Place back-up nuts on both bottom bolts, and
the top left-hand bolt only.
Adjust the two lower back-up nuts so that front
face of nuts is flush with finished wall.
Adjust waste horn to project 5/16" from
finished wall.
Using a level, adjust the top left back-up nut so that
it is in the same vertical plane as the lower left back-up
nut. (If wall surface is irregular, the three back-up
nuts must be positioned to allow a minimum 1/16"
gap between fixture and wall surface.)
NOTE: Bearing nuts and washers must be set
to take full loading from the fixture allowing
1/16" clearance between fixture and wall.
Follow support manufacturer's recommended
setting of closet outlet connection.
Place felt or neoprene gasket (wax ring not
recommended) on closet outlet.
When the fixture is installed, closet outlet
gasket must be compressed sufficiently to
assure a gas and watertight seal.
Install bowl on support using cap nuts and fiber
washers with the back-up nuts and washers.
DO NOT APPLY TOP RIGHT FIBER WASHER
AND CAP NUT UNTIL OTHER CAP NUTS
HAVE BEEN FIRMLY TIGHTENED USING A
WRENCH.
Install top right cap nut with fiber washer and
run up hand tight. Wrench tighten approximately
1/4 turn.
Apply sealant to gap between bowl and finished
wall. Remove excess sealant.
SPONGE
WASHER
TANK MTG.
BOLTS
SANITARY
BAR
NUT
WASHER
3
5
6
4
!
- 2 -
FINISHED WALL
CLOSET
CARRIER
SYSTEM
(3) NUTS
WASTE
HORN
5/16
LEVEL
FINISHED WALL
1/16" (IRREGULAR
WALL SURFACE)
Install large rubber gasket over threaded outlet on
bottom of tank with tapered side out and lower tank onto
bowl so that the tapered end of gasket fits evenly into
bowl water inlet opening, and tank mounting bolts go
through mounting holes. Secure with metal washers
and nuts.
With tank parallel to wall, alternately tighten nuts until
tank is snugged down evenly against sanitary bar on
bowl.
Install toilet seat according to manufacturer's directions.
CAUTION: DO NOT OVERTIGHTEN
NUTS MORE THAN REQUIRED
FOR A SNUG FIT!
INSTALL TANK AND TOILET SEAT
The following steps require a helper: