American Standard 2645 User Manual

Page 1
SCALA™ 5-1/2
2645 SERIES
HIGH GLOSS ACRYLIC SHOWN LESS ALL FITTINGS
302mm (11-7/8)
914mm
(36)
419mm
(18)
210mm
(8-1/4)
44mm (1-3/4)
C/L OF DRAIN
INTEGRAL
FEET SUPPORT
1-1/2 N.P.T.M. THREADS
1-1/2 O.D. TAILPIECE
GENERAL SPECIFICATIONS FOR 2645 WHIRLPOOL
INSTALLED SIZE WEIGHT WEIGHT w/WATER GAL. TO OVERFLOW WHIRLPOOL MIN. OPERATING VOL. BATHING WELL AT SUMP BATHING WELL AT RIM WATER DEPTH TO OVERFLOW FLOOR LOADING (PROJECTED AREA) PTS.
CUBE (FT3)
SYSTEM I PUMP
WHIRLPOOL ELECTRICAL SPECIFICATIONS
WHIRLPOOL/BATHING POOL
INSTALLATION INSTRUCTIONS
RECOMMENDED FITTING LOCATION 64 X 330mm (2-1/2" x 13")
HAND SHOWER LOCATION
51mm (2)
229mm X 305mm (9 X 12) CUTOUT FOR DRAIN
LEVELING STRINGER (NOT FOR SUPPORT)
66 x 36 x 19-3/4 In. (1676 x 914 x 502mm)
OUTLINE OF CUTOUT
1626mm X 864mm
102mm (4)
44mm (1-3/4)
457mm
(3-5/8)
595 Lbs. (268 Kg.)
46 x 24 In. (1168 x 610mm)
62 X 31-1/2 In. (1575 x 800mm)
36 Lbs./Sq.Ft. (175 Kgs/Sq.m)
13-1/4 In. (337mm)
1.1 HP, 9.9 AMPS,120V.
1676mm
(66)
(64 X 34)
PUMP
PROVIDE ACCESS
TO PUMP FOR
SERVICING ON ALL
INSTALLATIONS
38mm
(1-1/2)
464mm
(18-1/4)
95 Lbs. (43 Kg.)
55 Gal. (208 L)
502mm
(19-3/4)
60 Gal. (227 L)
25.6
45.1
6mm (1/4) TYP.
25mm (1)
ON/OFF
SWITCH
TYP.
THANK YOU...
for selecting an American Standard bath. Your new bath is shipped to you after careful inspection. The whirlpool version is completely assembled with pump, motor, and system piping. All you need to finish the installation are your selected fittings and electrical connections for a whirlpool.
To insure maximum performance and pleasure from this product, please follow the instructions and cautions.
List of Optional Components (not included):
• Apron Kit* * see your American Standard Distributor
List of Required Components (not included):
• Drain 1583.470* • Bath Filler* * see your American Standard Distributor
List of Required Tools and Supplies: Tools
• Level
• Tape Measure
• Pipe Wrench
• Slip Joint Pliers
• Screw Driver
• Standard Woodworking Tools
• Personal Safety Equipment
• Caulking Gun
GENERAL INSTALLATION INFORMATION
Carefully uncrate and inspect your new bath for any shipping damage. If such damage is found, report it to your vendor immediately.
After inspection and during installation, protect the bath from construction damage. After installation, and before enclosing with wallboard, tile, etc., water test the unit and check for leaks.
If a whirlpool, do not make modifications to the whirlpool system or remove pump from factory mounting. This could adversely affect the safety and performance of the whirlpool and void the warranty. Do not handle or move the whirlpool by the pump, motor, or piping system.
Fittings (bath filler, shower arm, etc.) are not provided with the bath and must be ordered separately. Framing and enclosing materials are provided by others. Check for availability of optional American Standard wall tiling bead (required for recess installations).
Protect all finished surfaces of the whirlpool during construction and installation using a drop cloth.
Supplies
• Nails
• Putty
• Caulking (waterproof)
• 1 x 3 or 2 x 2 Stringers
• Drop Cloth
• 15 amp GFCI Outlet
• Cement, Plaster, Grout
OR AFTER-SALES SERVICE CALL 1 (800) 442-1902 WEEKDAYS.
750733-100 Rev. F
WARNING! Do not lift whirlpool by the piping har­ness at any time.
© American Standard Inc. 2003 All product names listed herein are trademarks
Page 2
FRAMING AND INSTALLATION
THE VARIETY OF INSTALLATIONS POSSIBLE FOR THIS BATH MAY REQUIRE FRAMING PROCEDURES OTHER THAN THOSE SHOWN.
LOCATE STUDS AS REQUIRED. INSURE ROUGH DIMENSIONS ARE PROPER, PLUMB AND SQUARE. FOR WHIRLPOOLS, PROVISION MUST
BE MADE IN ALL INSTALLATIONS FOR AN ACCESS OPENING FOR SERVICING PUMP AND CONTROLS.
THE FOLLOWING PROCEDURE MUST BE USED FOR ALL INSTALLATIONS: STRINGER OR PIER HEIGHT SHOULD BE AS INDICATED. THE SUMP OF THE BATH IS SUPPORTED BY INTEGRAL FEET AND NO ADDITIONAL SUMP SUPPORT IS REQUIRED. ONCE THE BATH IS IN PLACE, THE FEET SHOULD BE SHIMMED ACCORDINGLY, SO THAT THE RIM OF THE BATH CONTACTS THE STRINGER OR PIER BUT SUPPORTS NO WEIGHT. ANY FINISH MATERIAL, SUCH AS TILE OR WALL BOARD, MUST BE SELF-SUPPORTING IF IT CONTACTS THE RIM OF THE BATH.
SUGGESTED INSTALLATION
METHODS
MOUNTING SURFACE
WATERPROOF SEALANT
BATH
TYPICAL PIER TYPE INSTALLATION
AS DESIRED
34 (864mm) CUTOUT
18-1/4
(464mm)
AS DESIRED
ACCESS PANEL
WHIRLPOOL ONLY: UNLESS AN ACCESS OPENING OF AT LEAST 12" X 24" (305 X 610 mm) IS PROVIDED, WARRANTY SERVICE WILL NOT BE PERFORMED.
64
(1626 mm)
CUTOUT
(610 mm)
(305 mm)
24
12
50733-100 Rev. F (2)
SPIC AND SPAN® IS A REGISTERED TRADEMARK OF PROCTER & GAMBLE
Page 3
ELECTRICAL INSTALLATION INSTRUCTIONS
All wiring must be performed by a licensed electrician in accordance with the national electrical code and all other applicable codes.
WARNING:
When using electrical products, basic precautions should always be observed, including the following:
1. DANGER: RISK OF ELECTRIC SHOCK
Connect only to a circuit protected by a ground-fault circuit interrupter.
2. Grounding is required. The unit should be installed by a licensed electrician and grounded.
3. Install to permit access for servicing.
4. All building materials and wiring should be routed away from the pump body and heater (if equipped).
The whirlpool should be installed on a 120 vac, 15 amp dedicated circuit. The circuit should be hard-wired from the electrical power supply panel. The circuit must be a three (3) wire circuit from the electrical supply panel. A grounded neutral wire and a third wire, earth ground, are essential.
ELECTRICAL INSTALLATION
SEPERATE
15 AMP
GFCI OUTLET
120 VAC
WHITE
GND.
WHIRLPOOL MOUNTED
AIR SWITCH OR
WALL TIMER
BLACK
PUMP/MOTOR
ELECTRICAL DIAGRAM
READ AND FOLLOW ALL INSTRUCTIONS
750733-100 Rev. F
(3)
Page 4
WIRE SELECTION GUIDE
Maximum distance from
fusebox to motor
The sizes shown on this
chart are recommendations
50' 100'
Motor High
Performance
1.1
DRAIN CONNECTION AND SYSTEM TEST
Using recommended drain opening, connect whirlpool drain to waste line. Tighten all drain joints securely. Check the pump couplings and make sure they are hand-tight. Clean the whirlpool and fill with water to a point 2" above the top of the highest jet. Recheck the pump couplings and make certain that they are not leaking. (Although the pump couplings are factory tightened and inspected, some loosening may have occured during transit.) Make sure the whirlpool is connected to the electrical supply and turn the whirlpool on. Check for leaks around all piping connections while the whirlpool is running.
POST INSTALLATION CLEAN-UP
12 12 10 8
115V Power Line
150' 200'
for copper conductors
only. Always follow
local and national
electrical codes
Remove all construction debris from bath. Tile grout can be removed with a wooden popsicle stick or tongue depressor. Do not use wire brushes or any other metal implement on bath surface.
Post installation clean-up generally can be completed using warm water and liquid dishwashing detergent. Stubborn dirt or stains may be removed using granular Spic and Span® mixed with water.
Painter's naphtha can be used to remove excess adhesives and/or wet oil-base paint.
HARSH CHEMICALS SHOULD NEVER BE USED ON ACRYLIC SURFACES.
Abrasive cleaners must not be used since they will scratch and dull the surface. Dulled areas can be restored by rubbing with a white automotive-type polishing compound and waxing with a liquid wax.
750733-100 Rev. F
(4)
SPIC AND SPAN® IS A REGISTERED TRADEMARK OF PROCTER & GAMBLE
Loading...