American Standard 2175.502 User Manual

Page 1
Installation
Instructions
COLONY SOFT
Single Control Lavatory Faucet
with SpeedConnect™ Drain
Congratulations on purchasing your American Standard faucet with SpeedConnect drain, a feature found only on American Standard faucets.
2175.502
Certified to comply with ANSI A112.18.1
SpeedConnect Drain*
M968881
• Fewer parts, installs in less time
• Never needs adjustment
• Guaranteed to seal properly the first time, every time.
*Your new American Standard faucet is designed to work only with the SpeedConnect drain.
To ensure that your installation proceeds smoothly-please read these instructions carefully before you begin.
Required tools
Adjustable Wrench Screwdriver Channel Locks
INSTALL FAUCET
1
Apply a bead of putty along the edge of the underside of the FAUCET (1).
Insert FAUCET (1) and CABLE CONNECTOR (2) through center hole of mounting surface. Fig. A.
From under side of mounting surface thread the two MOUNTING NUTS (2) onto FAUCET SHANKS (4). Fig. B.
CAUTION
Turn off hot and cold water supplies before beginning.
Plumbers' Putty or Caulking
Fig. A.
1
Tubing Cutter
Center FAUCET (1) and hand tighten MOUNTING NUTS (3) to secure FAUCET (1).
3
(HAND TIGHTEN)
Fig. B.
4
PUTTY
3
2
1
Page 2
POP-UP DRAIN
2
Fig. A. Fig. B.
Remove CLEAR PLASTIC COVER (1).
Remove CARDBOARD SPACER (2) from under DRAIN POP-UP (3).
Tighten TAILPIECE (4) on DRAIN BODY before installing DRAIN BODY.
REMOVE FLANGE
3
Thread FLANGE (1) counter-clockwise and remove FLANGE (1) and FOAM GASKET (2) from drain body.
Fig. A.
Thread LOCKNUT (3) clock-wise to bottom of drain body. Push GASKET (4) down against LOCKNUT (3).
Fig. B.
Fig. B.
1
3
2
Fig. A. Fig. B.
1
2
4
3
DRAIN BODY
4
INSTALL DRAIN FROM
4
BELOW FIXTURE
From under side of SINK install DRAIN BODY (1) up through drain outlet.
Note: No plumber’s putty or caulk is required. The CABLE ATTACHMENT POINT (2) must face towards the rear of the SINK.
Install FOAM GASKET (3) and FLANGE (4) onto drain body from above SINK and tighten FLANGE (4) firmly.
FLANGE GASKET AND POP-UP KNOB
6
Check DRAIN FLANGE in SINK to ensure that WHITE FOAM GASKET (3) is fully compressed and not visible. Fig. A.
POP-UP KNOB (1) must be fully down. Fig. B.
4
3
TIGHTEN LOCKNUT
5
Tighten LOCKNUT (1) firmly with Adjustable Wrench or Channel Locks.
DRAIN OUTLET
REAR OF SINK
1
2
Fig. A. Fig. B.
WHITE FOAM GASKET NOT VISIBLE
DRAIN FLANGE
1
DOWN
1
M968881
2
Page 3
ATTACH CABLE CONNECTOR
7
Thread CABLE CONNECTOR (1) clockwise onto DRAIN BODY CONNECTION (2) and hand tighten. Fig. A.
Your new POP-UP DRAIN installation is now complete. Fig. B.
Note: Tailpeice on pop-up drain is 1-1/4” O.D. Fig. B.
Fig. A.
Fig. B.
1
CHECK OPERATION OF POP-UP
8
Operate LIFT KNOB (1) to verify that STOPPER (2) opens and closes.
Note: If STOPPER (2) does not open and close properly then refer to the “troubleshooting section” of these instructions.
MAKE WATER SUPPLY AND WASTE CONNECTIONS
9
NOTE: FLEXIBLE SUPPLIES OR BULL-NOSE RISERS MUST BE PURCHASED SEPARATELY.
Connect water supply to FAUCET (1) with 1/2" IPS FLEXIBLE SUPPLIES (2) or 3/8" O.D. BULL-NOSE RISERS (3).
2
1-1/4” O.D.
1
2
Use adjustable wrench to tighten connections. Do not over tighten. Be careful not to kink copper supply when bending. Use tubing cutter to cut to proper length.
Connect 1-1/4” O.D. tailpiece on POP-UP DRAIN to waste outlet.
3/8” COMPRESSION
CONNECTION
3
1/2" PIPE
THREAD
2
FLEXIBLE
SUPPLIES
HOT
1
COUPLING NUT
3/8 O.D.
BULL-NOSE
RISERS
COMPRESSION NUT
FERRULE
COLD
3
M968881
Page 4
10
TEST INSTALLED FITTING
With HANDLE (1) in OFF position, turn on WATER SUPPLIES (2) and check all connections for leaks.
Ensure that AERATOR (3) is tightened completely.
Operate HANDLE (1) to allow water flow.
CHECK DRAIN CONNECTIONS
Operate POP-UP KNOB (4) and fill lavatory with water. Check that DRAIN STOPPER (5) makes a good seal and retains water in SINK. If DRAIN STOPPER (5) does not seal properly, please refer to Troubleshooting section in these instructions.
