American Standard 2555.201 User Manual

Page 1
Certified to comply with ANSI A112.18.1
Installation
Instructions
Centerset Lavator y Faucet with
the Speed Connect™ Drain
Adjustable Wrench Screwdriver Channel Locks
Recommended tools
1
INSTALL FAUCET
SINK OR
MOUNTING
SURFACE
POP-UP CABLE
PUTTY
Turn off hot and cold water supplies before beginning.
Apply a bead of PUTTY along the edge of the underside of the BODY (1). Insert FAUCET (1) and CABLE CONNECTOR (2) through mounting
holes of Sink or mounting surface.
Fig. A.
Assemble LOCKNUTS (3) onto SHANKS (4) from under side of Sink. Hand tighten firmly.
Fig. B.
2
2
4
3
3
4
Turn off hot and cold water supplies before beginning.
CAUTION
(HAND TIGHTEN)
Fig. A.
Fig. B.
1
2555.201
TOWNSQUARE
1
2
DR AI N OUTL ET
1
3
4
M 9 6 8 7 8 6 R e v .1 . 3
Congratulations on purchasing your American Standard faucet with Speed Connect drain, a feature found only on American Standard faucets.
*Your new American Standard faucet is designed to work only with the Speed Connect drain.
To ensure that your installation proceeds smoothly-please read these instructions carefully before you begin.
Speed Connect™ Drain*
• Fewer parts, installs in less time
• Never needs adjustment
• Guaranteed to seal properly the first time, every time.
Page 2
Thread FLANGE (1) counter-clockwise and remove FLANGE (1) and FOAM GASKET (2) from drain body.
Fig. A.
Thread LOCKNUT (3) clock-wise to bottom of drain body. Push GASKET (4) down against LOCKNUT (3).
Fig. B.
POP-UP DRAIN
Tighten TAILPIECE (4) on DRAIN BODY before installing DRAIN BODY.
Fig. B.
6
2
4
3
2
TIGHTEN LOCKNUT
1
REMOVE FLANGE
Remove CLEAR PLASTIC COVER (1).
Remove CARDBOARD SPACER (2) from under DRAIN POP-UP (3).
2
2
3
3
1
1
Tighten LOCKNUT (1) firmly with Adjustable Wrench or Channel Locks.
INSTALL DRAIN FROM BELOW FIXTURE
5
From under side of SINK install DRAIN BODY (1) up through drain outlet.
Note: No plumber’s putty or caulk is required. The CABLE ATTACHMENT POINT (2) must face towards the rear of the SINK.
Install FOAM GASKET (3) and FLANGE (4) onto drain body from above SINK and tighten FLANGE (4) firmly.
4
Fig. A. Fig. B.
Fig. A. Fig. B.
2
DR AI N OUTL ET
1
3
4
POP-UP KNOB (1) must be fully down. Fig. B.
FLANGE GASKET AND POP-UP KNOB
WHITE FOAM GASKE T NOT VISI BLE
DR AIN FLANG E
Fig. A. Fig. B.
Check DRAIN FLANGE in SINK to ensure that WHITE FOAM GASKET (3) is fully compressed
and not visible. Fig. A.
DR AIN BODY
4
REAR OF SINK
1
DOWN
M 9 6 8 7 8 6 R e v .1 . 3 M 9 6 8 7 8 6 R e v .1 . 3 M 9 6 8 7 8 6 R e v .1 . 3
Page 3
COMPRESSION NUT
3/8” COMPRESSION CONNECTION
COUPLING NUT
FLEXIBLE SUPPLIES
3/8 O.D.
BULL-NOSE
RISERS
Operate LIFT KNOB (1) to verify that STOPPER (2) opens and closes.
Note: If STOPPER (2) does not open and close properly then refer to the “troubleshooting section” of these instructions.
CHECK OPERATION OF POP-UP
8
1/2" PIPE
THREAD
2
Connect water supply to FAUCET (1) with 1/2" IPS FLEXIBLE SUPPLIES (2) or 3/8" O.D. BULL-NOSE RISERS (3).
Use adjustable wrench to tighten connections. Do not over tighten. Be careful not to kink copper supply when bending. Use tubing cutter to cut to proper length.
Connect 1-1/4” O.D. tailpiece on POP-UP DRAIN to waste outlet.
MAKE WATER SUPPLY AND WASTE CONNECTIONS
9
FERRULE
1
2
3
NOTE: FLEXIBLE SUPPLIES OR BULL-NOSE RISERS MUST BE PURCHASED SEPARATELY.
HOT
COLD
Thread CABLE CONNECTOR (1) clockwise onto DRAIN BODY CONNECTION (2) and
hand tighten. Fig. A.
Your new POP-UP DRAIN installation is
now complete. Fig. B.
Note: Tailpeice on pop-up drain is 1-1/4” O.D. Fig. B.
Fig. A.
ATTACH CABLE CONNECTOR
7
2
1
Fig. B.
1-1/4” O.D.
1
3
Page 4
2
1
4
1
SERVICE
10
TEST INSTALLED FITTING
With HANDLES (1) in OFF position, turn on WATER SUPPLIES (2) and check all connections for leaks.
Remove AERATOR (3).
Operate both HANDLES (1) to flush water lines thoroughly.
Replace AERATOR (3).
5
2
CHECK DRAIN CONNECTIONS
Operate POP-UP KNOB (4) and fill lavatory with water. Check that DRAIN STOPPER (5) makes a good seal and retains water in SINK. If DRAIN STOPPER (5) does not seal properly, please refer to Troubleshooting section in these instructions.
Release POP-UP KNOB (4) down and check all drain connections and "P" trap for leaks. Tighten if necessary.
