4
6
14
5
SLOT
MOUNTING SURFACE
Turn off hot and cold water supplies before beginning.
Insert SPOUT (1) and CABLE CONNECTOR (14) through center hole, making sure SEAL WASHER (2) is properly seated in SPOUT BASE (3).
Assemble RUBBER WASHER (4), BRASS WASHER (5) and LOCKNUT (6) onto SPOUT SHANK (7) from under side of sink . Make sure SPOUT (1) is centered in the mounting hole and the slot in the BRASS WASHER (5) faces toward the rear of the sink.
Tighten LOCKNUT (6) firmly. Fig. A.
Tighten LOCKNUT (11) with WRENCH (8) (supplied) to secure VALVE BODY (13). Repeat above steps for opposite VALVE BODY (13A).
Install LOCKNUT (11) and RUBBER WASHER (12) onto VALVE BODY (13). From under side of mounting surface, install VALVE BODY (13) through valve mounting holes. Threads of VALVE BODY (13) should extent at least 5/16 of a inch above mounting surface top. Fig. B. Thread DECK ADAPTER (10) onto VALVE BODY (13) until snug against internal stop. If necessary, adjust LOCKNUT (11).
1
1A
Certified to comply with ANSI A112.18.1
Installation
Instructions
Spread Lavatory Faucet
with Speed Connect™ Drain
INSTALL SPOUT
INSTALL VALVE BODY
1
2
1
8
10
9
12
11
13
13a
10
9
12
11
3
Place RUBBER RING (9) into DECK ADAPTER (10).
13
5/16'' MIN.
7
Adjustable Wrench Screwdriver Channel Locks
Recommended tools
Tubing Cutter
Fig. A.
Fig. B.
1
M 9 6 8 7 8 7 R e v. 1 . 3
2555.801
TOWNSQUARE
1
2
DRAIN OUTLET
1
3
4
Congratulations on purchasing your American Standard faucet with Speed Connect drain, a feature found only on American Standard faucets.
*Your new American Standard faucet is designed to work only with the Speed Connect drain.
To ensure that your installation proceeds smoothly-please read these instructions carefully before you begin.
Speed Connect™ Drain*
• Fewer parts, installs in less time
• Never needs adjustment
• Guaranteed to seal properly the first time, every time.
M 9 6 8 7 8 7 R e v. 1 . 3 M 9 6 8 7 8 7 R e v. 1 . 3 M 9 6 8 7 8 7 R e v. 1 . 3
Thread FLANGE (1) counter-clockwise and remove FLANGE (1) and FOAM GASKET (2) from drain body. Fig. A.
Thread LOCKNUT (3) clock-wise to bottom of drain body. Push GASKET (4) down against LOCKNUT (3). Fig. B.
POP-UP DRAIN
Tighten TAILPIECE (4) on DRAIN BODY before installing DRAIN BODY. Fig. B.
2
4
3
2
TIGHTEN LOCKNUT
1
REMOVE FLANGE
Remove CLEAR PLASTIC COVER (1).
Remove CARDBOARD SPACER (2) from under DRAIN POP-UP (3).
2
2
3
3
1
1
Tighten LOCKNUT (1) firmly with Adjustable Wrench or Channel Locks.
INSTALL DRAIN FROM BELOW FIXTURE
5
From under side of SINK install DRAIN BODY (1) up through drain outlet.
Note: No plumber’s putty or caulk is required. The CABLE ATTACHMENT POINT (2) must face towards the rear of the SINK.
Install FOAM GASKET (3) and FLANGE (4) onto drain body from above SINK and tighten FLANGE (4) firmly.
4
Fig. A. Fig. B.
Fig. A. Fig. B.
2
DRAIN OUTLET
1
3
4
REAR OF SINK
DRAIN BODY
4
6
1
POP-UP KNOB (1) must be fully down. Fig. B.
FLANGE GASKET AND POP-UP KNOB
DOWN
WHITE FO AM GASKET NOT VISI BLE
DRAIN FLANGE
Fig. A. Fig. B.
Check DRAIN FLANGE in SINK to ensure that WHITE FOAM GASKET (3) is fully compressed and not visible. Fig. A.