Release POP-UP KNOB (4) down and check all drain connections and "P" trap for leaks. Tighten if necessary.
WASTE OUTLET
4
1
3
5
11
SERVICE
If Faucet Drips Proceed As Follows:
Turn VALVE in OFF position. If faucet drips, operate handle several times from "off" to "on".
Do not apply excessive force.
Clogged CARTRIDGE INLETS may cause reduced flow in "full on" hot or cold. To clean inlets, first turn off water supply, then:
Remove HANDLE (1), CAP (2) and CARTRIDGE (3).
Clean CARTRIDGE INLETS and MANIFOLD.
Reassemble CARTRIDGE (3), alternately tightening SCREWS (4). Replace CAP (2) and HANDLE (1). Check flow.
2
CARTRIDGE INLETS
2
“P” TRAP
1
2
4
3
MANIFOLD
12
DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.
DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A CLOTH WITH A COARSE SURFACE.
CARE INSTRUCTIONS:
M968881
4
Page 5
SpeedConnect™ Drain
Troubleshooting Guide
If sink does not hold water even though Stopper is in the “down” position:
• Follow CABLE ADJUSTMENT PROCEDURE.
If Stopper does not raise up fully or sink drains too slowly:
• Follow CABLE ADJUSTMENT PROCEDURE.
If you need to remove the Stopper:
• Follow STOPPER REMOVAL PROCEDURE.
If you would like the ability to remove your Stopper simply by lifting it out of the drain:
Follow STOPPER INSTALLATION PROCEDURE for “Unlocked” mode.
CABLE ADJUSTMENT PROCEDURE
Disconnect the Cable from the Drain by threading the Cable Connector (1) counter-clockwise. Fig. A.
Look at the area on the Drain Body where the Cable was attached and locate the component labeled as “Cam” in the illustration. Fig. B.
Use a small screwdriver to rotate the Cam in the clockwise direction as far as it will go. At this point the Stopper should be in the UP position. Fig. B, C.
Push DOWN on the Lift-Knob to make sure it is fully down. Fig. C.
Re-attach the Cable to the Drain Body Connection (2) by threading the Cable Connector (1) clockwise onto the Drain Body Connection (2) and hand-tighten. Fig. A.
DOWN
1
RE-ATTACH
DISCONNECT
Fig. B. Fig. C.Fig. A.
CAM
CAM CAP
2
STOPPER REMOVAL PROCEDURE
Disconnect the Cable from the Drain by threading the Cable Connector (1) counter-clockwise. Fig. A.
Look at the area on the Drain Body where the Cable was attached and locate the component labeled as “Cam” and “Cam Cap” in the illustration. Fig. B.
Use fingers or small screwdriver under either side of the Cam Cap to pry it out from the Drain. Fig. D. Remove the Cam by pulling it straight out while wiggling gently to loosen the Rubber Seal. Fig. E. The Stopper can now be removed by lifting it out of the Drain. Fig. F.
Fig. D.
Fig. E.
REMOVE CAM
1
Fig. F.
REMOVE CAM CAP
M968881
5
Page 6
STOPPER INSTALLATION PROCEDURE
The Stopper can be installed two ways, “Locked” Mode (Stopper cannot be removed) or “Unlock” Mode (Stopper is removable).
Locked Mode:
Look at the Plastic Loop at the bottom of the Stopper and notice that the Loop is on one side of the Stopper. Fig. G.
To install the stopper in “Locked” mode, insert the Stopper into the Drain so that the Plastic Loop is facing toward the rear of the Sink and the American Standard logo is facing front. Rotate Stopper slightly if necessary so that the Stopper slides all the way down.Fig. G.
Re-install the Cam into the Drain, rotating the Cam if necessary to make sure it is fully inserted. Fig. J.
Re-install the Cam Cap, making sure the guide teeth are facing outward. If the Cam Cap does not “snap” into place, then rotate the Cam to make sure it is fully inserted. Fig. K.
LOGO
LOOP TOWARD REAR OF SINK
DRAIN
Fig. G.
Re-attach Cable. See “CABLE ADJUSTMENT PROCEDURE” in Troubling Shooting Guide to complete installation. Stopper will be in “Locked” mode and not be removable.
Unlocked Mode:
Look at the Plastic Loop at the bottom of the Stopper and notice that the Loop is on one side of the Stopper. Fig. H.
To install the stopper in “Unlocked” mode, insert the Stopper into the Drain so that the Plastic Loop is facing toward the front of the Sink and the American Standard logo is facing rear. Rotate Stopper slightly if necessary so that the Stopper slides all the way down.
Fig. H.
Re-install the Cam into the Drain, rotating the Cam if necessary to make sure it is fully inserted. Fig. J.
Re-install the Cam Cap, making sure the guide teeth are facing outward. If the Cam Cap does not “snap” into place, then rotate the Cam to make sure it is fully inserted. Fig. K.
Re-attach Cable. See “CABLE ADJUSTMENT PROCEDURE” in “Troublingshooting Guide” to complete installation. Stopper will be in “Unlocked” mode and removable
.
Locked Mode
(Vandal Proof)
Fig. H.
LOGO
180˚
LOOP TOWARD FRONT OF SINK
DRAIN
Unlocked Mode
Fig. J. Fig. K.
INSTALL CAM
CAM
INSTALL CAM CAP
M968881
6