American Standard 2093 Elongated User Manual

S A V E F O R F U T U R E U S E
1
730480-100 Rev B 730480-100 Rev B 730480-100 Rev B 730480-100 Rev B
Saniwares
P ro d u ct na m e s l i s t e d h e r e i n a r e t r a d e m a r k s o f A m e r i c a n S t a n d a r d I n c . © A m e ri c an S ta n d a r d I n c . 2 0 0 6
2
Refer to instructions supplied with wall carrier for proper installation of 4-bolt support system wall cavity requirements and rough-in information for waste outlet piping.
Closet Carrier Support Putty Knife Regular Screwdriver Adjustable Wrench Sealant Tape Measure Flexible Supply Tube Carpenters Level
RECOMMENDED TOOLS AND MATERIALS
Model 2093 Elongated
GLENWALL 1.6 GPF TWO-PIECE PRESSURE-ASSISTED
WALL-MOUNTED TOILETS
INSTALLATION INSTRUCTIONS
Thank you for selecting American Standard - the benchmark of fine quality for over 100 years. To ensure this product is installed properly, please read these instructions carefully before you begin. (Certain installations may require professional help.) Also be sure your installation conforms to local codes.
CAUTION: PRODUCT IS FRAGILE. TWO PEOPLE ARE RECOMMENDED FOR HANDLING TO AVOID BREAKAGE AND POSSIBLE INJURY!
NOTE: For proper operation product requires a minimum of 25 psi working line pressure
30
(762mm)
OR
32
(813mm)
14- 3/4
(37 5mm )
9
(22 9mm )
29-1/2
(749mm)
7-1/2
(191mm)
191 mm
(7- 1/2 )
14- 1/2
(36 8mm )
OR
16- 1/2
(41 9mm )
C/L OF WASTE OUT LET
(4) 7/ 8 (22 mm) DIA. H OLE S
SUP PLY AS REQ UIR ED
*
5/8
(16 mm)
3-1 /4
(83 mm)
1-1 /2
(38 mm)
5-1/4
(133mm)
3-7/8
(98mm)
FIN ISH ED WALL
FIN.
FLOOR
3-1/4 (83mm)
3/4 (19mm) REF.
6
(152mm)
8-1 /2
(21 6mm )
4-1/8
(105mm)
OR
6-1/8
(156mm)
19- 1/2
(49 5mm)
C/L
FIXTURE MOUNTING
Fixture studs should project 2-1/8" from face of finished wall.
Front ViewSide View
FINISHED WALL
2-1/8"
(4) STUDS
Meets the American Disabilities Act Guidelines and ANSI A117.1 Requirements for the Physically Challenged
When installed, top of seat is 17" to 19" (432mm to 483mm) from the finished floor.
!
Place back-up nuts on both bottom bolts, and the top left-hand bolt only.
Adjust the two lower back-up nuts so that front face of nuts is flush with finished wall.
Adjust waste horn to project 5/16" from finished wall.
Using a level, adjust the top left back-up nut so that it is in the same vertical plane as the lower left back-up nut. (If wall surface is irregular, the three back-up nuts must be positioned to allow a minimum 1/16" gap between fixture and wall surface.)
NOTE: Bearing nuts and washers must be set to take full loading from the fixture allowing 1/16" clearance between fixture and wall.
Follow support manufacturer's recommended setting of closet outlet connection.
Place felt or neoprene gasket (wax ring not recommended) on closet outlet.
When the fixture is installed, closet outlet gasket must be compressed sufficiently to assure a gas and watertight seal.
Install bowl on support using cap nuts and fiber washers with the back-up nuts and washers.
DO NOT APPLY TOP RIGHT FIBER WASHER AND CAP NUT UNTIL OTHER CAP NUTS HAVE BEEN FIRMLY TIGHTENED USING A WRENCH.
Install top right cap nut with fiber washer and run up hand tight. Wrench tighten approximately 1/4 turn.
Apply sealant to gap between bowl and finished wall. Remove excess sealant.
SPONGE WASHER
TANK MTG.
BOLTS
SANITARY
BAR
NUT
WASHER
3
5
6
4
!
- 2 -
FINISHED WALL
CLOSET CARRIER SYSTEM
(3) NUTS
WASTE HORN
5/16
LEVEL
FINISHED WALL
1/16" (IRREGULAR WALL SURFACE)
Install large rubber gasket over threaded outlet on bottom of tank with tapered side out and lower tank onto bowl so that the tapered end of gasket fits evenly into bowl water inlet opening, and tank mounting bolts go through mounting holes. Secure with metal washers and nuts.
With tank parallel to wall, alternately tighten nuts until tank is snugged down evenly against sanitary bar on bowl.
Install toilet seat according to manufacturer's directions.
CAUTION: DO NOT OVERTIGHTEN
NUTS MORE THAN REQUIRED
FOR A SNUG FIT!
INSTALL TANK AND TOILET SEAT
The following steps require a helper: