Installation
Instructions
TM
1480.500
1480SS.500
T480.500
PRESSURE BALANCED
BATH AND SHOWER
FITTINGS
Thank you for selecting American-Standard...
the benchmark of fine quality for over 100 years.
To ensure that your installation proceeds smoothly-please read these instructions carefully before you begin.
ROUGHING-IN DIMENSIONS
To assure proper positioning in
relation to wall, note roughing-in
dimensions.
FINISHED
WALL
4" REF.
5-1/2"
"SEE ILLUSTRATION
BELOW"
REF.
1-5/8" TO
3-1/4"
1/2" I.P.S.
OPTIONAL TO
FINISHED
FLOOR USUALLY
BETWEEN
65'' AND 78''
SHOWER
FLANGE
SHOWER
ARM
VALVE BODY
WITH STOPS
Certified to comply with ANSI A112.18.1
U.S. Patent No. D400,652
M968395 Rev. 1.1
74"
FOR HEAD
CLEARANCE
18"
OPTIONAL
1" MIN.
TOP OF
TUB RIM
SHR. 1/2" NOM.
COPPER SWEAT
SWEAT
INLETS
TUB 1/2" NOM.
COPPER SWEAT
THREADED
INLETS
SWEAT
INLETS (STOPS)
INLETS
1/2" NOM.
COPPER
SWEAT
TUB 1/2" NOM.
COPPER SWEAT
5-1/8"
REF.
BOTTOM
OF TUB
3-3/8"
INLETS
4-1/16"
5-7/8"
1/2" COPPER
OR1/2" NPT
INLETS
1/2" NOM.
COPPER
SWEAT
SHR.
1/2" NPT
TUB PORT
1/2" NPT
7-5/8"
BATH
1/2" NPT
4"
2"
4-1/16"
INLETS
3-3/8"
INLETS
1/2" NPT
SHR. 1/2" NOM.
COPPER SWEAT
4-1/16"
1/2"
SWEAT
PLUG
THREADED
INLETS (STOPS)
SHR.
1/2" NPT
3-3/8"
TUB PORT
1/2" NPT'
1/2"
NPT
PLUG
VALVE
BODY
PRESSURE
BALANCING
UNIT
5-7/8"
INLETS
1/2" NPT
ADAPTOR AND
MTG. SCREWS
CARTRIDGE
HOT LIMIT
STOP
ESCUTCHEON
SCREWS
CAP
HANDLE
BUSHING
CARTRIDGE
SEALS
CARTRIDGE
SCREW
SET
SCREW
METAL
LEVER
DIVERTER
SPOUT
ESCUTCHEON
HANDLE
For toll-free information and answers to your questions, call:
IN CANADA 1-800-387-0369 (TORONTO 1-905-306-1093)
Product names listed herein are trademarks of American Standard Inc.
© AS America, Inc. 2008
HOT LINE FOR HELP
1-800-442-1902
Weekdays 8:00 a.m. to 6:00 p.m. EST
Weekdays 8:00 a.m. to 7:00 p.m. EST
IN MEXICO 01-800-839-12-00
1
CAUTION
NOTE
When soldering, remove PLASTER GUARD, CARTRIDGES and CHECK STOPS (IF PRESENT). When
finished soldering, flush valve body, replace cartridges, check stops (if present) and plaster guard
to continue installation. Use thread sealant or Teflon tape on threaded connections
Turn off water at MAIN supply. To prevent damage temporarily
remove STOPS when water supply lines are soldered to the manifold.
ROUGHING-IN
See Roughing-in diagram on reverse side.
Connect RISER PIPE to MANIFOLD top outlet marked "SHR".
Connect TUB FILLER PIPE at bottom outlet marked "TUB".
Supply connections are:
1/2" copper sweat for sweat inlets.
1/2" female NPT for threaded inlets.
For proper positioning the finished wall must be within side wall of PLASTER GUARD.
If the valve is installed on a fiberglass or other thin wall application, the PLASTER GUARD can
be used as a support:
Cut a 3" dia. hole in the shower stall.
If stops are used drill two additional 1" holes to allow access to the stops.
Remove PLASTER GUARD, rotate 180˚ so that indicated screw holes fit manifold.
Push CAP on valve, place ESCUTCHEON and attach with screws.
Connect hot and cold water supplies.
For support, use pipe BRACES secured to wooden braces.
With valve turned off, turn on water supplies and check for leaks.
* NOT INCLUDED
IN KIT
BRACE (4) *
RISER
PIPE *
BODY
HOT
PLUG
(NPT)
PLUG
(SWEAT)
TUB FILLER TUBES*
(5/8" O.D. 1/2"
NOMINAL)
SHOWER
COLD
STEM
REMOVE BURRS
FROM TUBE
FLANGE
SHOWER
HEAD
ARM
CARTRIDGE
SCREWS
PLASTER
GUARD
SPOUT
INSTALL TRIM
2
When finished, tiling the wall, remove PLASTER GUARD.
Push on CAP.
Mount ESCUTCHEON with SCREWS.
Install HANDLE by pushing it onto
CARTRIDGE STEM and tightening
SET SCREW from below.
Install SHOWER ARM with FLANGE and SHOWER HEAD.
Install SPOUT.
Check proper operation of HANDLE
and DIVERTER SPOUT.
HOT LIMIT STOP
3
By restricting handle rotation and limiting the amount of hot
water allowed to mix with the cold, the HOT LIMIT SAFETY
STOP reduces risk of accidental scalding. To set the maximum
hot water temperature of your SEVA faucets, all you need
to do adjust the setting on the HOT LIMIT SAFETY STOP.
Remove HANDLE, CAP and HOT LIMIT STOP. Follow "A" or "B"
to adjust maximum discharge temperature.
"A"
PRY FORWARD TO UNLOCK
AND ROTATE COUNTERCLOCKWISE ONE CLICK
PRY FORWARD TO UNLOCK
AND ROTATE CLOCKWISE
"B"
CAP
HANDLE
BUSHING
CARTRIDGE
STEM
ESCUTCHEON
SCREWS
ESCUTCHEON
SERVICE
4
If faucet drips, operate handle several times from "off" to "on".
Do not apply excessive force.
Clogged CARTRIDGE inlets may cause reduced flow in "full
on" hot or cold. To clean inlets, first turn off water supply,
then:
Remove HANDLE, CAP, HOT LIMIT STOP and CARTRIDGE.
Clean inlets and MANIFOLD.
Reassemble CARTRIDGE, alternately tightening screws. Replace
HOT LIMIT STOP , CAP and HANDLE. Check flow.
VALVE
BODY
CARTRIDGE
SET
SCREW
METAL
LEVER
HANDLE
CARTRIDGE
MTG. SCREWS
ADJUSTMENT WHEN
WATER IS TOO HOT
ADJUSTMENT WHEN
WATER IS TOO COLD
MANIFOLD
HOT LIMIT
STOP
CARTRIDGE
SEALS
M968395 Rev. 1.1