12
11
“P” TRAP
WASTE OUTLET
3
If spout drips, operate handles several times from OFF to ON position. Do not force - handles turn only 90˚.
To change direction of handle rotation, proceed as follows:
Turn valve to OFF position.
Remove IINDEX (1) and HANDLE SCREW (2).
Pull HANDLE (3) and ESCUTCHEON (4) off.
Remove ADAPTER (5) and SPRING CLIP (6).
Lift STOP WASHER (7), turn 90˚ and replace.
Replace SPRING CLIP (6).
Replace ADAPTER (5), ESCUTCHEON (4) HANDLE (3), SCREW (2), and INDEX (1).
2
1
3
4
90˚
6
7
8
5
4
Remove AERATOR (8) and rinse clean if water flow becomes distorted.
DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER.DRY WITH A SOFT COTTON FLANNEL CLOTH.
DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A CLOTH WITH A COARSE SURFACE.
CARE INSTRUCTIONS:
Page 5
Speed Connect™ Drain
Troubleshooting Guide
Disconnect the Cable from the Drain by threading the Cable Connector (1) counter-clockwise. Fig. A.
Look at the area on the Drain Body where the Cable was attached and locate the component labeled as “Cam” and “Cam Cap” in the illustration. Fig. B.
Use fingers or small screwdriver under either side of the Cam Cap to pry it out from the Drain. Fig. D.
Remove the Cam by pulling it straight out while wiggling gently to loosen the Rubber Seal. Fig. E.
The Stopper can now be removed by lifting it out of the Drain. Fig. F.
CAM
CAM CAP
CABLE ADJUSTMENT PROCEDURE
If sink does not hold water even though Stopper is in the “down” position:
• Follow CABLE ADJUSTMENT PROCEDURE.
If Stopper does not raise up fully or sink drains too slowly:
• Follow CABLE ADJUSTMENT PROCEDURE.
If you need to remove the Stopper:
• Follow STOPPER REMOVAL PROCEDURE.
If you would like the ability to remove your Stopper simply by lifting it out of the drain:
Follow STOPPER INSTALLATION PROCEDURE for “Unlocked” mode.
Fig. B.Fig. A.
REMOVE CAM
Fig. E.
Fig. F.
Disconnect the Cable from the Drain by threading the Cable Connector (1) counter-clockwise. Fig. A.
Look at the area on the Drain Body where the Cable was attached and locate the component labeled as “Cam” in the illustration. Fig. B.
Use a small screwdriver to rotate the Cam in the clockwise direction as far as it will go. At this point the Stopper should be in the UP position. Fig. B, C.
Push DOWN on the Lift-Knob to make sure it is fully down. Fig. C.
Re-attach the Cable to the Drain Body Connection (2) by threading the Cable Connector (1) clockwise onto the Drain Body Connection (2) and hand-tighten. Fig. A.
STOPPER REMOVAL PROCEDURE
LOOP TOWARD FRONT OF SINK
180˚
DRAIN
Fig. H.
LOGO
DRAIN
Fig. G.
2
1
RE-ATTACH
DISCONNECT
Fig. D.
REMOVE CAM CAP
Fig. C.
STOPPER
1
DOWN
5 6
1
2
DR AI N OUTL ET
1
3
4
Page 6
STOPPER INSTALLATION PROCEDURE
Locked Mode:
Look at the Plastic Loop at the bottom of the Stopper and notice that the Loop is on one side of the Stopper. Fig. G.
To install the stopper in “Locked” mode, insert the Stopper into the Drain so that the Plastic Loop is facing toward the rear of the Sink and the American Standard logo is facing front. Rotate Stopper slightly if necessary so that the Stopper slides all the way down.Fig. G.
Re-install the Cam into the Drain, rotating the Cam if necessary to make sure it is fully inserted. Fig. J.
Re-install the Cam Cap, making sure the guide teeth are facing outward. If the Cam Cap does not “snap” into place, then rotate the Cam to make sure it is fully inserted. Fig. K.
Re-attach Cable. See “CABLE ADJUSTMENT PROCEDURE” in Troubling Shooting Guide to complete installation. Stopper will be in “Locked” mode and not be removable.
Unlocked Mode:
Look at the Plastic Loop at the bottom of the Stopper and notice that the Loop is on one side of the Stopper. Fig. H.
To install the stopper in “Unlocked” mode, insert the Stopper into the Drain so that the Plastic Loop is facing toward the front of the Sink and the American Standard logo is facing rear. Rotate Stopper slightly if necessary so that the Stopper slides all the way down. Fig. H.
Re-install the Cam into the Drain, rotating the Cam if necessary to make sure it is fully inserted. Fig. J.
Re-install the Cam Cap, making sure the guide teeth are facing outward. If the Cam Cap does not “snap” into place, then rotate the Cam to make sure it is fully inserted. Fig. K.
Re-attach Cable. See “CABLE ADJUSTMENT PROCEDURE” in “Troublingshooting Guide” to complete installation. Stopper will be in “Unlocked” mode and removable
.
Fig. J. Fig. K.
INSTALL CAM CAP
CAM
INSTALL CAM
The Stopper can be installed two ways, “Locked” Mode (Stopper cannot be removed) or “Unlock” Mode (Stopper is removable).
Unlocked Mode
LOOP TOWARD FRONT OF SINK
180˚
DRAIN
Fig. H.
Locked Mode
(Vandal Proof)
LOGO
DRAIN
Fig. G.
LOOP TOWARD REAR OF SINK
1
2
DR AI N OUTL ET
1
3
4
LOGO
Loading...