American Standard 2257.101 User Manual

Afwall® Millennium™ FloWise®
Elongated Flushometer Toilet
BARRIER FREE
VITREOUS CHINA LESS EVERCLEAN
®
Afwall® Millenium™ FloWise® Elongated Flushometer Toilet LESS EverClean
®
• Wall-mounted ushometer valve toilet
• Vitreous china
• Conventional glaze
• High Efficiency, Low Consumption. Operates in the range of 1.1 gpf to 1.6 gpf (4.2 Lpf to 6.0 Lpf)
• Meets denition of HET (High Efficiency Toilet) when used with a high efficiency ush valve (1.1 gpf -
1.6 gpf or 1.28/1.1 gpf dual ush)
• Maximum Performance (MaP) score of 1,000 grams at 1.1 gpf - 1.6 gpf
• Condensation channel
• Concealed trapway design
• Elongated bowl
• Powerful direct-fed siphon jet action
• 1-1/2" inlet spud
• Fully-glazed 2-1/8" trapway
• 10" x 12" water surface area
• Tested to support static weight load of 1,000 lbs. (454 kg)
2 2 57.10 1 Elongated bowl only, top spud ❏ 26 3 3.101 Elongated bowl only, top spud with
slotted rim for bedpan holding
26 3 4.101 Elongated bowl only, back spud
System MaP* Score:
1,000 grams of miso @ 1.1 gpf to 1.6 gpf when
used with an American Standard ush valve
* Maximum Performance (MaP) testing performed by IAPMO
R&T Lab. MaP Report conducted by Veritec Consulting, Inc. and Koeller and Company.
Component Parts:
047007-0070A Inlet Spud (furnished with bowl)
Nominal Dimensions:
660 x 356 x 381mm (26" x 14" x 15")
Recommended working pressure–between 25 psi at valve when ushing and 80 psi static
Fixture only, less seat, bolt caps, and ushometer valve
Compliance Certications ­Meets or Exceeds the Following Specications:
• ASME A112.19.2/CSA B45.1 for Vitreous
China Fixtures
1.6 gpf: ❏ Sensor-Operated: American Standard Selectronic® DC Power #6065.161.002 (Top Spud) AC Power #6067.161.002 (Top Spud) ❏ Manual: American Standard #6047.161.002 (Top Spud) 1.28 gpf: ❏ Sensor-Operated: American Standard Selectronic DC Power #6065.121.002 (Top Spud) AC Power #6067.121.002 (Top Spud) ❏ Manual: American Standard #6047.121.002 (Top Spud) 1.6 / 1.1 gpf Dual Flush: ❏ Sensor-Operated: American Standard Selectronic® DC Power #6065.761.002 (Top Spud) AC Power #6067.761.002 (Top Spud) 1.28 / 1.1 gpf Dual Flush: ❏ Sensor-Operated: American Standard Selectronic DC Power #6065.721.002 (Top Spud) AC Power #6067.721.002 (Top Spud)
SEE REVERSE FOR ROUGHING-IN DIMENSIONS
To Be Specied:
Color: White Seat: American Standard #5901.100 Heavy duty
open front less cover American Standard #5905.100 Extra heavy duty open front less cover Flushometer Valve:
®
®
MEETS THE AMERICANS WITH DISABILITIES ACT GUIDELINES AND ANSI A117.1 REQUIREMENTS FOR ACCESSIBLE AND USABLE BUILDING FACILITIES - CHECK LOCAL CODES.
When installed so top of seat is 432 to 483mm (17" to 19") from the finished floor.
M127
ENVIROMENTAL
PRODUCT
DE CLAR AT IO N
spec_2257.101 AfwallMillenniumFW Rev 11/18
When used with
1.1 or 1.28 gpf
toilet flush valves
ADA
COMPLIANT
© 2018 AS America Inc.
WATER
EFFICIENT
2257.101/2 6 33 .101
FINISHED WALL
BARRIER FREE
Afwall® Millennium™ FloWise®
Elongated Flushometer Toilet
VITREOUS CHINA LESS EVERCLEAN
®
73mm
(2-7/8")
41mm (1-5/8")
2634 .101
FINISHED WALL
660mm
(26")
660mm
(26")
470mm
(18-1/2")
470mm
(18-1/2")
333mm
(13-1/8")
FINISHED
FLOOR
333mm
(13-1/8")
381mm
(15")
381mm
(15")
356mm
(14")
229mm
(9")
356mm
(14")
(4) Ø 22mm
(7/8") HOLES
229mm
(9")
(4) Ø 22mm
(7/8") HOLES
191mm
(7-1/2")
133mm (5-1/4")
90mm (3-9/16")
321mm
(12-5/8")
281mm
(11-1/16")
191mm (7-1/2")
133mm (5-1/4")
41mm (1-5/8")
NOTES:
Toilet designed to meet ADA accessibility standards when top of seat height set at 432 to 483mm (17" to 19") from nished oor.
PRODUCT 2257 SHOWN, 2366 SAME EXCEPT WITH SLOTTED RIM FOR BED PAN HOLDING.
WASTE OUTLET SEAL RING MUST BE NEOPRENE OR GRAPHITE-FELT (WAX RING NOT RECOMMENDED).
SUGGESTED 2mm (1/16) CLEARANCE BETWEEN FACE OF WALL AND BACK OF BOWL. TO COMPLY WITH AREA CODE GOVERNING THE HEIGHT OF VACUUM BREAKER ON THE FLUSHOMETER VALVE, THE PLUMBER MUST VERIFY DIMENSIONS SHOWN FOR SUPPLY ROUGHING. FLUSHOMETER VALVE NOT INCLUDED WITH FIXTURE AND MUST BE ORDERED SEPARATELY. CARRIER FITTING AS REQUIRED TO BE FURNISHED BY OTHERS. PROVIDE SUITABLE REINFORCEMENT FOR ALL WALL SUPPORT.
IMPORTANT: Dimensions of xtures are nominal and may vary within the range of tolerances established by ANSI Standard A112.19.2. These measurements are subject to change or cancellation. No responsibility is assumed for use of superseded or voided pages
FINISHED
FLOOR
M128
spec_2257.101 AfwallMillenniumFW Rev 11/18
© 2018 AS America Inc.
Loading...