American Standard 1742 User Manual

COLONY OVAL™
HIGH GLOSS ACRYLIC SHOWN LESS ALL FITTINGS
ON/OFF
SWITCH
292 mm (11-1/2)
SEE FTTG.SPECS
FOR DIMENSION
OF SUPPLIES
C
L
305mm(12) X 229 mm(9)
1041 mm
(41)
535mm
(21)
98mm
(3-7/8)
OF DRAIN
C
L
OUTLET
82mm
(3-1/4)
51mm
(2)
605mm
(23-7/8 )
555mm
(21-7/8)
BATH
SUPPORT
MATERIAL
INSTALLED SIZE WEIGHT WEIGHT w/WATER GAL. TO OVERFLOW WHIRLPOOL MIN. OPERATING VOL. BATHING WELL AT SUMP BATHING WELL AT RIM WATER DEPTH TO OVERFLOW FLOOR LOADING (PROJECTED AREA)
102mm
305mm
(4)
(12)
1-1/2 N.P.T.M.
1-1/2 O.D.
TAILPIECE
GENERAL SPECIFICATIONS FOR 1742 WHIRLPOOL
WHIRLPOOL ELECTRICAL SPECIFICATIONS
CUTOUT IN FLOOR FOR DRAIN
(2) AIR VALVES
C/L OF
VALVES
THREADS
71 x 41 x 23-7/8 In.(1805 x 1040 x 606mm)
1742 SERIES WHIRLPOOL/BATHING POOL
INSTALLATION INSTRUCTIONS
1803 mm
C/L OF SPOUT
35mm
(1-3/8)
(71)
OUTLINE OF CUTOUT-USE TEMPLATE
PUMP MAY EXTEND TO THE RIM
PROVIDE ACCESS
TO PUMP FOR
SERVICING ON ALL
INSTALLATIONS
C/L OF
SHOWER ARM
1651-1981mm
(65-78)
OPTIONAL
ROUGH FLOOR
98mm (3-7/8)
119 Lbs. (54 Kg.)
680 Lbs. (308 Kg.)
67 Gal. (254 L)
49 x 26 In. (1245 x 660mm) 62 x 34 In. (1588 x 864mm)
32 Lbs./Sq.Ft. (157 Kgs./Sq.m)
50 Gal. (190 L)
16-7/8 In. (429mm)
1.1 HP, 9.9 AMPS, 120V.PUMP
THANK YOU...
for selecting an American Standard bath. Your new bath is shipped to you after careful inspection. The whirlpool version is completely assembled with pump, motor, and system piping. All you need to finish the installation are your selected fittings and electrical connections for a whirlpool.
To insure maximum performance and pleasure from this product, please follow the instructions and cautions.
List of Required Components (not included):
• Drain 1583.470*
• Bath Filler*
* see your American Standard Distributor
List of Required Tools and Supplies: Tools
• Level
• Tape Measure
• Pipe Wrench
• Slip Joint Pliers
• Screw Driver
• Standard Woodworking Tools
• Personal Safety Equipment
• Caulking Gun
Supplies
• Nails
• Putty
• Caulking (waterproof)
• 1 x 3 or 2 x 2 Stringers
• Drop Cloth
• 15 amp GFCI Outlet
• Cement, Plaster, Grout
IMPORTANT: Water test unit before installation
GENERAL INSTALLATION INFORMATION
and enclosure!
Carefully uncrate and inspect your new bath for any shipping damage. If such damage is found, report it to your vendor immediately.
After inspection and during installation, protect the bath from construction damage. AFTER INSTALLATION, AND
BEFORE ENCLOSING WITH WALLBOARD, TILE, ETC., WATER TEST THE UNIT AND CHECK FOR LEAKS.
Do not make modifications to the whirlpool system or remove pump from factory mounting. This could adversely affect the safety and performance of the whirlpool and void the warranty. Do not handle or move the whirlpool by the pump, motor, or piping system.
Fittings (bath filler, shower arm, etc.) are not provided with the bath and must be ordered separately. Framing and enclosing materials are provided by others. Check for availability of optional American Standard wall tiling bead (required for recess installations).
Protect all finished surfaces of the whirlpool during construction and installation using a drop cloth.
WARNING! Do not lift whirlpool by the piping harness at any time.
FOR AFTER-SALES SERVICE CALL 1 (800) 442-1902 WEEKDAYS.
753571-100
© American Standard Inc. 2004 All product names listed herein are trademarks of American Standard Inc. unless otherwise noted.
FRAMING AND INSTALLATION
THE VARIETY OF INSTALLATIONS POSSIBLE FOR THIS BATH MAY REQUIRE FRAMING PROCEDURES OTHER THAN THOSE SHOWN.
LOCATE STUDS AS REQUIRED. INSURE ROUGH DIMENSIONS ARE PROPER, PLUMB AND SQUARE. FOR WHIRLPOOLS, PROVISION MUST
BE MADE IN ALL INSTALLATIONS FOR AN ACCESS OPENING FOR SERVICING PUMP AND CONTROLS.
THE FOLLOWING PROCEDURE MUST BE USED FOR ALL INSTALLATIONS: STRINGER OR PIER HEIGHT SHOULD BE AS INDICATED.
THIS BATH MUST BE SUPPORTED ALONG ITS ENTIRE BOTTOM. We recommend the use of mortar as bedding material (sand is not recommended). Apply enough bedding to support the complete bottom of the bath. After the bedding has been poured, and before it sets, position whirlpool or bath within recess until the rim is leveled against the leveling stringers (see "Typical Recess Installation") shown below. The rim of the bath MUST NOT support weight. Allow the bedding material to completely harden before applying weight to the rim or bottom of the bath. Any finish material such as tile or wall board must
be self-supporting if it contacts the deck of the bath.
SUGGESTED INSTALLATION METHOD
LEVELING SURFACE
WATERPROOF SEALANT
BATH
TYPICAL INSTALLATION
AS DESIRED
21-7/8
(556mm)
*39 (991 mm) CUTOUT
AS DESIRED
ACCESS PANEL
IT MAY BE NECESSARY TO NOTCH THE DECK SURFACE TO ACCOMMODATE THE WHIRLPOOL ON/OFF SWITCH AND/OR THE AIR CONTROL DURING INSTALLATION
*69
(1753 mm)
CUTOUT
24
(610mm)
*SEE CUTOUT TEMPLATE PROVIDED
UNLESS AN ACCESS OPENING OF AT LEAST 12" X 24" (305 X 610 mm) IS PROVIDED, WARRANTY SERVICE WILL NOT BE PERFORMED.
12
(305 mm)
753571-100 (2)
Loading...
+ 2 hidden pages