INSTALLATION INSTRUCTIONS
AFWALL 1.6 GPF FLUSH VALVE
WALL-MOUNTED TOILETS
Model 2254, 2256, 2257, 2258
Meets the American Disabilities Act Guidelines and ANSI A117.1
Requirements for the Physically Challenged
Thank you for selecting American Standard - the benchmark of fine quality for over 100 years. To ensure this
product is installed properly, please read these instructions carefully before you begin. (Certain installations may
require professional help.) Also be sure your installation conforms to local codes.
CAUTION: PRODUCT IS FRAGILE. TWO PEOPLE ARE RECOMMENDED FOR
!
HANDLING TO AVOID BREAKAGE AND POSSIBLE INJURY!
NOTE:
RECOMMENDED TOOLS AND MATERIALS
Closet Carrier Support
Putty Knife
1
19mm
(3/4)
98mm
(3-7/8)
70mm
(2-3/4)
133mm
(5-1/4)
Refer to instructions supplied with wall carrier for proper installation of 4-bolt support
system wall cavity requirements and rough-in information for waste outlet piping.
For proper operation product requires a minimum of 30 psi working line pressure
Regular Screwdriver
Adjustable Wrench
Pictures may not exactly define contour of china
1" N.P.T. OR C.W.T. SUPPLY
AS REQUIRED TO FLUSH VALVE
C/L
121mm
(4-3/4)
375mm
(14-3/4)
229mm
(9)
C/L OF
OUTLET
1" C.W.T. OR N.P.T. SUPPLY
AS REQ'D NOT FURNISHED
41mm
(1-5/8)
89mm
(3-1/2)
(4) 22mm (7/8)
DIA. HOLES
381mm
(15)
or
432mm
(17)
381mm
(15)
or
432mm
(17)
1-1/2 SPUD
(4) 22mm
(7/8)
HOLES
121mm
(4-3/4)
292mm
(11-1/2)
191mm
(7-1/2)
133mm
or
(5-1/4)
254mm
(10)
38mm
(1-1/2)
VACUUM BREAKER
375mm
(14-3/4)
C/L OF
OUTLET
C/L
229mm
19mm
98mm
(3-7/8)
70mm
(2-3/4)
(3/4)
FINISHED WALL
635mm
(25)
73mm
(2-7/8)
32mm
(1-1/4)
FOR WALLS UP TO 1" IN THICKNESS FOR EACH INCH
ADDITIONAL THICKNESS OF WALL ADD 25mm (1) TO
MEASUREMENT SHOWN
(5-1/4)
133mm
470mm
(18-1/2)
C/L OF SEAT POST
HOLES 140 mm
(5-1/2) CENTER
330mm
(13)
FINISHED
FLOOR
FINISHED WALL
95mm
(3-3/4)
635mm
(25)
38mm (1-1/2) DIA. HOLE IN WALL
76mm(3) DIA. HOLE IN WALL
FOR 1-1/2 SPUD
470mm
(18-1/2)
C/L OF SEAT POST HOLES
140mm(5-1/2) CENTERS
330mm
(13)
FINISHED
FLOOR
32mm
(1-1/4)
Sealant
Tape Measure
When installed,
top of seat is
17" to 19"
(432mm to 483mm)
from the finished
floor.
184mm
(7-1/4)
298mm
(11-3/4)
133mm
(5-1/4)
191mm
(7-1/2)
or
184mm
(7-1/4)
(9)
2
Carpenters Level
Flush Valve
FIXTURE MOUNTING
Fixture studs should project
1-7/8" (48mm) from face of
finished wall.
FINISHED
WALL
1-7/8"
(48mm)
(4) STUDS
Side View
Front View
SAVE FOR FUTURE USE
Product names listed herein are trademarks of American Standard Inc.
© American Standard Inc. 2000
Saniwares
730484-100
3
Place back-up nuts on both bottom bolts, and
the top left-hand bolt only.
4
Using a level, adjust the top left back-up nut so that
it is in the same vertical plane as the lower left back-up
nut. (If wall surface is irregular, the three back-up
Adjust the two lower back-up nuts so that front
face of nuts is flush with finished wall.
nuts must be positioned to allow a minimum 1/16"
gap between fixture and wall surface.)
Adjust waste horn to project 5/16" (7mm) from
finished wall.
FINISHED WALL
CLOSET
CARRIER
SYSTEM
(3) NUTS
5/16 (7mm)
5
NOTE: Bearing nuts and washers must be set
to take full loading from the fixture allowing
1/16" (2mm) clearance between fixture and wall.
Follow support manufacturer's recommended
setting of closet outlet connection.
Place felt or neoprene gasket (wax ring not
recommended) on closet outlet.
When the fixture is installed, closet outlet
gasket must be compressed sufficiently to
assure a gas and watertight seal.
WASTE
HORN
FINISHED WALL
1/16" (2mm)
(IRREGULAR
WALL SURFACE)
LEVEL
AMERICAN-STANDARD ONE-YEAR LIMITED WARRANTY
If inspection of this American-Standard plumbing product, within one year after its
initial installation, confirms that it is defective in materials or workmanship, AmericanStandard will repair or, at its option, exchange the product for a similar model.
This warranty does not apply to local building code compliance. Since local
building codes vary considerably, the purchaser of this product should check with a
local building or plumbing contractor to insure local code compliance before
installation.
This warranty shall be void if the product has been moved from its initial place of
installation; if it has been subjected to faulty maintenance, abuse, misuse, accident or
other damage; if it was not installed in accordance with American-Standard's
instructions; or if it has been modified in a manner inconsistent with the product as
shipped by American-Standard.
American-Standard's option to repair or exchange the product under this warranty
does not cover any labor or other costs of removal or installation, nor shall American-
Standard be responsible for any other incidental or consequential damages
attributable to a product defect or to the repair or exchange of a defective
product, all of which are expressly excluded from this warranty. (Some states or
provinces do not allow the exclusion or limitation of implied warranties, so this
exclusion may not apply to you.)
The following steps require a helper:
Install bowl on support using cap nuts and fiber
washers with the back-up nuts and washers.
DO NOT APPLY TOP RIGHT FIBER WASHER
AND CAP NUT UNTIL OTHER CAP NUTS
HAVE BEEN FIRMLY TIGHTENED USING A
WRENCH.
Install top right cap nut with fiber washer and
run up hand tight. Wrench tighten approximately
1/4 turn.
Apply sealant to gap between bowl and finished
wall. Remove excess sealant.
730484-100
This warranty gives you specific legal rights. You may have other statutory rights
that vary from state to state or from province to province, in which case this warranty
does not affect such statutory rights.
For service under this warranty, it is suggested that a claim be made through the
contractor or dealer from or through whom the product was purchased, or that a
service request (including a description of the product model and of the defect) be
sent to the following address:
In the United States:
American Standard Inc.,
P.O. Box 6820
Piscataway, New Jersey 08855
Attention: Director of Consumer Affairs
For residents of the United States,
warranty information may also be
obtained by calling the following
toll free number: (800) 223-0068
Customer Service Manager
Ideal Standard, S.A. de C.V.
Via Morelos #330
Col. Santa Clara
Ecatepec 55540 Edo. Mexico
In Mexico:
In Canada:
American-Standard,
2480 Stanfield Road
Mississauga, Ontario
Canada L4Y 1S2
Toll Free: (800) 387-0369
Toronto Area: (905) 949-4800
- 2 -