm
4"
STD. 1-1/2
DRAIN OUTLET
32m m 1-1 /4 "
GENERAL SPECIFICATIONS FOR 2696 BATHING POOL
66-1/4 x 32 x 16 In. (1682 x 813 x 406mm)
430 Lbs. (195 Kg.) 870 Lbs. (395 Kg.)
53 Gal. (200 L)
45 x 19-3/8 In. (1143 x 492mm)
58 x 26 In. (1473 x 660mm)
11 In. (279mm)
60 Lbs./Sq.Ft. (293 Kgs./Sq.m)
20.5
INSTAL LED SIZE WEIGHT WEIGHT w/WATER GAL. T O OVERFLOW BATHIN G WELL AT SUMP BATHIN G WELL AT RIM WATER DEPTH TO OVERFLOW FLOOR LOADING (PROJE CTED AREA) CUBE ( FT3)
MEETS THE AMERICANS WITH DISABILITIES ACT GUIDELINES AND ANSI A117.1 REQUIREMENTS FOR ACCESSIBLE AND USEABLE BUILDING FACILITIES-CHECK LOCAL CODES. INSTALL WITH SEAT AT HEAD END.
2696.102 Right hand outlet2696.202 Left hand outlet
Product Features:
• Enameled cast iron construction
• One-piece bath
• Integral apron
• Comfortable lumbar support
• End drain outlet
• Full slip-resistant pattern
Nominal Dimensions:
66-1/4" x 32" x 16" (1682 x 813 x 406mm)
Compliance Certications ­Meets or Exceeds the Following Specications:
• ASME A112.19.1 for Cast Iron Plumbing Fixtures
• ASTM F-462 for Slip-resistant Bathing Facilities
• CAN / CSA B45 Series
SPECTRA™
5-1/2' TUB
ENAMELED CAST IRON
To Be Specied:
Color: Bath Faucet*: Faucet Finish: Drain: 1583.470
* See faucet section for additional models available
© 2008 AS America Inc.
NOTES:
LEFT HAND OUTLET SHOWN, RIGHT HAND REVERSE DIMENSIONS (2696.102). PROVIDE SUITABLE REINFORCEMENT FOR ALL WALL SUPPORTS. FITTINGS NOT INCLUDED AND MUST BE ORDERED SEPARATELY.
REFER TO INSTALLATION INSTRUCTIONS SUPPLIED WITH BATH.
IMPORTANT: Dimensions of xtures are nominal and may vary within the range of tolerances established by ANSI Standard A112.19.1. These measurements are subject to change or cancellation. No responsibility is assumed for use of superseded or voided leaet.
H159
Revised 02/07
Loading...