Installation
Instructions
THREE WAY:
SHOWER SYSTEMS
TWO WAY OR THREE WAY
IN-WALL DIVERTER
Thank you for selecting American-Standard...the benchmark
of fine quality for over 100 years.
To ensure that your installation proceeds smoothly--please
read these instructions carefully before you begin.
CAUTION: DO NOT SEAL ANY OUTLETS. DIVERTER
CANNOT BE USED AS A STOP VALVE.
TWO WAY
BODY
1660.300
1660.430
1660.431
TWO WAY:
1660.200
1660.440
1660.441
MAX
Certified to comply with ANSI A112.18.1M
50321B
ROUGHING-IN DIMENSIONS
NOTE: NO CONCEALED PIPING FURNISHED
2-9/16
THREE WAY
BODY
DISK
O-RINGS
ESCUTCHEON
(1660.200/.300)
LOWER
DISK
STEM
DISK
O-RING
CLIP
ESCUTCHEON
NUT
UPPER
DISK
SHAFT
HANDLE
ADAPTER
WASHER
HANDLE
SPRING
DECORATOR
INDEX
BUTTON
SHAFT
O-RING
WASHER
RING
3-1/8
1-5/8
ALL CONNECTIONS 1/2" NPT
CAP
CAP
SEAL
HANDLE
SCREW
CAP
HANDLE
(1660.431/.441)
2-1/4
FINISHED
WALL
PLASTER
GUARD
MAX
HANDLE
(1660.430/.440
Printed in Germany
HANDLE
ADAPTOR
HANDLE
SCREW
HANDLE
SKIRT
HANDLE
SCREW
VANDAL-RESISTANT
INDEX CAP
VANDAL-RESISTANT
HANDLE SCREW
1
ROUGHING-IN
Turn off hot and cold water supplies before beginning.
CAUTION
See Roughing-in Drawing on reverse side. The port with the BATH TUB picture is the high flow.
The DIVERTER can be installed with the inlet rotated in any position.
Supply connections are 1/2" NPT connections.
For proper positioning the finished wall must be within side of PLASTER GUARD.
Connect water to valve. The reverse side of the body is marked with arrows.
CAUTION: Do not solder near the VALVE. Damage to the SEAL may occur.
Do not seal any outlets. The DIVERTER cannot be used as a stop valve.
For support use pipe braces secured to wooden braces.
TEST DIVERTER
2
Check that the DIVERTER operates correctly and does not leak.
DIVERTER
To do this, screw off the PLASTER GUARD, turn around, and
insert using the fluted pin into the fluting on the DIVERTER SPINDLE
and use as a diverter knob. Screw the PLASTER GUARD back on.
Have the wall tiled only with the PLASTER GUARD screwed on.
INSTALL TRIM
(For 1660.200/.300, handles are
3
purchased separately.)
When finished tiling wall, remove
PLASTER GUARD.
Place ESCUTCHEON on ESCUTCHEON
HOLDER and screw HOLDER onto VALVE.
For 1660.430/.440 Series:
Push HANDLE ADAPTER onto STEM.
Make sure arrow is up.
Assemble HANDLE and DECORATOR RING onto
ESCUTCHEON
HANDLE ADAPTER. Secure with HANDLE SCREW.
Snap on HANDLE CAP.
Check for leaks.
To operate, turn the HANDLE clockwise or counter clockwise.
For 1660.431/.441 Series:
HANDLE
SKIRT
Assemble HANDLE SKIRT then HANDLE LEVER to ESCUTCHEON NUT STEM. Secure
with HANDLE SCREW.
Push on INDEX BUTTON or screw on VANDAL RESISTANT INDEX CAP.
Check for leaks.
To operate, turn the HANDLE clockwise or counter clockwise.
ESCUTCHEON
NUT STEM
HANDLE
ADAPTER
HANDLE
SCREW
DIVERTER
SPINDLE
HANDLE
INDEX
BUTTON
PLASTER
GUARD
MAX
DECORATOR
RING
HANDLE
SCREW
VANDAL-RESISTANT
INDEX CAP
VANDAL-RESISTANT
HANDLE SCREW
CAP
SERVICE
4
To Replace O-Rings:
Turn off water supply.
For 1660.430/.440 Series:
Use a small screw driver to
remove HANDLE CAP.
Remove HANDLE SCREW, DECORATOR
RING, HANDLE and ADAPTER.
Unscrew ESCUTCHEON HOLDER and
remove HOLDER and ESCUTCHEON.
Unscrew CAP and remove STEM,
SPRING and SEALS.
Remove old DIVERTER elements and
install new parts.
Replace remaining parts in reverse order.
For 1660.431/.441 Series:
Remove INDEX BUTTON (or unscrew VANDAL RESISTANT INDEX CAP).
Remove HANDLE SCREW, LEVER HANDLE and HANDLE SKIRT.
For toll-free information and answers to your questions, call:
Weekdays 8:00 a.m. to 7:00 p.m. Eastern Time
IN CANADA 1-800-387-0369 (TORONTO 1-416-536-5609)
HOTLINE FOR HELP
1 (800) 442-1902
DISK
O-RING
LOWER
DISK
DISK
O-RING
UPPER
DISK
SHAFT
WASHER
SPRING
SHAFT
O-RING
WASHER
Unscrew ESCUTCHEON HOLDER and remove HOLDER
and ESCUTCHEON.
Unscrew CAP and remove STEM, SPRING and SEALS.
Remove old DIVERTER elements and install new parts.
Replace remaining parts in reverse order.
Product names listed herein are trademarks of American Standard Inc.
© American Standard Inc. 1995
CAP
50321B