Thank you for selecting American-Standard... the benchmark of fine quality for over 100 years.
To ensure that your installation proceeds smoothly-­please read these instructions carefully before you begin.
To ensure that your installation proceeds smoothly-please read these instructions carefully before you begin.
Recommended Tools
Flat Blade Screwdriver
Adjustable Wrench
Channel Locks
Tubing Cutter
*Wrench
*Hex key
*Supplied with Fitting
ROUGHING-IN DIMENSIONS
9-1/2"
(240mm)
MOUNTING
SURFACE
6-3/4"
(170mm)
9-3/4"
(247mm)
1-3/16" MAX.
(30mm) MAX.
3/4-14 MALE
N.P.T. INLETS
2-3/4"
(71mm)
1-1/8 D.
3-1/4" D.
(82mm) D.
(H)
1-1/16 D. (27mm) D.
Certified to comply with ANSI A112.18.1M
M968830 Rev.1.4
6-1/2" to 12"
(165mm to 305mm)
2" D.
(52mm) D.
3'
(76mm)
(C)
12 MAX. (305mm)
2-1/16" D.
(52mm) D.
1-1/2 MAX.
(38mm) MAX.
1-3/16 D. (30mm) D.
SPOUT ASSEMBLY
1
CAUTION
Install RUBBER RING (1) into ESCUTCHEON RING (2) and place over mounting hole.
Insert SPOUT SHANK (3) through center hole of MOUNTING LEDGE. Make sure that the RUBBER RING (1) is properly seated in RECESS
of ESCUTCHEON RING (2).
Assemble RUBBER WASHER (4) and BRASS WASHER (5) onto SHANK (3). From underside of ledge secure SPOUT (7) into position with LOCKNUT (6).
7
2
RECESS
3
1
MOUNTING SURFACE
PREPARE TUBE AND TEE ASSEMBLY
2
Prepare TUBE and TEE ASSEMBLY (1) to fit center to center VALVE (2) location (between 6-1/2" and 12"). If necessary, cut and/or bend TUBING carefully. Make sure tube bend is close to the TEE (1) so that it will not effect the compression joint at the VALVE CONNECTION.
Remove COUPLING NUT (3) and FERRULE (4) from each VALVE (2) and slide onto TUBING (5).
4
3
1
5
6-1/2" to 12"
(165mm to 305mm)
MOUNTING
SURFACE
3
4
4
2
5
6
NOTE
VALVE inlet is 3/4-inch NPT male.
VALVE ASSEMBLY
3
Install LOCKNUTS (1) and RUBBER WASHERS (2) onto valve shanks.
Push TUBING (3) ends into VALVE (4) side outlets. Insert VALVES (4) into mounting holes from underside of ledge.
Press TEE (5) onto SPOUT SHANK (6) making certain that the O-RING (7) is properly seated on SHANK (6). Push COUPLING (8) into TEE (5) and attach to SPOUT SHANK (6) and tighten using a 10mm (3/8'') hex wrench. Tighten COUPLING (8) using a 10mm (3/8") Hex wrench. (FOR 2064.901). Use COUPLING (8a) for fitting less spray.
Thread of VALVE BODY (4) should extend at least 5/16 inch above MOUNTING SURFACE (11). If necessary, adjust LOCKNUT (1).
Place RUBBER RING (10) into ESCUTCHEON ADAPTERS (9) and thread onto valves until snug against internal stop.
Tighten LOCKNUT (1) with WRENCH supplied to secure VALVE (4) position.
Slide FERRULE (12) and COUPLING NUT (13) to outlet of VALVE (4) and tighten COUPLING NUT (13) firmly.
Connect HOT water supply to inlet of left VALVE and COLD water supply to inlet of right VALVE using appropriate connector.
9
11
2
1
MOUNTING SURFACE
Wrench
5/16'' MIN.
10
4
9
10
HOT
8a
11
MOUNTING
SURFACE
9
10
4
7
12
13
3
5
8
13
6
12
4
COLD
INSTALL HANDLES
4
Push ADAPTER (1) on VALVE STEM (2). See figure "A". Tighten STEM SCREW (3) to secure ADAPTER (1).
Find correct position of LEVER HANDLE ASSEMBLY (4) by adjusting male teeth on ADAPTER (1) to female teeth in HANDLE (4).
Thread LEVER HANDLE ASSEMBLY (4) onto DECK ADAPTER (5) until snug against mounting surface
SERVICE
5
To change direction of handle rotation, proceed as follows:
Turn valve to OFF position. Thread counter-clock wise HANDLE BASE (1) to remove HANDLE ASSEMBLY (2) from ESCUTCHEON BASE (3). Use a flat blade screw driver to remove SPRING CLIP (4). Lift STOP WASHER (5), turn 90˚ and replace. Replace SPRING CLIP (4). Reinstall HANDLE ASSEMBLY (2).